INSTALLATION INSTRUCTIONS
33-00229EF-01
HE105, HE205
Whole Home Bypass Humidifier
APPLICATION
This kit contains your new Honeywell HE105 or HE205
Humidifier, H8908 Humidistat and all the accessories
required for installation.
How Your Humidifier Works
Your Honeywell humidifier uses the principle that vapor
(evaporated water) is created when warm air blows over a
water-soaked area. As the vapor circulates, the relative
humidity rises.
Your humidity control monitors the relative humidity and
activates the humidifier accordingly. The humidifier has a
water supply that dispenses water evenly over a humidifier
pad. The warm dry air from the furnace passes over the
humidifier pad and picks up the moist air to circulate it
throughout your home.
Humidified air feels warmer and more comfortable so you
may be able to lower your thermostat heating setpoint,
which saves money on your heating fuel bills. The end
result is that your humidifier gives you a comfortable
environment that is also energy efficient.
Need Help?
For assistance with this product please visit
http://yourhome.honeywell.com or call Honeywell
Customer Care toll-free at 1-800-468-1502.
PREPARING FOR THE
INSTALLATION
Be sure to identify all the required (Table 1) accessories
(included) and make sure the appropriate tools are
available before beginning the installation.
Included in the box:
• Humidifier
• H8908 Humidistat
• Plug-in transformer
Canadian “C” models also include:
• 6 in. dia. bypass ducting (24 in.)
• 18 gauge thermostat wire (20 ft.)
• 1/4 in. (6.35 mm) OD feed water tubing (20 ft.)
• 1/2 in. (12.7 mm) ID drain tubing (10 ft.)
• Saddle valve
Required Tools
Tools required for installation include:
• Tin snip
• Screwdriver
• Pliers
• Adjustable or open-end wrench
• Drill
• Level
• 3/4 in. (19 mm) sheet metal drill bit
SPECIFICATIONS
Model specific specifications are shown in Table 1.
Operating Ambient Temperature:
41 to 113 °F (5 to 45 °C)
Power Supply:
24 VAC / 60 Hz.
Power Consumption:
7 Watts with 24 Vrms
Water Pressure:
40 to 120 psi.
Orifice Output:
.02 in. (0.5 mm)
Flow Rate at Nozzle:
4.7 GPH (18 L/hr.) under 120 psi
Table 1. Specifications.
Model
Size
length × width × depth
Duct Opening
H × W
Pad Size
Evaporation
Output
HE105
15.16 × 16.57 × 9.47 in.
(385 × 421 × 240 mm)
9.43 × 9.28 in.
(240 × 236 mm)
10 × 9.5 × 1.5 in.
(254 × 241 × 38.1 mm)
12 GPD
HE205
18.30 × 17.11 × 9.59 in.
(465 × 434 × 243 mm)
12.63 × 9.68 in.
(321 × 246 mm)
13.125 × 10 × 1.5 in.
(333 × 254 × 38.1 mm)
17 GPD