background image

 

Installation and Service Instructions for CX Weather-Sealed 

ISSUE 4

Explosion-proof Switches

 

PK 88136

 

 

       0518

 

 

 

Sensing and Control 

 

 

WARNING 

IF USED IN APPLICATIONS CONCERNING HUMAN 
SAFETY 

 

Only use NC direct opening (“positive 
opening”/”positive break”) contacts, identified by the 
symbol  .  

 

Do NOT use flexible/adjustable actuators. Only use 
actuators designed for safety applications. 

 

Do NOT defeat, tamper, remove, or bypass this 
switch. 

 

Hazardous voltage, disconnect power before 
servicing. 

 

Strictly adhere to all installation and maintenance 
instructions. 

 

Consult with local safety agencies and their 
requirements when designing a machine-control 
link, interface and all control elements that affect 
safety. 

Failure to comply with these instructions could 
result in death or serious injury. 

 
GENERAL INFORMATION 

Sealed construction for Honeywell CX explosion-

proof switches provides protection from the entry of 
water, dust and oil as defined in NEMA 3, 4, 4X, 6, 
6P, 13, and IP66/IP67 as defined in IEC 529. 

CX Series products with conduit types ¾-14NPT 

also meet the North American Hazardous Locations 
Designation: Class I, Group C and D; Class II, 
Groups E, F and G. CX listings beginning with 
numbers 14, 16, 24, 26, 36, or 84 (example: 14CX1) 
also meet Class I, Group B. These explosion-proof 
and weather-sealed switches are protected from 
flammable hydrocarbon atmospheres, metal dust, 
coal dust, and grain dust, and comply with UL 
Standard: UL 894 and UL 1203, CSA Standard: 
C22.2 no. 25-1966, C22.2 no. 30-M1986. 

Select CX Series products also meet the European 

Hazardous Locations Designation: EExd IIC T6 
category II 2 GD, KEMA 01ATEX2111X and 
complies with the European Directive on Equipment 
and Protective Systems Intended for Use in 
Potentially Explosive Atmospheres (94/9/EC) 
commonly referred to as the ATEX Directive. 

Compliance with the Essential Health and Safety 
Requirements has been assured by compliance with 
EN50014 1997, EN50018 1994 and EN50281-1-1. 
The European-approved products have a 
temperature range of –40 °C to 70 °C [–40 °F to 
158 °F], and when used within the maximum voltage 
and current specified on the product will have no 
heating problems. 

Notice: 

As ambient temperature 

approaches 60 °C [140 °F], the cable entry can be 
70 °C [158 °F] or higher. Cable branching can be 
80 °C [176 °F] or higher, making it important to select 
cable that meets these requirements. 

Application Note: 

Enclosures are based, in 

general, on the broad definitions outlined in NEMA 
standards. Therefore, it will be necessary for the user 
to determine that a particular enclosure is adequate 
when exposed to the specific conditions that might 
exist in intended applications. Except as might 
otherwise be noted, all references to products 
relative to NEMA enclosure types are based on 
MICRO SWITCH evaluation only. 

IMPORTANT: 

Switches without shaft re-storing 

force do not have overtravel stops. On switches with 
potentiometers, use care to insure that overtravel 
does not exceed 125° in the application and during 
set-up. 
 

LEVER POSITIONING 

Loosen the screw with a 9/64 inch hexagon key 

wrench, move the lever to the desired position and 
securely tighten the screw until the "teller tab" can no 
longer be moved by hand. Then tighten the screw 
another 1/8 to 1/4 turn to assure that the lever is tight 
on the shaft. Hexagon key wrenches are provided in 
adjusting tool set LSZ4005 for this purpose. 

CAM ADJUSTMENT 

Pretravel, overtravel, and actuation sequencing 

can be adjusted and/or modified in the field. No tools 
are required. 

To Adjust Plunger Types: 

1.  Lift cam follower. 
 

 

Summary of Contents for CX Series

Page 1: ...uipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres 94 9 EC commonly referred to as the ATEX Directive Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN50014 1997 EN50018 1994 and EN50281 1 1 The European approved products have a temperature range of 40 C to 70 C 40 F to 158 F and when used within the maximum voltag...

Page 2: ...s obtained Operation is in the direction of the inclined surface of the symbol when or lines up with the pointer on the cam follower 4 When cam wheel has been rotated to desired location release cam wheel to engage with mating shaft disc 5 Release cam follower CX Wiring Methods Honeywell recommends that conduit be installed per NEC articles 501 4 and 501 5 REPLACEMENT PARTS Replacement switch asse...

Page 3: ...CX 282CX 92CX 14CX 24CX 64CX 74CX 84CX 284CX 94CX 16CX 26CX 66CX 76CX 86CX 286CX 96CX 1172CX 2172CX 9172CX Pretravel max 15 15 30 30 15 Differential Travel max 5 10 25 20 5 Overtravel min 90 90 75 75 90 Circuitry Single Pole Double Throw Single Pole Double Throw Double Pole Double Throw Single Pole Double Throw Gold Contact Single Pole Double Throw Electrical Ratings UL CSA Rating L96 15 A 120 240...

Page 4: ...itial position Next rotate shaft a half 180 turn CW and then a half turn CCW back to initial position Use Step 2 if the function switch is set in the CCW position 2 Rotate operating shaft a quarter turn 90 CW and then a quarter turn CCW back to the initial position Next rotate shaft a half turn 180 CCW and then a half turn CW back to initial position Procedure 3 1 Wiring See figure 3 Connect a 12 ...

Page 5: ...4 37 MAX 104 4 09 MAX 96 3 78 Ø 98 3 86 TYP 12 7 50 20 3 80 25 4 1 00 Ø 97 3 82 20 3 80 25 4 1 00 22 3 88 9 4 37 MAX 145 5 71 MAX 133 5 24 MAX 145 5 71 MAX 133 5 24 5 1 20 19 4 76 20 3 80 25 4 1 00 Ø 98 3 86 TYP 12 7 50 20 3 80 25 4 1 00 MAX 96 3 78 MAX 104 4 09 5 1 20 19 4 76 TYP 60 3 2 38 40 1 57 18 3 72 80 3 15 101 6 4 00 50 8 2 00 4X F THRU 8 5 33 F MAX 31 4 1 23 Ø 97 3 82 70 29 1 THESEHOLESNO...

Page 6: ...warranty information If warranted goods are returned to Honeywell during the period of coverage Honeywell will repair or replace without charge those items it finds defective The foregoing is Buyer s sole remedy and is in lieu of all other warranties expressed or implied including those of merchantability and fitness for a particular purpose Specifications may change without notice The information...

Reviews: