background image

DF-RC

Honeywell

Manual

RF Remote Control Decorative Fire

Summary of Contents for DF-RC

Page 1: ...DF RC Honeywell Manual RF Remote Control Decorative Fire ...

Page 2: ... Key Up Key Down Key Stop Stand by Key Menu Display DISPLAY AND KEYS ...

Page 3: ...instance while decorative fire is been ignited Fault Main plug of the decorative fire is plugged in the other way round RF communication Batteries are almost empty symbol flashes Time representation 24 hours or 12 hours Days of the week Square indicates actual day Temperature representation Temperature sensor s are defect Keys Enhance setting or change selection Lower setting or change selection C...

Page 4: ...four or six different time periods can be set The time schedule can easily be set by setting the begin time and the temperature set point of each period Flame Symbol A flame symbol indicates that the burner of your decorative fire has been switched on Batteries Before you can take the RF remote control in operation the two supplied batteries type AA have to be placed After the batteries have been ...

Page 5: ...s follows Press keys and simultaneously The display below is shown This display is shown during binding The symbol flashes When the binding is finished the default display is shown Note In case of replacement of the decorative fire or the RF remote control the binding has to be initiated manual see Binding RF remote control on page17 Time and Day The time schedule of the RF remote control can only...

Page 6: ...Installation menu Press key once to select the User menu or keep key pressed for ten seconds to select the Installation menu Manual Operation Dependent on the choice made in the User menu the temperature or the flame height can be controlled manual Flame height control The decorative fire must be manually switched on and off Igniting decorative fire Press keys and simultaneously if the adjacent di...

Page 7: ...Setting flame height Press key or once The display below is shown The value of the current flame height flashes Set the required flame height by pressing key or Dependent on the key pressed the symbol or is shortly visible on the display The flame height can be set between1 and 15 Wait a few seconds or press key to leave the menu Note The flame height can only be controlled if the decorative fire ...

Page 8: ...n again Temperature control The decorative fire is automatically switched on and off according to the heat demand Press key or once to adjust the required temperature The display below is shown The current temperature set point flashes Set the required set point by pressing key or Dependent on the key pressed the symbol or is shortly shown on the display The temperature can be set between 7 0 and ...

Page 9: ...icate the decorative fire is being switched off After the decorative fire has been switched off the display below is shown The symbol flashes to indicate the decorative fire has to be ignited manually by pressing the keys and simultaneously When the decorative fire is ignited again the temperature control becomes active Note The temperature set point can not be changed during the temporarily tempe...

Page 10: ...ow is shown The current temperature set point flashes Set the temporarily required temperature set point by pressing key or Dependent on the key pressed the symbol or is shortly shown on the display Wait a few seconds or press key to leave the menu This display example is shown The symbol indicates that the temperature set point has been adjusted manually The temporarily adjustment can be undone b...

Page 11: ... to indicate the decorative fire is being switched off After the decorative fire has been switched off the display below is shown This display example is shown Symbol flashes to indicate the decorative fire has to be ignited manually by pressing keys and simultaneously When the decorative fire is ignited the time schedule becomes active again Note The temperature set point can not be changed when ...

Page 12: ...sing key or five seconds after the last key press Manually or Time Schedule Press key once The display below is shown A combination of two symbols flashes There are three possilbe combinations manually with flame height control manually with temperature control time schedule temperature control Select the required combination by pressing key or Wait a few seconds or press key to leave the menu The...

Page 13: ...the actual time by pressing keys and Press key The days of the week are flashing Select the actual day of the week by pressing keys and The open square indicates the day selected Wait a few seconds or press key to leave the menu Note The days of the week are not shown in case a 1 day time schedule has been chosen ...

Page 14: ...Press key a few times until the diplay below is shown The begin time of time period I flashes Set the required begin time by pressing keys and Press key The current temperature set point of time period I flashes Set the required temperature set point for time period I by pressing keys and Press key and repeat the steps above to set the required begin time and temperature set point for all periods ...

Page 15: ...periods per day II IV or VI Note The Installation Menu can be closed by pressing key or automatically five seconds after the last key press 12 or 24 Hours Representation Press key a few times until one of the displays below is shown The current set time representation flashes Select the required time representation by pressing key or Wait a few seconds or press key to leave the menu The availibili...

Page 16: ...owing 1 6 Wait a few seconds or press key to leave the menu Note Choice means no time schedule is used Only manually operation with flame height control is now possible Day Time Periods II IV or VI Press key a few times until one of the displays below is shown The current choice digits flashes Select the required day time periods II IV of VI by pressing key or Wait a few seconds or press key to le...

Page 17: ...ct as follows Press key a few times until the display below is shown Make sure the decorative fire has not been switched on for more than 5 minutes Press keys and simultaneously The binding is started and the display below is shown This display is shown during the binding The symbol flashes When the binding succeeds the default display is shown ...

Page 18: ...cover down a few millimeters see figure 1 and then lift up the back cover Remove the old batteries from its holder Place a new set of batteries in the holder as shown in figure 2 Replace the back cover of the RF remote control by placing the tabs A and B of the back cover figure 3 in the according notches of the housing figure 2 Push the back cover up to secure it The current time and day of the w...

Page 19: ...19 figure 1 figure 2 figure 3 A A A A B B B B ...

Page 20: ... control is probably too large Hold the RF remote control nearer to the decorative fire Fault of the decorative fire The display shows an F followed by a 2 digit fault code The symbol flashes A so called lock out fault of the decorative fire On the display an F followed by a 2 digit fault code is shown The text reset indicates that the decorative fire can be reset The symbol flashes See also Termi...

Page 21: ...atter not present There is an automatic switchover to manual operation with flame height control Terminating a Lock Out Failure A lock out failure the text reset is shown of the decorative fire could possibly be terminated Press keys and simultaneously The display below is shown The symbol indicates that it is possible to reset the decorative fire After the decorative fire has been reset the defau...

Page 22: ...months from the date of purchase This date must be included on a valid proof of purchase This warranty covers manufactoring faults with respect to material components or finishing Defects or malfunctions caused by wrong application or treatment of this product are excluded from this warranty Claims to this warranty must always be made at the retailer of this product ...

Page 23: ...ion 6 Time Schedule 10 USER MENU 12 Manually or Time Schedule 12 Setting Time and Day 13 Setting Time Schedule 14 INSTALLATION MENU 15 12 or 24 Hours Representation 15 Time Schedule 1 5 2 7 days or 16 Day Time Periods II IV or VI 16 Binding RF Remote Control 17 REPLACING BATTERIES 18 FAULT INDICATION 20 Terminating a Lock Out Failure 21 WARRANTY 22 ...

Page 24: ...Honeywell EN2H 0035NL15 R0806 ...