Specification
3
1
22
21
1
AP
STA
AP
STA
The AP mode is only Supported by device with Wi-Fi function.
©2021 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information
hereinafter are for description and explanation only. The information contained in the Manual is subject to change,
without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision
website (https://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.
Trademarks
and other Hikvision's trademarks and logos are the properties of Hikvision in various jurisdictions. Other
trademarks and logos mentioned are the properties of their respective owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS
HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR
FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING,
AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION
OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING
NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION
SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING
FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION
WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR
ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION,
RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL
NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS
OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES
IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN
RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
This product and - if applicable - the supplied accessories too are marked with "CE" and
comply therefore with the applicable harmonized European standards listed under the RE
Directive 2014/53/EU, the EMC Directive 2014/30/EU, the LVD Directive 2014/35/EU, the
RoHS Directive 2011/65/EU
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as
unsorted municipal waste in the European Union. For proper recycling, return this product to
your local supplier upon the purchase of equivalent new equipment, or dispose of it at
designated collection points. For more information see: www.recyclethis.info
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of
as unsorted municipal waste in the European Union. See the product documentation for
specific battery information. The battery is marked with this symbol, which may include
lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return
the battery to your supplier or to a designated collection point. For more information
see:www.recyclethis.info
Product Information
FCC Information
Please take attention that changes or modification not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operation
2
a
2
b
2
c
2
d
2
1
2.2
K
Ω
N
C
C
Z
C
P
eri
p
heral
S
ecurity Detector
2.2
K
Ω
NO
C
Z
C
Security Control Panel
Security Control Panel
Security Control Panel
P
eri
p
heral
S
ecurity Detector
Dry Contact
AUX+
AUX-
D- D+
AUX+
AUX-
OR
DC-
DC+
D- D+
N.C
N.O
N.C
N.O
N.C
N.O
N.C
N.O
N.C
N.O
N.C
N.O
N.C
N.O
N.C
N.O
Alarm
Lamp
Alarm
Lamp
Alarm
Lamp
Alarm
Lamp
Sounder
RS-485
Lead-acid
Battery
14.3VDC
Power Adapter
Z1
C
Z2
Z3
C
Z4
Z5
C
Z6
Z7
C
Z8
C1 PGM1
AUX+
BELL+
D+
DC+
BAT+
C2 PGM2 C3 PGM3 C4 PGM4 AUX
BELL
D
BAT
DC
2K2
EOL
2K2
EOL
2K2
EOL
2K2
EOL
2K2
EOL
2K2
EOL
2K2
EOL
2K2
EOL
Only for device with
8 on-board zones
Only for device with
8 on-board zones
C1
PGM1
……
2
2
2
3
2
4
Wi-Fi
GPRS
3G/4G
CN1
MAIN
AUX
2
3
......
4
Telephone Module
Telephone Line Cut Of
f Indicator
Power Indicator
Telephone
Line
Telephone
Line
Telephone
Telephone
Z
C
2.2
K Ω
2.
2
K
Ω
Z
C
N
C
N
O
TAM
PER
Note:
The 868 Mhz wireless sounder can be enrolled to the hybrid control panel via
the wireless receiver that is at the address of 9.
CAUTION
SUITABLE FOR MOUNTING ON
CONCRETE OR OTHER
NON-COMBUSTIBLE SURFACE ONLY
Detector
OR
14.3V
Caustic Line
Null Line
GND
UD15861B-F
2.2kΩ
Z
C
Local Zone
Security
Control Panel
8.2kΩ
Local Expanding
Zone
NO C
NO C
2.2kΩ
Z
C
NC
C
8.2kΩ
NC
C
2
e
f
Security
Control Panel
Local Zone
Local Expanding Zone
E N G L I S H
AX Hybrid
Quick Start Guide
Diagram References
Module Installation & Wiring
Set Up
1
2
Telephone Module Wiring
1.
Alarm Input Wiring
2.
Alarm Output Wiring
3.
RS-485 Wiring: Wireless Receiver , keypad, etc,.
4.
Power Supply Wiring
1
a.
N
C Detector
b.
NO
Detector
c.
Unoccupied Zone
d.
Tamper-proof
Note: Power down the control panel before wiring accessories and peripherals.
e.
Dual-Zone Series Connection
f.
Dual-Zone Parallel Connection
Fix the SIM card module (sold separately) and connect the antenna.
2
Fix the telephone module (sold separately).
2
2
Wi-Fi Antenna Wiring
1
2
Network Wiring
2
2
Peripherals/Power Supply Wiring
3
24
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
AP
STA
AP
STA
User Manual
CAUTION:
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Set up via Web Client
For more activation methods ,refer to the User Manual.
1. Enter the device IP address in the web browser.
2. Create a password for admin account to activate the device.
Defacult IP Address:
Mobile broswer(AP mode):192.168.8.1
Network cable connection: 192.0.0.64
D
S-P
HA20
-B
D
S-P
HA
64-B
D
S-P
HA20
-W
2
B
D
S-P
HA
64-W4B
Detector
R
elay out
p
ut
RS-4
8
5
wireless
receiver
Sounder
K
ey
f
ob
Alar
m
in
p
ut
Area
N
o
tifi
ca
ti
on
N
etwork ca
m
era
N/
A
2 (D
S-P
HA20
)
4
(D
S-P
HA
64)
P
rotocol
P
rotocol
W
ired network
Cellular network
W
i
-F
i
/
A
P
S
tandard
N/
A
802.11b
/
g
/
n
U
ser
Tag
/
Card
Op
era
ti
on
te
mp
eratue
Op
era
ti
on
hu
m
idity
W
eight
0.
5
kg (
P
HA20
)
1.7 kg (
P
HA
64)
0.
6
kg
Model
Device
connec
ti
on
UP
to 1
6/56
(
4/
8 on
-
board, 1
6/56
wired
/
wireless
)
F
unc
ti
on
N
etwork
S
u
pp
ort(with 3
G/4G/GPRS
m
odule
)
U
ser
–10 °C to
55
°C (
-4
°
F
to 122 °
F)
12
IS
A
PI
, DC0
9
,
ISUP, CSV-IP, EZVIZ
10M
/
100M
E
thernet
I
nstaller
:
1
;
Ad
m
inistrator
:
1
;
Maintenance
:
1
Op
erator
:
13 (D
S-P
HA20
)
,
45
(D
S-P
HA
64)
O
thers
10% to
9
0% (
N
o condensing
)
S
M
S&P
hone call (with 3
G/4G/GPRS
m
odule
)
Up
to
64
(2
/4
on
-
board, 18
/6
0 wired
/
wireless
)
Up
to 7
1 wired sounders (on
-
board connec
ti
on
)
2 wireless sounders
8
4
(D
S-P
HA20
);
8 (D
S-P
HA
64)
Reset:
After the device is started, hold the reset button for 10 seconds to reset the device.