HomeGrid Stack’d Series Installation Guide 

 

1.

 

Safety Precautions 

It is very important to read the user manual carefully before installing or using battery. Failure to 

do so or to follow any of the instructions or warnings in this document can result in electrical 

shock, serious injury, or death. Installing the battery incorrectly can permanently damage battery 

or rendering it inoperable. 
 

 

 

 

 

 

 

1.1.

 

General warnings 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Any internal lithium ion cell material such as electrolyte or powder on the skin or in the 

eyes must be flushed with plenty of clean water immediately. Then seek medical 

assistance. Any material spilled on clothing should be rinsed out with water. 

Explosion and fire hazard. Terminals of the Li-ion Battery are always alive; therefore, do not 

place items or tools on the Li-ion Battery. Avoid short circuits, over discharges and high 

charge currents. Use insulated tools. Do not wear any metallic items such as watches, 

bracelets, etc. In case of fire; you must use a type D, foam or CO2 fire extinguisher. 

Do not open or dismantle the battery. Electrolyte is very corrosive. In normal 

working conditions you will not have any contact with the electrolyte. If the battery 

casing is damaged do not touch the exposed electrolyte or powder because it is 

corrosive. 

 

For more information about this product, please visit the official website: 

http://www.homegridenergy.com

 

 

Work on a Li-ion Battery should be carried out by qualified personnel only. 

While working on the Li-ion Battery wear protective eyeglasses and clothing. 

Li-ion batteries are heavy. If involved in an  traffic accident they can become a 

projectile! Ensure adequate and secure mounting and always use suitable handling 

equipment for transportation. 

Handle with care because this lithium ion battery is sensitive to mechanical forces shock. 

Do not expose bare cables outs, all the battery terminals must be disconnected for 

 

Summary of Contents for Stack'd Series

Page 1: ...gh charge currents Use insulated tools Do not wear any metallic items such as watches bracelets etc In case of fire you must use a type D foam or CO2 fire extinguisher Do not open or dismantle the battery Electrolyte is very corrosive In normal working conditions you will not have any contact with the electrolyte If the battery casing is damaged do not touch the exposed electrolyte or powder becau...

Page 2: ...ject Do not power wash the battery or get wet Direct sunlight must be avoided Do not use a damaged battery Please contact the supplier within 24 hours if there is something abnormal Do not expose battery to flammable or harsh chemicals or vapors Do not paint any part of battery include any internal or external components Do not place any foreign objects into any part of battery The warranty will b...

Page 3: ...k Battery Modules Remove black sticker on bottom of battery Module Stack battery Module onto Base then remove both side covers per module Repeat with remaining modules Dial correct addresses on modules 1 8 with 1 being at the top and 8 being at the bottom ...

Page 4: ... OFF Set to the slave Pack 6 7 ON ON ON OFF OFF OFF Set to the slave Pack 7 8 OFF OFF OFF ON OFF OFF Set to the slave Pack 8 Turn on Modules Place Controller main BMS on top of system Make sure Controller is off Then remove top and side covers from Controller Install included BUS bars onto Controller terminals Connect power cables 4 0 to BUS bars and inverter Create comm cable for inverter communi...

Page 5: ...ct to Victron inverter Connect to the Growatt inverter Connect to the Sofar inverter Connect to the Solis inverter Connect to the Goodwe inverter Connect to the Sermatec inverter Connect to the Must inverter Connect to the GreenCell inverter ...

Page 6: ... Detect of modules in system Set all inverter switches on Controller Main BMS to On Power on Controller to detect modules Controller display will then show the of modules detected Power off Controller Detect Inverter Protocol Set inverter switches to correct inverter being used See chart below Power on Controller ...

Page 7: ... OFF ON ON OFF OFF OFF Victron_color_control 7 ON ON ON OFF OFF OFF SMA_LV 8 OFF OFF OFF ON OFF OFF Sermatec_LV 10 OFF ON OFF ON OFF OFF Growatt_SPF 11 ON ON OFF ON OFF OFF Li_PLUS 12 OFF OFF ON ON OFF OFF Schneider_Gateway 13 ON OFF ON ON OFF OFF SOL ARK_LV 18 OFF ON OFF OFF ON OFF Growatt_SPH SPA 27 ON ON OFF ON ON OFF GreenCell 29 ON OFF ON ON ON OFF Must 62 OFF ON ON ON ON ON Find Address used...

Page 8: ...ckets for the battery module into a long strip and mount them in the middle of the left hand side of the system Re install all covers on Modules and Controller from bottom to top Complete See next page for Parallel Installation ...

Page 9: ...ke effect See below for switch settings Address Coding Master Address Dial Code Switch Position Definition 1 2 3 4 5 6 1 ON OFF OFF OFF NG NG The host computer can monitor the operation of other systems by setting the main package 2 OFF ON OFF OFF NG NG Set to Pack2 3 ON ON OFF OFF NG NG Set to Pack3 4 OFF OFF ON OFF NG NG Set to Pack4 5 ON OFF ON OFF NG NG Set to Pack 5 6 OFF ON ON OFF NG NG Set ...

Page 10: ...master is connected via communications to inverter power on all slaves Set master inverter switch to detect of systems in parallel 62 OFF ON ON ON ON ON Find Address used when more than one system is connected Turn on Master Controller to detect total of Stack d systems Master Controller will then display the of systems in parallel Once detected turn Master off change inverter switches on Master t...