background image

S

CW

DL

READ IT

 

OR

 

WATCH IT

Read instructions or watch easy-to-follow video. 

Scan QR code or visit bit.ly/2FAzqcD

45366 (12IN.), 45367 (18IN.), 45368 (24IN.), 

45369 (36IN.), 45370 (48IN.)

DIRECT WIRE 

LED LIGHT FIXTURE

SAVE THESE INSTRUCTIONS IN A LOCATION CLOSE TO YOUR CABINET 

SO YOU CAN REFER TO THEM AT A LATER TIME.
CAUTION: DO NOT USE POWER TOOLS TO SECURE SCREWS, AS 

THERE IS A RISK OF STRIPPING THE SCREWS.
DO NOT USE WITH A DIMMING CIRCUIT OR ANY OTHER 

ELECTRONICALLY SWITCHED CONTROL.
DO NOT EXCEED THE MAXIMUM CONNECTED UNITS INDICATED ON 

THE POWER ADAPTER/LED DRIVER.

PACKAGE CONTENTS

INSTALLATION PROCEDURE FOR DIRECT  

WIRE LIGHT FIXTURE

Note: 

For kitchen installations, the recommended mounting for the 

dimmable LED light fixture is near the front lip of your under cabinets as 

shown in the illustration (

see Figure 1

). The LEDs will face the front of 

the cabinet. This provides the best light distribution across a countertop.

1.  Consult a local licensed electrician or electrical  

 

contractor if you are not sure about the installation.

2.  Ensure that electricity is TURNED OFF at the main 

 

circuit breaker or fuse box. DO NOT ATTEMPT TO  

 

INSTALL FIXTURE WITH THE POWER ON.

3.  Select a suitable dry mounting location (for indoor  

 

use only). Make sure the mounting surface is capable of  

 

supporting the fixture.

4.  Remove the lens/diffuser by lightly pulling the rear edge  

 

toward the front and upward. The lens/diffuser should  

 

pop out easily.

5.  Remove the cover/housing by unscrewing the screws  

 

located on the top of the cover. Firmly push forward on  

 

the bottom front of the housing to unlatch it from the  

 

catch points. The hardware kit is inside the wiring cavity.

6.  Ensure that there is adequate space to install the  

 

fixture by using the base as a mounting template. While  

 

the base is held in place, mark location for pilot holes  

 (

see Figure 2

).  

7.  Choose a suitable knock-out location from those  

 

provided on the fixture. Remove the knock-out with  

 

a screwdriver (not included).

FIGURE 1

CABINET

COUNTER TOP

W

ALL

SW

CW

DL

A

B

C

A. 

Light Fixture x1

B. 

M4 x 12mm short mounting  

screw x2

C. 

Strain relief assembly x1

8.  Remove the nut and lock washer and insert the threaded  

 

end of the strain relief (provided in the installation kit)  

 

into the selected opening on the fixture. Secure the  

 

strain relief by tightening the nut and lock washer. The  

 

nut and lock washer should be tightened with a tool  

 

such as a pair of pliers to ensure the strain relief is  

 

properly grounded to the fixture.

9.  It is recommended that a pilot hole be drilled in the  

 

mounting surface for wood screws. Pre-drill holes in  

 

the mounting surface with a 1/16in. (1.5 mm) drill  

 

bit for softwoods and a 3/32in. (2.4 mm) drill bit  

 

for hardwoods.

10. Drive the screws provided in the mounting hardware into  

 

the mounting surface until approximately 1/8in.  

 

(3.1mm) of space remains under the head of the screw  

 (

see Figure 3

).

11. Align the keyholes in the fixture with the two screws and  

 

slide into place (

see Figure 4

).

12. Tighten screws to secure fixture.
13. For ease of installation, the top cover can be hung on  

 

the base, which is already attached to the cabinet, using  

 

the built-in hanging flanges.

14. Install the armored cable to meet electrical codes.  

 

Tighten the two screws on the strain relief connector to  

 

secure the cable. 

15.  Connect the hot (black) AC supply wire to the hot (black) wire  

 

of the fixture. Secure the connection with the wire nuts  

 

provided (

see Figure 5

). Pull wires to check for tightness.

16.  Connect the neutral (white) AC supply wire to the neutral  

 

(white) wire of the fixture. Secure the connection with the  

 

wire quick connects provided (

see Figure 5

). Pull wires to  

 

check for tightness.

17.  Connect the ground (green or bare copper) AC supply wire to  

 

the green or bare copper ground (green or bare copper)  

 

wire of the fixture. Secure the connection with the wire  

 

quick connects provided (

see Figure 5

). Pull wires to  

 

check for tightness. If your electrical system contains no  

 

grounding wire, you should consult a qualified electrician  

 

before proceeding with the installation.

18.  Ensure that no bare wires are exposed after making the  

 

electrical connections.

19.  Arrange the wires inside the fixture and reattach the cover/ 

 

housing by reversing the removal instructions. Ensure all  

 

the wires and connections are sealed properly inside the  

 

fixture without pinching any wires. Ensure the top cover  

 

screws and washers are secure.

20.  Reinsert lens.
21.  Turn on the electricity at the circuit breaker or fuse box.

DIMMABLE FUNCTIONALITY

1.  For use of dimming function, please use a compatible LED dimmer.
2.  Follow dimmer setup instructions for optimal performance.

SELECTING COLOR TEMPERATURE

This Honeywell LED light fixture allows you to select from a warm white 

light (2700K), cool white light (4000K) or daylight setting (5000K). To 

select your desired CCT, simply use the 3-position switch: WW (Warm 

White) CW (Cool White) or DL (Daylight). Please note that the switch 

only controls the color temperature for a single fixture. It does not control 

other connected fixtures.

FIGURE 3

1/8IN.

3.1MM

FIGURE 4

FIGURE 5

INSERT

SLIDE

FIGURE 2

1/16IN. (1.58MM)

Summary of Contents for 45366

Page 1: ...operly grounded to the fixture 9 It is recommended that a pilot hole be drilled in the mounting surface for wood screws Pre drill holes in the mounting surface with a 1 16in 1 5 mm drill bit for softwoods and a 3 32in 2 4 mm drill bit for hardwoods 10 Drive the screws provided in the mounting hardware into the mounting surface until approximately 1 8in 3 1mm of space remains under the head of the ...

Page 2: ...to date product support accessories electronic PDF format manuals and more visit www byjasco com support DO NOT RETURN THIS PRODUCT TO THE STORE STOP FCC IC EN SPECIFICATIONS The Honeywell Trademark is used under license from Honeywell International Inc Honeywell International Inc makes no representation or warranties with respect to this product This product is manufactured by Jasco Products Comp...

Page 3: ...e colocarán los tornillos para madera Previamente perfore orificios en la superficie de montaje con una broca de 1 16 pulgadas 1 5 mm para madera blanda y una broca de 3 32 pulgadas 2 4 mm para madera dura 10 Coloque los tornillos provistos con las herramientas de montaje en la superficie de montaje hasta que quede un espacio aproximado de 1 8 pulgada 3 1 mm entre la superficie y la cabeza del tor...

Page 4: ... televisión lo que puede determinarse encendiendo y apagando el equipo se recomienda que el usuario intente corregir la interferencia aplicando una o más de las siguientes medidas Reoriente o reubique la antena receptora Incrementar la separación entre el equipo y el receptor Conectar el dispositivo a un tomacorriente de un circuito diferente del circuito al que el receptor está conectado Consulte...

Reviews: