background image

above 50mm

above 100mm

about 400mm

about 300mm

must not bend

above 100mm

2,300mm or more

1

2

Maximum pipe length 20m

Minimum pipe length 4m

above 200mm

above 700mm

above 50mm when
installed on the
ceiling of balcony

(

)

above 100mm

above 100mm

give clearance as
wide as possible

6

4

3

Plug

5

above 200mm

SPLIT UNIT AIR CONDITIONER

INSTALLATION MANUAL

Indoor Unit

Outdoor Unit

RAS-X10CZ

RAC-X10CZ

(    mark is tool exclusive use for R410A)

● 

+  –  Screwdriver 

  

 Measuring Tape 

  

● 

 Knife   

 Saw

Pipe Cutter 

 Hexagonal Wrench Key (

 4mm)

Power Drill (ø 65mm ~ ø 80mm)

Vacuum Pump

Pliers or Wrench  

 Torque Wrench

Vacuum Pump

Adaptor 

 Flare Tool 

 Gas Leakage Detector

 Manifold Valve 

 Charge Hose

Carefully read through the procedures of proper
installation before starting installation work.

The sales agent should inform customers regarding
the correct operation of installation.

Tools Needed For Installation Work

SAFETY PRECAUTION

Read the safety precautions carefully before operating the unit.

The contents of this section are vital to ensure safety. Please pay special attention to the following sign.

WARNING  ........  Incorrect methods of installation may cause death or serious injury.
CAUTION  .........  Improper installation may result in serious consequence.

Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating
the unit as described in the user’s guide.

!

!

WARNING

!

CAUTION

!

A circuit breaker or fuse (16A time delay) must be installed. Without a circuit breaker or fuse the danger of electric shock  exists.
A main switch with a contact gap of more than 3mm has to be installed in the power supply line to the outdoor unit.

Do not install the unit near a location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it.

Please ensure smooth flow of water when installing the drain hose.

Piping shall be suitable supported with a maximum spacing of 1m between the supports.

Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you do the installation work yourself.

Please observe the instructions stated in the installation manual during the process of installation. Improper installation may cause water leakage, electric shock and
fire.

Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may collapse and impose danger.

Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing with the electrical work. Use power
cables approved by the authorities of your country.

Be sure to use the specified wire for connecting the indoor and outdoor units. Please ensure that the connections are tight after the conductors of the wire are inserted
into the terminals. Improper insertion and loose contact may cause over-heating and fire.

Please use the specified components for installation work. Otherwise, the units may collapse or water leakage, electric shock and fire may occur.

Be sure to use the specified piping set for R-410A. Otherwise, this may result in broken copper pipes or faults.

When installing or removing an air conditioner, only specified refrigerant (R410A) shall be allowed, do not allow air or moisture to remain in the refrigeration cycle.
Otherwise, pressure in the refrigeration cycle may become abnormally high so that a rupture may be caused.

Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with fire, a poisonous gas may occur.

After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks into the room, coming into contact with
fire in the fan-driven heater, space heater, etc., a poisonous gas may occur.

Unauthorized modifications to the air conditioner may be dangerous. If a breakdown occurs please call a qualified air conditioner technician or electrician. Improper
repairs may result in water leakage, electric shock and fire, etc.

FOR SERVICE PERSONNEL ONLY

THE CHOICE OF MOUNTING SITE 

 (Please note the following matters and obtain permission from customer before installation).

WARNING

!

The unit should be mounted at stable, non-vibratory location which
can provide full support to the unit.

WARNING

!

The Outdoor unit must be mounted at a location which can sup-
port heavy weight. Otherwise, noise and vibration will increase.

CAUTION

!

No nearby heat source and no obstruction near the air outlet is
allowed.

The clearance distances from top, right and left are specified in
figure below.

The location must be convenient for water drainage and pipe
connection with the Outdoor unit.

To avoid interference from noise please place the unit and its
remote controller at least 1m from the radio, television and inverter
type fluorescent lamp.

To avoid any error in signal transmission from the remote controller,
please put the controller far away from high-frequency machines
and high-power wireless systems.

The installation height of indoor unit must be 2.3m or more.

CAUTION

!

Do not expose the unit under direct sunshine or rain. Besides,
ventilation must be good and clear of obstruction.

The air blown out of the unit should not point directly to animals
or plants.

The clearances of the unit from top, left, right and front are specified
in figure below. At least 3 of the above sides must be open air.

Be sure that the hot air blown out of the unit and noise do not
disturb the neighbourhood.

Do not install at a location where there is flammable gas, steam,
oil and smoke.

The location must be convenient for water drainage.

Place the Outdoor unit and its connecting cord at least 1m away
from the antenna or signal line of television, radio or telephone.
This is to avoid noise interference.

Do not install outdoor unit facing strong wind direction. It may
damage the fan motor.

INDOOR UNIT

Figure showing the Installation
of Indoor and Outdoor Unit.

OUTDOOR UNIT

Direction of Piping

Dimension of Mounting Stand

of the Outdoor unit

(unit : mm)

There are 4 directions
allowed, namely, horizontally
perpendicular to the unit,
vertically down from right,
horizontally out from right and
horizontally out to left.
Don’t form the piping
downward at the left of the unit.

The difference in height
between the indoor and
outdoor unit should be
kept max 10m.

The connecting pipe, no
matter big or small,
should all be insulated
with insulation pipe and
then wrapped with vinyl
tape. (The insulator will
deteriorate if it is not
wrapped with tape).

The connection of insulated
drain hose.

Please use insulated drain
hose for the indoor piping
(commercial product).

The indoor piping should be
insulated with the enclosed
insulation pipe. (If the
insulator is insufficient,
please use commersial
products).

inner diameter ø 16mm

Be sure to
completely
seal any
gap with
putty.

Connection

Horizontally
perpendicular
to the unit

mounting stand

500

102

45

282

9

300

9

30

12

30

16

20

!

CAUTION

The installation height
of indoor unit must be
2.3m or more.

Installation of Hanger, Wall Penetration and Installation of Protection Pipe

1

CAUTION

!

The draining of the water container inside the indoor unit can be done from the left.
Therefore the hanger must be fixed horizontally or slightly tilted towards the side of
drain hose. Otherwise, condensed water may overflow the water container.

Direct Mounting On The Wall

Please use hidden beams in the wall to hold the hanger.

Wall Penetration and Installation of Protection Pipe

Drill a ø 65mm hole on
wall which is slightly tilted
towards the outdoor side.
Drill the wall at a small
angle.

Cut the protection pipe
according to the wall
thickness.

Empty gap in the sleeve
of protection pipe should
be completely sealed
with putty to avoid
dripping of rain water into
the room.

Procedures of Installation and Precautions

Procedures to fix the hanger.

1. Drill holes on wall.

2. Push plug into the holes.

3. Fix the hanger on wall

(As shown below)

(As shown below)

with 4.1 x 32 screw
(As shown in figure below)

Procedures to fix the holder of remote control.

1. Drill holes on wall.

2. Push plug into the holes.

(As shown below)

(As shown below)

   Installation of the Indoor Unit

2

VERTICALLY DOWNWARD PIPING

  Preparation

Connect connecting cord.

Pull out the pipe, connecting cord and drain hose.

  Installation

The upper part of the Indoor unit is hanged on the hanger.

The projection at the lower part of the Indoor unit is hooked onto the hanger.

Please pull the lower part of
the Indoor unit outwards to
check if the unit is hooked
onto the hanger. Improper
installation may cause
vibration and noise.

!

CAUTION

HORIZONTAL PIPING

  Preparation

Change of Drain Hose and Installation Procedures.

Exchange the location of drain hose and drain cap during horizontal piping as shown in
figure below. Be sure to plug in the drain hose until the insulating material folds upon itself.

Please use pliers to pull out the drain cap.
(This is an easier way to remove the drain cap).

INSTALLATION OF REFRIGERATING PIPES AFTER CONNECTION

The refrigerating pipes should be adjusted to fit into
the hole on the wall and then ready for further
connection.

The terminals of 2 connected pipes must be covered
with insulator used for terminal connection. Then the
pipes are wrapped with insulation pipe.

Connect the connecting cord after removing electrical
cover. (Refer to “CONNECTION OF POWER CORD”)

After adjustment, fit the connecting cord and pipes
into the space available under the indoor unit. Use
holder to hold them tight.

!

CAUTION

The rubber strap used for
fixing the insulator should
not be tied with great force.
Otherwise, this will damage
heat insulation and causes
water condensation.

Holder can be attached at the either of 2 places.
Please select the easier position.

THE CONNECTION OF REFRIGERATING PIPE DURING THE
INSTALLATION OF INDOOR UNIT

Preparation To Install Refrigerating Pipes

!

CAUTION

Please fix in the plastic core
after flaring to avoid plastic
chips entering the pipes.

CAUTION

!

You are free to choose the side (left or right) for the installation of drain
hose. Please ensure the smooth flow of condensed water of the Indoor
unit during installation. (Carelessness may result in water leakage.)

!

CAUTION

Be sure that the
drain hose is not
loosely connected
or bend.

Be sure that the wire is not
in contact with any metal
in the wall. Please use the
protection pipe as wire
passing through the hollow
part of the wall so as to
prevent the possibility of
damaged by mouse.
Unless it seals completely,
any air with high humidity
flows from outdoor and
any dew may drop.

!

WARNING

The refrigerating pipes and connecting cord
transform and are attached.

The end of the refrigerating pipes are at locations
marked with “ 

  ” symbol.

   Installation of Drain Hose

3

  Installation

Hang the Indoor unit onto the hanger. Use the temporary stand
at the back of the Indoor unit to push its lower part 15cm
forwards.

Place the drain hose through the hole on the wall.

Wrap the refrigerating pipes with insulation pipe after
connecting refrigerating pipe.

Connect the connecting cord after removing electrical cover.
(Refer to “Connection of Power Cord”)

After adjustment, the connecting cord and refrigerating pipes
are placed into the space available under the Indoor unit.

The projection of Indoor unit must hook to the hanger.

INDOOR UNIT

<

IA619: A 

>

32mm

20mm

ø

4.8mm

ø

4.4mm

Wall

1   Hanger

2   Screw

Plug

Wall

above 50mm

Ceiling

4.1 x 32 Screw

Wall

Remote

Control

Holder

5   Screw

Plug

3

Sleeve of
protection
pipe

WALL

Protection
pipe

Seal with
putty

Seal with
putty

2 ~ 5mm

Outdoor

Indoor

Connecting cords, pipe and
drain hose must be laid
together with Vinyl tape.

Lift the body
of the unit
upwards and
then force it
downwards.

Hanger

Refrigerating
Pipe

Protection
Pipe

Drain Hose

Connecting 
Cord

Hanger

1

Projection

2

[Push] mark positions

!

CAUTION

Condensed water may leak out if not inserted properly.

HORIZONTAL & DOWNWARD PIPING – MAKING OPENINGS

During horizontal or downward piping, use a knife to cut
openings as shown in figure. Then smoothen the edges of
openings with a file.

Turn the piping while holding down the lower
portion of pipe-support by hand.

Drain hose

Drain cap

Drain cap

Please insert
until here

Drain hose

Please insert
until here

Pipe 
support

Pull up the pipe after
bending downward

Openings

Pipe

Connecting
cord

Drain hose

Insulation pipe (must be wrapped with
vinyl tape at every 120mm).

Pipe

Rubber strap tied with great force

below
5mm

Please bend at a small
radius to form an arc

0.85m

about 15cm

Hook

Projection

Protection pipe

Connecting cord

Holder

Connected 
section

Drain hose

HITACHI

Heat insulation pipe

Connecting
cord

Refrigerating pipe

Pull this to the front
during the connection
of refrigerating pipes
to ease task.

Bending
upwards

Condensed
water pond

Ditch

Condensed
water pond

Names of Indoor Components

Hanger

Qty

No.

Item

1

1

Screw for holder of
Remote Controller

( 3 . 1 x 1 6 )

AAA Size Battery

Holder for Remote
Controller

( 4 . 1 x 3 2 )

Remote Controller

Purifying Filter

2

6

3

1

4

2

5

2

6

7

1

1

Screw for Hanger

125mm

45mm

200mm

60mm

80mm

780mm

125mm

280mm

45mm
115mm

450mm

Level

Hanger

Hole for pipe

Weight

Mark

Line

Please use more
than 4 screws.

Screw for Hanger

HOW TO REMOVE INDOOR UNIT

Push up the (PUSH) sections at the
bottom of the indoor unit and pull the
bottom plate towards you. Then the
claws are released from the stationary
plate.
(The (PUSH) sections are indicated by
2 arrows in the right figure)

In case the pipe length is more than
8m, add refrigerant R410A at 15 gram
per every meter exceeds. However,
pipe length shall not exceed 20m.

!

CAUTION

8

1

Hole cover sticker

HFC

R410A

This air conditioner uses new refrigerant HFC (R410A).

The basic installation work procedures are the same as conventional refrigerant (R22) models.
However, pay careful attention to the following points:

(1) Since the working pressure is 1.6 times higher than that of conventional refrigerant (R22) models, some of the piping and installation and service tools are special.

Especially, when replacing a conventional refrigerant (R22) model with a new refrigerant R410A model, always replace the conventional piping and flare nuts with the
R410A piping and flare nuts.

(2) Models that use refrigerant R410A have a different charging port thread diameter to prevent erroneous charging with conventional refrigerant (R22) and for safety. Therefore,

check beforehand. [The charging port thread diameter for R410A is 1/2 UNF 20 threads per inch.]

(3) Be more careful that foreign matter (oil, water, etc.) does not enter the piping than with refrigerant (R22) models. Also, when storing the piping, securely seal the

openings by pinching, taping, etc.

(4) When charging the refrigerant, take into account the slight change in the composition of the gas and liquid phases, and always charge from the liquid phase side whose

composition is stable.

(EN1) INS RAS-X10CZ

18/12/09, 9:29

1

Summary of Contents for RAC-X10CZ

Page 1: ...wise condensed water may overflow the water container Direct Mounting On The Wall Please use hidden beams in the wall to hold the hanger Wall Penetration and Installation of Protection Pipe Drill a ø 65mm hole on wall which is slightly tilted towards the outdoor side Drill the wall at a small angle Cut the protection pipe according to the wall thickness Empty gap in the sleeve of protection pipe s...

Page 2: ...e core Hexagonal Wrench Key Cap of valve head Cap of valve head Sleeve of protection pipe Putty Putty Insulation material for pipe connection Outer dia of pipe 6 35 1 4 9 52 3 8 12 7 1 2 6 35 1 4 9 52 3 8 12 7 1 2 Valve head cap Torque N m kgf cm 13 7 18 6 140 190 34 3 44 1 350 450 44 1 53 9 450 550 19 6 24 5 200 250 19 6 24 5 200 250 29 4 34 3 300 350 12 3 15 7 125 160 Small dia side Large dia si...

Page 3: ...r atau senget sedikit ke sebelah salur air Kalau tidak air terkondesasi mungkin akan mengalir keluar Kawasan dinding yang sesuai untuk pemasangan Sila pasangkan plat pemasangan pada tiang dalam dinding Menebuk lubang pada dinding dan pemasangan salur pelindung Semasa menebuk lubang ø 65 mm condongkan ke bawah sedikit di sebelah dinding luar kekalkan kecondongan ini Keratkan salur pelindung mengiku...

Page 4: ...n plag yang baru Penggunaan plag yang lama mungkin akan menyebabkan kemalangan atau kerosakan kerana terdapat kelonggaran Sila tarik dan masukkan plag ke dalam soket 2 3 kali supaya plag boleh masuk ke dalam soket sepenuhnya Tolong lebihkan sedikit kepanjangan kabel untuk mengelakkan tindakan daya luar ke atas plag serta sentuhan di antara plag dengan soket adalah sempurna Jangan pakukan kabel ele...

Reviews: