APPLICATION

This kit contains your new Honeywell HE105 or HE205 
Humidifier, H8908 Humidistat and all the accessories 
required for installation. 

How Your Humidifier Works

Your Honeywell humidifier uses the principle that vapor 
(evaporated water) is created when warm air blows over a 
water-soaked area. As the vapor circulates, the relative 
humidity rises.

Your humidity control monitors the relative humidity and 
activates the humidifier accordingly. The humidifier has a 
water supply that dispenses water evenly over a humidifier 
pad. The warm dry air from the furnace passes over the 
humidifier pad and picks up the moist air to circulate it 
throughout your home.

Humidified air feels warmer and more comfortable so you 
may be able to lower your thermostat heating setpoint, 
which saves money on your heating fuel bills. The end 
result is that your humidifier gives you a comfortable 
environment that is also energy efficient.

Need Help?

For assistance with this product please visit 
http://yourhome.honeywell.com or call Honeywell 
Customer Care toll-free at 1-800-468-1502. 

PREPARING FOR THE 
INSTALLATION

Be sure to identify all the required (Table 1) accessories 
(included) and make sure the appropriate tools are 
available before beginning the installation.

Included in the box:

• Humidifier
• H8908 Humidistat
• Plug-in transformer

Canadian “C” models also include:

• 6 in. dia. bypass ducting (24 in.)
• 18 gauge thermostat wire (20 ft.)
• 1/4 in. (6.35 mm) OD feed water tubing (20 ft.)
• 1/2 in. (12.7 mm) ID drain tubing (10 ft.)
• Saddle valve

Required Tools

Tools required for installation include:
• Tin  snip
• Screwdriver
• Pliers
• Adjustable or open-end wrench
• Drill
• Level
• 3/4 in. (19 mm) sheet metal drill bit

SPECIFICATIONS

Model specific specifications are shown in Table 1.

Operating Ambient Temperature: 

41 to 113 °F (5 to 45 °C)

Power Supply: 

24 VAC / 60 Hz.

Power Consumption: 

7 Watts with 24 Vrms

Water Pressure: 

40 to 120 psi.

Orifice Output: 

.02 in. (0.5 mm)

Flow Rate at Nozzle: 

4.7 GPH (18 L/hr.) under 120 psi

Table 1. Specifications.

Model

Size

length × width × depth

Duct Opening

H × W

Pad Size

Evaporation 

Output

HE105

15.16 × 16.57 × 9.47 in.

(385 × 421 × 240 mm)

9.43 × 9.28 in.

(240 × 236 mm)

10 × 9.5 × 1.5 in.

(254 × 241 × 38.1 mm)

12 GPD

HE205

18.30 × 17.11 × 9.59 in.

(465 × 434 × 243 mm)

12.63 × 9.68 in.

(321 × 246 mm)

13.125 × 10 × 1.5 in.

(333 × 254 × 38.1 mm)

17 GPD

Summary of Contents for HE105

Page 1: ...me honeywell com or call Honeywell Customer Care toll free at 1 800 468 1502 PREPARING FOR THE INSTALLATION Be sure to identify all the required Table 1 accessories included and make sure the appropriate tools are available before beginning the installation Included in the box Humidifier H8908 Humidistat Plug in transformer Canadian C models also include 6 in dia bypass ducting 24 in 18 gauge ther...

Page 2: ... cause property or equipment damage Locate humidifier where ambient temperature is between 41 and 113 F 5 to 45 C Do not install humidifier where freezing temperatures could occur Be sure supply plenum static pressure is no greater than 0 4 in wc and water pressure is no greater than 120 psi CAUTION Sharp Edges Installation Hazard Can cause personal injury Wear gloves and safety glasses IMPORTANT ...

Page 3: ...RTANT Be sure the mounting template is level before marking Use of a small level is recommended 3 Locate the template form number 33 00210 included in the box For the HE105 model cut out the template along the dotted line For the HE205 model use the entire sheet as a template 4 Tape the template in position and trace around the template 5 Remove the template and carefully cut the rectangular openi...

Page 4: ...f the cover Fig 6 Connecting bypass ducting Connecting the Plumbing 1 Hot or cold water either hard or softened can be used in the humidifier Cut the water line so it reaches from the humidifier to the main water supply tap 2 Turn off water supply and tap into a water line Consult local codes for proper plumbing Use an approved saddle valve or a T fitting and manual shutoff valve to tap into the w...

Page 5: ...ng steps to check the humidifier operation 1 Turn on the power and the water supply 2 Ensure the saddle valve or T valve fitting is fully opened by turning the handle to the left counter clockwise until there is resistance 3 Turn the H8908 Humidistat to On and turn on the heat by setting the thermostat to 10 ºF 6 ºC above room temperature 4 Make sure that water is flowing out of the drain hose If ...

Page 6: ...use either hard or soft water in your humidifier but hard water mineral deposits are more difficult to clean than soft water deposits IMPORTANT Never oil any part of the humidifier End of Humidification Season Clean the humidifier and shut it off at the end of the heating season Turn the water off at the saddle valve or T valve fitting by turning the handle to the right clockwise until the water s...

Page 7: ...ier Remove cover and verify that water flows into distribution tray Drain tubing Verify no obstructions Air leakage Check duct joints Seal with foil tape Low humidity Furnace blower not operating Reset circuit breaker or check for blown fuse Check that the furnace power is on Check all external wiring connections Check the humidity control setting Call a professional heating contractor Rapid air c...

Page 8: ... is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM...

Page 9: ...e de Honeywell au 1 800 468 1502 PRÉPARATION À L INSTALLATION Veiller à identifier tous les accessoires inclus répertoriés dans le tableau 1 et s assurer que les outils appropriés sont disponibles avant de commencer l installation Inclus dans la boîte Humidificateur Humidistat H8908 Transformateur enfichable Les modèles C canadiens incluent également Conduit de dérivation de 6 po de dia 24 po Fil ...

Page 10: ...a température ambiante est comprise entre 5 C et 45 C 41 F et 113 F Ne pas installer l humidificateur dans un endroit où des températures inférieures ou égales à 0 C 32 F peuvent être présentes S assurer que la pression statique de l alimentation dans le plénum ne dépasse pas 0 4 po c e et que la pression de l eau ne dépasse pas 120 psi MISE EN GARDE Danger de bords coupants durant l installation ...

Page 11: ...Il est recommandé d utiliser un niveau de petite taille 3 Repérer le gabarit formulaire n 33 00210 inclus dans la boîte Pour le modèle HE105 couper le gabarit le long de la ligne pointillée Pour le modèle HE205 utiliser la feuille entière comme gabarit 4 Fixer le gabarit à l emplacement requis avec du ruban adhésif et en tracer le contour 5 Enlever le gabarit et couper avec soin une ouverture rect...

Page 12: ...couvercle et le fixer avec la vis de serrage à main située en bas du couvercle Fig 6 Connexion du conduit de dérivation Connexion de la plomberie 1 L humidificateur fonctionne avec de l eau dure ou de l eau douce L eau peut être chaude ou froide Couper la canalisation d eau de façon à ce qu elle s achemine de l humidificateur à la prise d arrivée d eau principale 2 Fermer l arrivée d eau et accéde...

Page 13: ...eau à l intérieur de l humidificateur est connectée au plateau de distribution d eau PerfectFLO Après l installation procéder aux étapes suivantes pour vérifier le fonctionnement de l humidificateur 1 Mettre sous tension et ouvrir l arrivée d eau 2 S assurer que la vanne à étrier ou le raccord de vanne en T est complètement ouvert e avec la poi gnée tournée à gauche sens antihoraire jusqu à sentir...

Page 14: ...es dépôts minéraux de l eau dure sont plus difficiles à nettoyer que les dépôts d eau douce IMPORTANT Ne jamais huiler une pièce quelle qu elle soit de l humidificateur Fin de la saison d humidification Nettoyer l humidificateur et l éteindre à la fin de la session de chauffage Couper l eau au niveau de la vanne à étrier ou du raccord de vanne en T en tournant la poignée à droite sens horaire jusq...

Page 15: ...ifier que l eau s écoule dans le plateau de distribution Tube d évacuation Vérifier qu il n y a pas d obstruction Fuite d air Vérifier les joints des conduits Sceller avec du ruban en aluminium Basse humidité La soufflante de l appareil de chauffage ne fonctionne pas Réenclencher le disjoncteur ou rechercher un fusible grillé Vérifier que l appareil de chauffage est alimenté en courant Vérifier to...

Page 16: ...eur l avait en sa possession La responsabilité exclusive de Honeywell se limite à réparer ou à remplacer le produit conformément aux modalités susmentionnées HONEYWELL N EST EN AUCUN CAS RESPONSABLE DES PERTES OU DOMMAGES Y COMPRIS LES DOMMAGES INDIRECTS OU ACCESSOIRES DÉCOULANT DIRECTEMENT OU INDIRECTEMENT D UNE VIOLATION QUELCONQUE D UNE GARANTIE EXPRESSE OU TACITE APPLICABLE AU PRÉSENT PRODUIT ...

Reviews: