background image

Honeywell

H46C,E  Humidity Controllers

INSTALLATION  INSTRUCTIONS

APPLICATION

The  H46C,E  Humidity Controllers are used with portable 

and central  unit dehumidifiers to  maintain  relative 

humidity. The  H46  has an spst,  snap-acting  switch 

designed for line voltage circuits.  The  H46C has two 

leadwires for switch  box mounting.  The  H46E  has an 

electric cord with an interrupter plug.

INSTALLATION

When  Installing  this  Product...

1.

  Read these  instructions carefully.  Failure to follow 

them could damage the product or cause a hazard­

ous condition.

2.

  Check the ratings given in the instructions and on 

the product to  make sure the  product is suitable for 
your application.

3.

  Installer must be a trained,  experienced service 

technician.

4.

  After installation  is complete,  check out  product 

operation as  provided  in these instructions.

A  CAUTION

Electrical Shock Hazard.

Can cause electrical  shock or equipment

 

damage.

Disconnect power supply  before connecting 
wiring.

Location

Select a  location about 5 ft (1.5 m)  above the floor in an 
area with  good circulation at average temperature and 

humidity for the area to be controlled.  Avoid locations 
near hot or cold air ducts and discharge  air from the 

controlled equipment.

Mounting  H46C

1.

  Remove the  setting  knob.

2.

  Pull the cover forward from the  device to  remove.

3.

  Install a 2 in.  x 3  in.  (51  mm x 76 mm) vertical 

switch  box at the selected  location.

4.

  Using the two screws provided,  fasten the adapter 

plate to the switch box as shown.  See Fig.  1.

5.

  Pull the wires from the switch  box through the 

opening  in the  adapter plate and connect to the 

H46  leadwires with the  solderless connectors 
(provided).  See  Fig.  4-6 for typical  hookups.

6.

  Push the wires back into the switch box.

7.

  Place the  H46 against the adapter plate,  making 

certain the tab at the bottom of the plate fits into the 

notch on the  H46.

8.

  Fasten the  H46 to the adapter  plate by tightening 

the captive screw.

9.

  Replace the cover and the setting  knob.

Mounting  H46E

1.

  At the  selected  location,  insert the two wood 

screws (provided)  into the wall  2 in.  (51  mm) 

vertically apart and protruding  1/16 in.  (2 mm) from 
the wall.  See  Fig.  2.

2.

  Position the  H46 on the screws and slide  it down 

until the screws are in the  slots.

3.

  Insert the dehumidifier plug into the  end of the 

interrupter plug.  See  Fig.  3.

4.

  Insert the  interrupter plug into the electrical  outlet.

NOTE:  H46E  has a 3-prong  plug.  When connecting to 

the 2-prong receptacle,  use the converter plug 

(not included) and connect the pigtail lead to the 
ground screw.

®   U . S .   R e g i s t e r e d   T r a d e m a r k

C o p y r i g h t  ©   2 0 0 3   H o n e y w e l l   I n t e r n a t i o n a l   In c .

• All Rights Reserved

6 9 -1 0 0 0 B -1

Summary of Contents for H46E

Page 1: ...6C 1 Remove the setting knob 2 Pull the cover forward from the device to remove 3 Install a 2 in x 3 in 51 mm x 76 mm vertical switch box at the selected location 4 Using the two screws provided fasten the adapter plate to the switch box as shown See Fig 1 5 Pull the wires from the switch box through the opening in the adapter plate and connect to the H46 leadwires with the solderless connectors p...

Page 2: ...at can be wired in parallel or in series Wiring in parallel allows the dehumidistat to indepen dently control the humidity level but could cause overcooling of the home During unoccupied times the homeowner should set the thermostat to a relatively high setting and control moisture using the dehumidistat Wiring in series prevents overcooling but the air conditioner runs only when both the thermost...

Page 3: ...IDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED HEATING DAMPER MOTOR IF USED CLOGGED FILTER SWITCH OR COOLING PANEL CONNECTION COOLING CONTACTOR COIL FAN RELAY COIL A M7913 Fig 5 Typical parallel wiring hookup for H46C with T87F Q539A combination for dehumidification and mildew control 3 69 1000B 1 ...

Page 4: ...e knob counterclockwise to the stop to place the H46 in the Off position CHECKOUT After all mounting and wiring is completed turn on the power supply Place the system into operation by turning the setting knob toward the low end of the scale until the dehumidifier motor starts Turn the setting knob slowly toward the high end of the scale until the dehumidifier motor stops Honeywell Automation and ...

Page 5: ... sortie d air de l appareil de régulation Montage du H46C 1 Enlever le bouton de réglage 2 Tirer le couvercle vers l avant pour l enlever 3 Installer une boîte de commutation verticale de 51 x 76 mm 2 x 3 po à l endroit choisi 4 À l aide des deux vis fournies fixer la plaque d adaptation à la boîte de commutation Voir Fig 1 5 Passer les fils de la boîte de commutation dans l ouverture de la plaque...

Page 6: ...arallèle permet de faire fonctionner le déshumidistat de façon autonome pour qu il règle le taux d humidité sans provoquer le refroidissement exagéré de la maison Pendant les périodes d inoccupation le propriétaire devrait régler le thermostat à un réglage relativement élevé et maîtriser l humidité en se servant du déshumidistat Le raccordement en série empêche le refroidissement exagéré mais le s...

Page 7: ...C HYGROSTATS H46C E H46C SCHÉMA INTERNE DE Q539A T87F Fig 5 Schéma de câblage parallèle type du H46C et du T87F Q539A pour assurer la déshumidification et empêcher le développement de moisissure 3 1000B 1 ...

Page 8: ...ntihoraire jusqu au point d arrêt pour mettre le H46 à la position Off VERIFICATION Une fois le montage et le raccordement terminés mettre l hygrostat sous tension Tourner lentement le bouton de réglage vers l extrémité inférieure de l échelle jusqu à ce que le moteur du déshumidificateur se mette en marche Tourner lentement le bouton de réglage vers l extrémité supérieure de l échelle jusqu à ce ...

Reviews: