HPL624
Power Supply/Battery Charger
PN 52263:C 1/10/08 ECN 08-029
Honeywell
12 Clintonville Road
Northford, CT 06472-1610
http://www.honeywellpower.com
Product Installation Document
1 Introduction
The
HPL624
power supply/battery charger converts a low voltage AC input into an output of 6 VDC or 12 VDC @ 1.2
amps of continuous supply current or 24 VDC @ 750 mA of continuous supply current. This general purpose linear
power supply can provide additional power for a variety of applications such as access control, security and CCTV system
accessories.
2 Specifications
•
Switch selectable for 6 VDC, 12 VDC or 24 VDC output.
•
1.2 amps of continuous supply current at 6 VDC or 12 VDC.*
•
750 mA of continuous supply current at 24 VDC.*
•
Output that is filtered and electronically regulated.
•
Built-in charger for sealed lead acid or gel type batteries.
•
Maximum charge current of 500 mA.
If a battery charger is used, subtract max charge current of
500 mA from total to determine allowable load.
•
Automatic switchover to stand-by battery upon AC fail.
•
PTC battery protection.
•
Thermal and short circuit protection with auto reset.
•
LED indicators for AC input and DC output.
•
Compact design (board dimension 3"L x 2.5"W x 1.5"H).
•
Battery leads and foam mounting tape included.
*Specified at 25ºC ambient.
3 Voltage Output and Transformer Selection
Output Voltage/Current
Switch
Transformer Requirements
SW1
SW2
12 VDC @ 1.2 amps continuous supply current
Closed
Closed
16.5VAC / 40 VA
(model HTP1640)
24 VDC @ 750 mA continuous supply current
Open
Closed
24VAC / 40 VA
(model HTP2440)
6 VDC @ 1.2 amps continuous supply current
Closed
Open
12VAC / 20 VA
(model HTP1220)
DC +
DC –
BAT +
AC
AC
HP
L6
24
.w
mf
TB1
DC LED
AC LED