K3636CN 9/00 Rev. B
$'(0&2%'9&1
7:2:$<:,5(/(66.(<ZLWK92,&(67$786
USER GUIDE
About the 5804BDV
The 5804BDV-CN is a four-button remote control for your alarm system. It can send a command to the alarm system, such as to arm or disarm, as well
as receive system status. Two LEDs and a speaker indicate system status. The 5804BDV-CN is typically used for arming, disarming, and home
automation. Check with your installer to understand which functions the buttons have been assigned on your unit.
Operating the Buttons
Activating a Function
To activate a function, press and hold the appropriate button down until the yellow LED flashes, and then release it.
Requesting System Status
You can check system status before arming or disarming your system.
Check your system status by momentarily pressing and releasing any button. The yellow LED will flash after you release the button.
After a second or two, the 5804BDV-CN will display the system status through the LEDs and speaker (see the System Status
Indications Table, below). If the 5804BDV-CN does not receive system status from the panel for approximately 5 seconds, it will shut
itself down. It will also shut itself down if you do not press a button within 5 seconds of receiving a status update.
System Status Indications Table
LED
LED Condition
Speech
System Status
System Armed Away
Armed Away or Maximum
On Steady
System Armed Stay
Armed Stay or Instant
Fire, Fire Zone (Faulted Zone)
Fire Alarm in progress
Alarm, Alarm Zone (Faulted Zone)
Armed, Burglary Alarm in progress
Red
Flashing
Alarm, Alarm Zone (Faulted Zone)
Alarm Memory
Green
On Steady
System Disarmed Ready To Arm
Disarmed, Ready to Arm
Yellow (right)
Flashing
—
Indicates RF transmission
In Enter House ID Mode
Red & Green
Alternately Flashing
—
In Set Volume Level Mode
AC Loss
AC Loss Condition
Low Battery
Low Battery Condition
Green
Flashing
System Disarmed Not Ready To Arm
System Not Ready, Zones Faulted
Multiple Button Operations
WARNING!
The 5804BDV-CN should not be used for silent
panic operation.
The 5804BDV-CN can generate the same responses as
keypad panic key pairs of [
✶
] + [#] and [
✶
] + [1] by depressing
“A” + “C” and “B” + “D” button pairs, respectively. You must
depress the button pair for at least 2 seconds for the
5804BDV-CN to recognize the button pair command. These
button pairs allow you to activate panic, fire, and medical
alarms depending on control panel programming.
5804BDV-005-V0
A + C Button Pair
B + D Button Pair
Adjusting the Volume Level
To enter the Volume Level mode, press and hold down the A, B, and D buttons at the same time until the unit’s red and green LEDs
flash alternately. If no button is pressed within 5 seconds, the unit will automatically shut down and no change to the volume level is
made. You press the A button for
low
volume level, the B button for mid volume level, and the C button for maximum volume level. You
will hear a tone for the selected volume. You then press the D button to accept the sound level you have selected. Note that volume
level affects the life of the battery. Use low volume for maximum battery life.