background image

INSTALLATION AND OPERATION MANUAL

MANUAL DE INSTALACIÓN Y FUNCIONAMIENTO

INSTALLATIONS- UND BETRIEBSHANDBUCH

MANUEL D’INSTALLATION ET DE

FUNCTIONNEMENT

MANUALE D’INSTALLAZIONE E D’USO

MANUAL DE INSTALAÇÄO E DE

FUNCIONAMENTO

BRUGER- OG MONTERINGSVEJLEDNING

INSTALLATIE- EN BEDIENINGSHANDLEIDING

HANDBOK FÖR INSTALLATION OCH ANVÄNDING

ÅÃ×ÅÉÑÉÄÉÏÅÃÊÁÔÁÓÔÁÓÇÓÊÁÉËÅÉÔÏÕÑÃÉÁÓ

PC-P5H

REMOTE CONTROLLER

ENGLISHENGLISH

ESP

AÑOL

DEUTCH

FRANÇAISFRANÇAIS

IT

ALIANO

POR

TUGUES

DANSKDANSK

SVENSKASVENSKA

NEDERLANDSNEDERLANDS

Do not perform installation work, without referring to our installation manual.
No realice la instalación de este equipo, sin antes consultar este manual de instalación.
Bei der Installation unbedingt die Hinweise in der Installationsanleitung beachten.
Consulter notre manuel avant de réaliser une quelconque installation.
Realizzare l’installazione, seguendo quanto indicato in questo manuale.
Nao inicie os trabalhos de montagem, sem consultar o nosso manual de montagem.
Udfor ikke installationsarbejder uden forst at donsultere vores vejledning.
Voer geen enkele handeling uit om de apparatuur alvorens deze hadleiding te hebben
doorgelezen.
Utför inte nagra installationsarbeten utan att först läsa var installationsmanual

Ìçí Þóåôå óôçí åãêáôÜóôáóç, ÷ùñßò ðñéí íá Ý÷åôå óõìâïõëåõèåß áõôo ôï åã÷åéñßäéï åãêáôÜóôáóçò

Summary of Contents for PC-P5H

Page 1: ...ng to our installation manual No realice la instalación de este equipo sin antes consultar este manual de instalación Bei der Installation unbedingt die Hinweise in der Installationsanleitung beachten Consulter notre manuel avant de réaliser une quelconque installation Realizzare l installazione seguendo quanto indicato in questo manuale Nao inicie os trabalhos de montagem sem consultar o nosso ma...

Page 2: ......

Page 3: ...uerte ADVARSEL Farer eller farlig brug som KAN resultere i alvorlig personskade eller dødsfald WAARSCHUWING Gevaren of onveilige praktijken die ernstig persoonlijk letsel of de dood tot gevolg KUNNEN hebben VARNING Risker eller osäkra tillvägagångssätt som KAN leda till svåra personskador eller dödsfall ΠΡΟΕΙ ΟΠΟΙΗΣΗ Κίνδυνοι ή επικίνδυνες πρακτικές οι οποίες ΜΠΟΡΕΙ να έχουν ως αποτέλεσµα σοβαρές ...

Page 4: ......

Page 5: ... outdoor unit controller and cable within approximately 3 meters from strong electromagnetic wave radiators such as medical equipment In case that the controller is installed in a place where there is electromagnetic wave radiation shield the controller and cables by covering with the steel box and running the cable through the metal conduit tube In case that there is electric noise at the power s...

Page 6: ...g bracket push and turn the screw driver and remove the controller from the holding bracket 2 Connection of cable Connect the accessory cable to the fielded cable by soldering 3 Attach the controller to the holding bracket and connect the cable as follows In Case of Exposing Remote Control Cable More than 50mm Figure seen from Bottom Side Groove Part Screw Driver Approx 6mm Insulate the connecting...

Page 7: ...TANDARD WIRING ÕATTENTION Attach the ring core black accessory when installing the unit Insert the controller cable into the ring core 2 turns as shown in the left figure before connecting to the terminal board If wiring is 0 75mm 2 it is necessary to peel the outside cover Fix the cable by using the band accessory Controller Ring core Band Controller cable M4 Screws Field Supplied Insert the conn...

Page 8: ...g the shield to Earth at the electrical box side the max total length is 200m Optional Accessory Cable The cables 2x0 75mm 2 twist wire of different length are prepared as an option which are fitted with connectors Remote Control Cable Option Cable Ref Cable Model Length m 7E790211 PRC 10E1 10 7E790212 PRC 15E1 15 7E790213 PRC 20E1 20 7E790214 PRC 30E1 30 Standard shielded cable 2x0 75mm Solderles...

Page 9: ...ompletion of the automatic address setting requires 3 to 5 minutes after turning ON the power supply The total number of the connected units is indicated on the liquid crystal display In case that the indicated number is not correct some abnormalities exist incorrect wiring the electric noise etc Turn OFF the power supply and correct the wiring after checking the following points Do not repeat tur...

Page 10: ...temperature is indicated on the display 3 Select one of the fan speed by pressing the switches The set fan speed is indicated by the green LED 4 Press the Switch The red LED turns ON To Stop 1 Press the Switch Air Conditioning is stopped and all the LEDs are turned OFF In order to restart press the switch NOTES Swing Louver Setting is not available Select by Central Station or other remote control...

Page 11: ...or Setting Mode No ºC Press the Switch and select the operation mode Main Remote Control Switch Sub Remote Control Switch When this setting is changed cut off the power supply of all indoor units after returning the normal mode Press the and Switch simultaneously for more than 3 seconds Change to the function setting mode Normal mode When unit is not operating Setting Mode No ºC Press the Switch a...

Page 12: ...arm Code is indicated as shown in the right figure Model Code Model UTOPIA DC Inverter SET FREE The other code Not Used Refrigerant Cycle Number Indoor Unit Number After 1 second ºC Model Code Alarm Code Total Number of connected units A G indicates 10 16 ºC ºC After 1 second After 1 second ...