background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Version # 341539 1.4 

Differential pressure measuring 
transducer

 

HE 5409 

Operating instructions 

 (Original in German) 

Summary of Contents for HE 5409

Page 1: ...Version 341539 1 4 Differential pressure measuring transducer HE 5409 Operating instructions Original in German ...

Page 2: ...2019 1 2 Chapter 6 Technical data Operating temperature in EX Zone added 12 08 2019 1 3 Chapter 3 1 bilingual type label added Chapter 5 clean gas raw gas corrected 20 01 2020 1 4 Chapter 6 new cable connection M 20 because from now on the housing of HE 5411 is used according to change request 5409xxx from 18 09 2019 Copyrights Copyright 2020 HESCH Industrie Elektronik GmbH Copyrights reserved Con...

Page 3: ...fety instructions 5 2 1 Symbols and general safety instructions 5 2 2 Signal words 5 2 3 Safety during the individual operating phases 6 2 4 Device identification 7 3 Device description 9 3 1 Device view 9 4 Assembly 10 5 Commissioning 12 6 Technical data 14 7 Accessories 15 8 Maintenance and service 16 ...

Page 4: ... thereof the user bears the risk alone Not complying with the above mentioned criteria regarding the intended use will result in expiration of warranty and liability for the device Qualification of personnel Only skilled electricians with sufficient knowledge in electrical engineering shall perform all work at the measuring transducer Device safety The device has been built and tested according to...

Page 5: ...s the level of danger Warning against explosive atmosphere Warning against dangerous electrical current Warning against material damages due to electrostatic loading Warning against material damages Please note Indicates possible malfunctioning and provides instructions for optimal operating conditions 2 2 Signal words DANGER Indicates an immediate danger with high risk which can lead to death or ...

Page 6: ...emoving covers Connection points can be active as well Attention The device shall never be operated despite visible defects Attention Observe the applicable accident prevention regulations for your system such as e g the German Statutory Accident Insurance Association DGUV regulation 3 electrical systems and operating materials during assembly commissioning maintenance and removal of defects Atten...

Page 7: ...ition protection type Protection by smoke restricted housing IIC Explosion group Permitted for gases with an ignition power of 60µJ e g hydrogen T4 Temperature setting Maximum permitted surface temperature 135 C Gc Device protection level Use in zone 2 for gas IP65 Protection type Dust proof and splash water protected Troubleshooting All possibilities of trouble sources at add on devices respectiv...

Page 8: ...a locking bolt The ATEX certification remains valid only if the installation is professionally performed according to the protection type mentioned on the labelling The housing shall only be cleaned with damp cleaning cloths to prevent static loading Cleaning is required to prevent increased dust on the device Operation at live parts in zone 22 only in closed condition Ensure the device housing is...

Page 9: ...onnection Illustration 1 Assembly of hose at push in bulkhead connector A Connect hose Push hose with 6 mm outer diameter into the connection B Release hose 1 Press on the blue locking ring to open the closure 2 Pull the hose out of the connection 1 Press 2 Pull hose Pressure connection and supply line for electrical connection Type label A B ...

Page 10: ...at sources The ambient temperature at the assembly site must not exceed the permitted nominal temperature for operation mentioned in the Technical Data page 14 It is permitted to assemble the device in areas of explosion class EX ATEX zone 22 and 2 The special regulations must be observed see chapter 2 4 device identification on page 7 Dimensions Illustration 2 Reverse side of the housing Scope of...

Page 11: ...ust be opened to the left up to an angle of 105 Optional in addition the housing lid can be closed by 4 screws see accessory list item no 3 on page 15 to protect it from unauthorised access The hinge closure without screws is recommended for a quick service access Illustration 3 Open housing lid to the left Assembling of the device Screws are required for wall mounting Not included in the scope of...

Page 12: ...s not need to be changed A warm up time of 30 minutes must be considered if the zero point must be set The zero point of the measuring transducer is set on 4 mA by the potentiometer B Test switch The output signal can be switched from 4 20 mA to 10 mA by the switch to control the correct connection C Pressure inputs The pressure inputs must be connected via short hoses Attention p raw gas greater ...

Page 13: ...e of the power supply voltage Otherwise the device will be destroyed The connection takes place via spring force terminals for 0 2 1 5 mm conductors The input is bipolar and can be connected as needed The measuring value of the differential pressure corresponds to the power consumption of the device Connection diagram Mains 10 36 V DC HE 5409 bipolar Measuring input 4 20 mA ...

Page 14: ... 9 V 0 02 A Pressure connection Push in bulkhead connectors for 6 mm hose outer diameter Housing Dust protected housing Dimension 113 80 60 W H D Protection type IP 65 Assembly Wall mounting assembly position vertical Connection Spring force terminal Cable screw connector 1 M 20 1 5 N for cable diameters of 6 12 mm Device identification explosion protection Climatic ambient conditions Storage 20 7...

Page 15: ...s Light grey graphite grey bright red ultramarine blue Upon request 3 Screw set 4 pc for optimal screw connection of the housing Factory standard 1412 30 18 10 crosspoint left hand thread B SHR 4 p connector set for HE 54xx and p magnetic valve controls PVC hose Ø i 4 mm Ø a 6 mm 54109999 5 Universal adapter set for push in screw PU hose Ø i 4 mm Ø a 6 mm on Whitworth pipe thread G 54210099 Access...

Page 16: ...gularly to prevent increased dust on the device Disposal Put metals and plastics for recycling Electro and electronic components must be collected separately and disposed accordingly Dispose equipped circuit boards in a professional manner Service HESCH Industrie Elektronik GmbH Boschstrasse 8 31535 Neustadt Germany Telephone 49 5032 9535 0 ...

Reviews: