background image

Infant Movement Monitor 

5

S

Sensor | Do not use | Sensor

Slot

I

llustration 6

Sensor | Do not use | Sensor

Hanging hook

Blue movement 

indicator light

Red alert 

alarm light

Red low battery 

warning light

On/Off

button

I

llustration 8

Speaker 

Control

Unit

Cable

Cable

Bed/Crib 

base

Control unit holder

I

llustration 5

1

3

2

Ensure you read this user guide before installing and 

using the product.

Babysense

 is a high quality, high sensitivity 

electronic device which must be handled with care: 

• Do not handle roughly, drop or throw.

• Follow the installation instructions carefully to 

ensure that it is installed securely and correctly.

• 

Babysense

 

is not a toy. Do not allow children of any 

age to play with it.

• Do not put any additional baby or pet in the bed.

Babysense

 cannot be used for two infants in one bed. 

• You must undertake the performance test daily of 

the 

Babysense

 monitor (as set out on page 

3).

• Do not operate a vaporiser or ventilator directly 

towards the bed.

• To avoid possible danger from sensor cords, 

ensure that excess cords are pulled back under 

the mattress, secured with the included cable tie 

and are not visible or reachable.

• Install 4 new and identical size AA 1.5 volt batteries, 

preferably alkaline. 

• 

IMPORTANT: 

It is strongly advised that every 

caregiver learn how to give first aid.

Babysense

 monitors and alerts, but cannot prevent 

any type of distress. The responsibility for assistance and 

applying first aid rests on caretakers, who must personally 

check the  baby as often as necessary. 

Babysense

 senses 

movements and motion only, and cannot 

monitor other occurrences. The purpose of the device 

is to alert when stopping or slowing of movement 

occur.

Babysense

 is a unique safety and reassurance system 

which helps give parents peace of mind, alerting if 

movements stop or become irregularly slow, giving 

critical time to intervene. There are a number of 

cautionary steps which are internationally 

recommended for 

SAFE SLEEPING

* Always lay your baby to sleep on his or her back.

* Refrain from smoking near or around your baby.

* Avoid over-heating of the baby's surroundings.

* Do not leave any objects near your baby that can 

cause suffocation.  

Babysense is an addition to these precautions. 

Babysense 

is a movement monitor for home use, 

intended for basically healthy infants up to one year 

of age, and is not to be relied on for use with premature 

or high-risk infants requiring constant medical supervision.

Babysense

 continually detects the baby's motion 

and movements, and will set off a sound and visual

alarm if movement stops for 20 seconds or if 

the monitor detects less than 10 micro-        

movements per minute. The system's non-touch 

sensor pads under the mattress monitor baby's 

movement without restraining him.

1. 

Insert, in accordance with the markings, 4 new and 

identical size AA 1.5 volt batteries, preferable alkaline. 

Close the battery cover.

Note:

 Do not mix old and new batteries.

Note:

 For replacing the batteries, remove the battery 

cover by inserting a flat screwdriver into the opening 

recess (see illustration 7).

Note:

 Please dispose of used batteries in accordance 

with local waste regulations. 

 

2. 

Place the control unit holder on the base of the 

crib or bed and in between two bars as shown in 

illustration 1.

3

.

 Sensor pad installation:

• When using for an infant not yet able to crawl, place 

one sensor pad as shown in illustration 2. Make sure the

sensor is placed  underneath the baby's position in the 

crib.

• When the baby begins to crawl, and is able to move 

onto areas not "covered" by a single sensor pad, attach 

the second sensor and place the two sensors  as shown 

in illustration 2.  

PLEASE NOTE: 

The sensors shall be placed with the 

marking “THIS SIDE UP” facing upwards. 

Warnings

Principal Of Operation 

Installation

Please note

7. Should the design of the crib/bed not allow proper 

installation with the control unit holder, please use the 

optional hanging hook (see illustration 6) and hang the 

control unit from the bottom edge of the crib.

 

8. Press the control unit holder or hanging hook firmly 

into the slot in the back of the control unit (see 

illustration 5 and 6).

9.

 

Place the mattress firmly on top of the sensor 

pads. If the mattress cannot be in contact with the 

sensor pads, or if the bed base is soft, padded or 

contains springs, place extra plywood on the bed 

base, place the sensor pads on the plywood and 

place the mattress firmly on top (see section 4). 

  

IMPORTANT

: To avoid possible danger from sensor 

cords, ensure that excess cords are pulled back 

under the mattress, secured with the included cable 

tie and are not visible or reachable.

See illustration 8 for layout of control unit featuring:

• On/Off button. 

• Blue movement indicator light. 

• Acoustic and visual red alarm light. 

• Low battery red warning light. 

Babysense

 is ready for operation and use once the 

installation is complete. To operate, follow the 

below instructions:

• Place your baby in the crib/bed.

• 

Press the On/Off button to turn on the control unit.

• Red lights switch on briefly and a double click 

sound is heard. 

• When any movement is sensed, the blue light 

flashes. 

User Guide

4. When using a crib/bed equipped with spring 

base, place extra wooden board (plywood) under 

each sensor pad, as shown in illustration 3. The 

recommended size of the board is at least 17’’ x 11’’                        

and 1/2’’ thick.

5. 

Pass the cord(s) of the sensor pad(s) through 

special openings in the holder. (see illustration 4)

6. Attach end(s) of the cord(s) to the outlets

marked "SENSOR" on the back of control unit

(see illustration 6 and 7). When using one sensor

pad, attach to either “SENSOR” outlet.

PLEASE NOTE:

 Do not attach any cable to the 

blocked socket, marked "DO NOT USE"

Babysense

 is a highly  sensitive device which 

monitors a baby's motion and movements through 

the mattress during sleep. There are two main 

causes of malfunction - technical malfunctions and 

malfunctions due to environmental factors.

 

In order to minimize technical problems, follow 

installation and operation instructions carefully.

Due to the high sensitivity of 

Babysense

, it can be 

influenced by fans, wind, air conditioning, 

vibrating household sources and so forth. Such 

environmental effects could be picked up by the 

sensors on a similar level to that of slight movements, 

thus preventing or delaying alarm activation.

 

Do not conduct the performance test by picking up 

baby out of bed and waiting for the alarm to sound 

• The performance test should be conducted 

while the baby is not in bed. 

• Turn the unit on and take two steps back from bed. 

• Ensure the alarm goes off within 20 seconds 

(due to absence of movement).

• The alarm may sound with or without 

preliminary ticking. 

• Check the alarm can be heard in all locations 

throughout  the home or place of care.

• If the alarm does not sound within 20 

seconds refer to the troubleshooting at page 4.

• The performance test must be conducted daily.

 

 

Isolated cases of false alarms are possible. Check if caused 

by faulty connection of the sensor pad(s) to the control 

unit, connection of only one sensor pad when the  

baby  is can move off the immediate area, connection 

of two  sensor pads far apart from each other when the  

baby is not crawling yet, or failure of the sensor pads to 

be directly against the mattress.

 

In case of false alarms, refer  to  the troubleshooting 

guide. If the problem cannot be solved, please 

contact your nearest 

BABYSENSE

 representative.

 

Sensor | Do not use | Sensor

Slot

Battery 

cover 

Blocked socket

DO NOT USE

“Sensor”

sockets

I

llustration 7

Opening 

recess

Speaker 

Layout of control unit

Operation

Testing Operation

Technical malfunction

Environmentally caused malfunction

Conduct this performance test daily

False alarms

Cables

I

llustration 4

Control unit 

holder

I

llustration 1

Control unit holder

Cables

Sensor

Sensor

Sensor 

pads

(Under mattress)

Control unit

I

llustration 2

Top crib/bed view

For babies not 

yet able to crawl

For crawling babies

Top crib/bed view

• Acoustic and visual red light alarms are activated 

if the baby's movement stops or slows significantly.

• If the red low-battery warning light flashes, 

replace all batteries as soon as possible. If in 

addition clicking is heard, all batteries must be 

replaced immediately. 

• Turn off by pressing the On/Off button before 

taking your baby out of crib/bed.      

Plywood

I

llustration 3

Sensor

Sensor

Spring base

Top crib/bed view

Reviews: