background image

 

 

 

 

 

 

 

 

 

 

 

DS-TDSB00-EKT/4m  Fall  Detection  Radar 

User  Manual 

Summary of Contents for DS-TDSB00-EKT

Page 1: ...0 DS TDSB00 EKT 4m Fall Detection Radar User Manual...

Page 2: ...CLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION OR LOSS OF DATA CORRUPTION OF SYSTEMS OR LOSS OF DOCUMENTATION WHETHER BASED ON BREACH OF CONTRACT TORT INCLUDING NEGLIG...

Page 3: ...ides additional information to emphasize or supplement important points of the main text Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss per...

Page 4: ...Overview 2 Cables Description 2 Installation Requirements 3 Chapter 2 Software Instruction 4 Device Connection 4 2 1 1 Connection via Wi Fi 4 2 1 2 Connection via RS 485 5 Parameter Settings 5 2 2 2 R...

Page 5: ...re High detection accuracy and low false alarm rate Target tracking Remote and non contact posture detection Small size light and easy installation Specification Refer to the table below for the devic...

Page 6: ...ance Cables Description Refer to the table below for the cables description DS TDSB00 EKT 4m Fall Detection Radar Cables Description Consumption 2 4 W Working Temperature 40 C to 50 C 40 F to 122 F No...

Page 7: ...on the wall at a height of 2 m Make sure that the device is centered horizontally in the detection area and there is no obstruction in front of it Refer to the figures below for the device installatio...

Page 8: ...e radar via Wi Fi Before You Start Power on the radar 12 V Connect your computer to the radar AP hotspot SSID format IRS60_xxxx Default password abcd1234 Use ping command to test if the computer is co...

Page 9: ...radar via the serial port Open the IRS60 3 Radar PC tool Click Connection Settings Select Serial Port Select Port Set BaudRate as 115200 Stop bit as 1 and Data bit as 8 No parity Click Confirm Parame...

Page 10: ...on to view the software version Go to Parameter Settings Delay Time to set the delay time If the radar detects the target person fell and stood up within the set delay time it will not alarm Otherwise...

Page 11: ...off and does not receive wakeup command after powered on again then it will still be standby mode Awake If the radar is powered off the awake mode will be kept after it is powered on again Falling Ind...

Page 12: ...F1 button on the keyboard Menu Page Enter IP Address and Radar Port IP address 192 168 4 1 radar port 6666 Click Connect Click Browse to select the firmware to be upgraded Select Network Segment as t...

Page 13: ...Manual 9 Click Confirm Click Start Update Upgrade Radar Network Configuration You can set the radar network Open IRS60 3 Radar PC tool Press F2 button on the keyboard Enter IP Address and Port IP addr...

Page 14: ...onfiguration Click Connect Set Work Mode as 3 Click Set Set AP Router SSID and AP Router PWD AP Router SSID means the router name AP Router PWD means the router password Set DHCPC as 0 Set IP Netmask...

Page 15: ...Fall Detection Radar User Manual 11 AP SSID means the Wi Fi name AP PWD means the Wi Fi password Set AP Click Set Set Device ID as an integer range 1 to 999999999...

Page 16: ...evice Information Set data report type as 0 Set service IP as Hikcentral Pro service IP Set service PORT as 20000 Set radar debug PORT as 6666 Set radar Passthrough data PORT as 20000 Set report inter...

Page 17: ...0...

Reviews: