background image

Manual-WEG-HEB-52-External-Box-Installation-111020

Module HE-B-52-WEG

HE-B-52 Electrical Box

c/w WEG Variable Speed Drive

Installation

For the Installation of:

Part Name

Description

Part Number

HE-B-52 Electrical Box w/ 

110v WEG Controller

Upgrade for 

HE-52

 Air Handlers 

(

110v

 power)

WEG 

Non-Zoning

 Controller, HEB Circuit Board, 

Transformer in 

Galvanized

 Box

40120100052

Small Duct High Velocity Heating, Cooling and Home Comfort Systems

Manufactured By

Summary of Contents for HE-B-52-WEG

Page 1: ...nstallation For the Installation of Part Name Description Part Number HE B 52 Electrical Box w 110v WEG Controller Upgrade for HE 52 Air Handlers 110v power WEG Non Zoning Controller HEB Circuit Board Transformer in Galvanized Box 40120100052 Small Duct High Velocity Heating Cooling and Home Comfort Systems Manufactured By ...

Page 2: ...ing bolts from the air handlers center plate using a 7 16 wrench Fig 3 Large Access Door Fig 1 52 Series Air Handler Fig 2a Fig 3 4 Remove motor blower module from air handler by sliding it out Figs 4a 4b Fig 4a Fig 4b Module HEB 52 WEG Circuit Box Installation 2 6 Fig 2b 5 Unplug motor plug from control board Remove motor ground wire green yellow from the bolt connecting it to the controls plate ...

Page 3: ... 8 9 After all controls have been removed off of the blower housing slide the blower motor module back into the air handler casing Figs 9a 9b Fig 9a Fig 9b Fig 8 10 Replace the two blower bolts securing the blower housing to the center plate using a 7 16 wrench Figs 10 Fig 10 11 Before mounting the new 52 controls upgrade box ensure you connect the male motor plug to the female plug on the bottom ...

Page 4: ...ring is done correctly according to wiring diagram Turn power back on and refer to wiring diagram or to page 30 of the HE B Install Manual for instructions on how to set fan speed airflows Fig 14 Fig 13a Fig 14 Fig 13b Fig 13c 15 After all fan speed airflows have been set the provided coverplate can be screwed on with provided screws to cover the controls section of box Figs 15a 15b 16 With the co...

Page 5: ...RIVE AND ALLOWS YOU TO CHANGE OTHER PARAMETERS ONCE PARAMETER 000 IS SET TO A VALUE OF 005 THE DRIVE IS UNLOCKED THE FAN SPEEDS CAN BE ADJUSTED VIA PARAMETERS 128 129 130 AND 131 00 0 HZ IS THE MINIMUM SPEED 66 0HZ IS THE MAXIMUM SPEED ENSURE ALL OUTLETS ARE OPEN NOTES 1 USE THERMOSTAT FAN SWITCH TO DISABLE ENABLE CONTINUOUS FAN 2 C TERMINAL ON THERMOSTAT COMMON IS NOT NEEDED FOR SOME THERMOSTATS ...

Page 6: ...nergy Saving Products prides itself on Customer Service and provides design services and contractor support For all of your Heating Cooling and Indoor Air Quality needs the Hi Velocity System is the right choice for you Phone 780 453 2093 Fax 780 453 1932 Toll Free 1 888 652 2219 www hi velocity com Hi Velocity HE Z Air Handlers Hi Velocity HE Z Air Handlers Green Green Technology Technology Build...

Reviews: