background image

 

 

N7131V5  5/04  Rev. A 

 

ADEMCO 5802MN 

SUPERVISED MINIATURE 

TRANSMITTER

 

INSTALLATION AND SETUP GUIDE 

The ADEMCO 5802MN is a wireless transmitter that may 
be worn on a belt (belt holder supplied) or around the 
neck (necklace supplied). Pressing the button on the 
transmitter sends a signal to the control receiver. The 
5802MN is intended for use only with wireless alarm 
systems that support 5800 Series devices. 

The transmitter is supervised, i.e., every hour it 
automatically sends a message to the control receiver 
that includes battery status information.  

This transmitter can be programmed as any zone type 
response (e.g., Emergency Panics, Relay Action, etc.). 

Battery Replacement 

The 5802MN is powered by a long-life Lithium battery that 
may be replaced when a low battery is eventually 
indicated by the control unit. 

NOTE: 

 Although the 5802MN is water-resistant, please 

do not submerge. 

Programming the Serial Number

 

The 5802MN has a unique identification code (serial 
number) permanently assigned during manufacture. 

You must “enroll” the transmitter’s serial number and loop 
number during system programming. The 5802MN may 
be defined as Input Type “RF” (supervised RF, for an 
hourly check-in; 

do not 

take out of range) or “UR” 

(Unsupervised RF). Its loop number is “1.” See the control 
unit’s Installation Instructions for further details regarding 
programming. 
When installation is complete, verify operation from 
desired location(s). 

 

Specifications 

 

Unit Dimensions: 

 

2.4” (61mm) x 1.5” (38mm) x 0.5” (13mm) 

 

LED:

 

Lights when unit transmits. 

 Battery:

  3V Duracell DL 2032 or Newsum, Maxell, Panasonic, 

Renata, or Sanyo CR2032 

 

 

In UL installations: 3V Newsum, Maxell, or 

 

Renata CR2032 only

 

Back of 5802MN

Remove

battery

cover

Slide 

battery

under 

pin

Battery

3V

LITHIUM

RENATA

CR2032

5820MN

 

Battery access is via a 

quarter 

turn

 (use a nickel to open 

case back). Excessive turning 
may result in damaging the 
cover. 

Note battery polarity: 
+ POS 

end must face up 

(visible when installed).

 

 

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE 
RECEIVER/CONTROL W ITH W HICH THIS DEVICE IS USED FOR 
WARRANTY INFORMATION AND FOR DETAILS REGARDING THE 
LIMITATIONS OF THE ENTIRE ALARM SYSTEM. 

 

FCC STATEMENT 

FCC ID: CFS8DL5802MN   

CANADA: 1748101382 5 3 

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions: 

(1) This device may not cause harmful interference 
(2) This device must accept any interference received, including 

interference that may cause undesired operation.

 

UL

 

US Listings: 

HOUSEHOLD BURGLARY WARNING SYSTEM 

CONTROL UNIT ACCESSORY 

UL

 

Canadian Listings: 

HOUSEHOLD BURGLARY W ARNING SYSTEM CONTROL UNIT 
ACCESSORY ALSO LISTED FOR USE AS A SIGNAL APPLIANCE, 
MISCELLANEOUS CERTIFIED FOR CANADA.

 

ÊN7131V5WŠ

N7131V5  5/04  Rev. A  

 

Reviews: