background image

®

RF5010 and RF5210

Installation Instructions

Product

Applications

Electrical

Cable detail

Certifications

Warranty

Description

Dimensions

Orientation

Compatibility

       Access Control Systems

       

Proximity Cards

       

Frequency

Indicators

Supervision

Integrated Electric Strike and Proximity Card Reader

See pages 4-6

Non   handed

Open Architecture

Interfaces with Wiegand Protocol Systems 

Supports HID 26   39 Bit Formats

Supports HID 125 kHz Credentials

Red/Green LED and Buzzer

Door Position Switch and Latchbolt Monitor

Frames

      Trim Enhancer

Locks

      

Latchbolts Released*

Environment

      Temperature

      

Humidity

Steel, Aluminum, Wood

Included

Cylindrical

RF5010: Accomodates up to 5/8" Latchbolt

RF5210: Accomodates up to 3/4" Latchbolt

Not Recommended for Outdoor use

32  F  150  F (0  C   65  C)

5   95%, Non-condensing

Reader Module

       Distance to Host

       Recommended Type

Electric Strike Module

       Distance to Power

       Recommended Type

500 ft. Max. 

18  22 AWG (Dependent on Distance) 

Stranded and Shielded 

See Page 3

See Page 3

Compliance

Security

FCC Part 15/IC Class B

ANSI/BHMA 156.31, Grade 1

Lifetime Waranty against defects

in materials and workmanship

RF5010 and RF5210: INTERNAL ANTENNA

HES, Inc.

22630 N. 17th Ave.

Phoenix, AZ 85027

800-626-7590

Reader Module

       Operating Voltage          

                            

    

12VDC +/- 20%

       

Operating Current

Electric Strike Module           

                               

       Operating Voltage                                          

12VDC +/- 10%

      

 Operating Current

                                          240 mA max. @ 12VDC

HID is a registered trademark of HID Corporation.

1

*

Faceplate options accommodate 

various keeper and latchbolt 

actions. For more detail, contact 

HES tech support 

at 800-626-7590

125 mA Max. @ 12VDC

Summary of Contents for Assa Abloy RF5010

Page 1: ...lt RF5210 Accomodates up to 3 4 Latchbolt Not Recommended for Outdoor use 32 F 150 F 0 C 65 C 5 95 Non condensing Reader Module Distance to Host Recommended Type Electric Strike Module Distance to Power Recommended Type 500 ft Max 18 22 AWG Dependent on Distance Stranded and Shielded See Page 3 See Page 3 Compliance Security FCC Part 15 IC Class B ANSI BHMA 156 31 Grade 1 Lifetime Waranty against ...

Page 2: ......

Page 3: ...ire back to the host control panel Check any pertinent information from the access control system installation guide or manual Prepare Frame 9 Attach the faceplate to the hybrid electric strike using the 8 32 screws provided 10 Install the trim enhancer on the hybrid electric strike if needed to cover any extra space 11 Install the hybrid electric strike in jamb cutout using 12 24 screws provided ...

Page 4: ... 8 Radius Corner Faceplate Aluminum Jamb Installations RF5010 or RF5210 with 501 A Faceplate Cutout Template RF5010 and RF5210 INTERNAL ANTENNA 4 32 1 1 4 86 3 3 8 10 3 8 4 7 8 124 4 1 8 105 1 1 4 32 3 3 8 86 R 5 32 4 4 1 8 105 4 7 8 124 3 8 10 RF5010 RF5210 1 13 16 1 11 16 43 47 RF5010 RF5210 1 13 16 1 11 16 43 47 ...

Page 5: ...Cutout Template RF5010 and RF5210 INTERNAL ANTENNA Remove additional material as needed to provide clearance for hybrid electric strike and wires ...

Page 6: ...late RF5010 and RF5210 INTERNAL ANTENNA 6 3 8 10 10 254 3 3 8 RF5010 RF5210 1 13 16 86 1 11 16 43 5 32 4 1 8 3 1 3 8 35 47 R Remove additional material as needed to provide clearance for hybrid electric strike and wires ...

Page 7: ...ving the two screws on the back of the hybrid electric strike Remove Reader Module b Loosen the two 2 56 screws located on the back of the strike module as shown above but do not remove them c Move screws from the top of the hole to fail safe position d Tighten screws Convert Mode e Replace the reader module and tighten the two screws to hold it in place Finish a c Fail Safe B ...

Page 8: ...lt RF5210 Accomodates up to 3 4 Latchbolt Not Recommended for Outdoor use 32 F 150 F 0 C 65 C 5 95 Non condensing Reader Module Distance to Host Recommended Type Electric Strike Module Distance to Power Recommended Type 500 ft Max 18 22 AWG Dependent on Distance Stranded and Shielded See Page 3 See Page 3 Compliance Security FCC Part 15 IC Class B ANSI BHMA 156 31 Grade 1 Lifetime Waranty against ...