background image

This system has been tested 
and certified by WQA against 
NSF/ANSI 42 for Bacteriostasis

US AP 2016/09/19

© 2016 Mitrana Group HK Ltd. All rights reserved. 

IM02-HWBAP1073-W/S/B-2016-06. 

The Honeywell Trademark is used under license from 

Honeywell International Inc. 

Honeywell International Inc. makes no representations 

or warranties with respect to this product.

This product is manufactured by Mitrana Group HK Ltd.  

For general inquires about Mitrana Group HK Ltd.

or Honeywell Water Coolers please contact 

the toll free number: 

1-855-HWHELP1 (1-855-494-3571). 

International rates may apply. 

Or visit: www.honeywellwatercoolers.com

 

 

 

 

:r

o

t

u

b

ir

t

s

i

D

 

S

U

SCA Imports LLC 

848 Brickell Ave

Suite 302

Miami, Fl 33131

 

Mitrana Group HK Ltd.

Suite B, 10/F., Hong Kong Diamond 

Exchange Building, Nos 8-10 Duddell

Street, Central, Hong Kong. 

Customer Service:

 

1-855-687-2223

 

Model / Modelo HWBAP1073 Series

Summary of Contents for HWBAP1073 Series

Page 1: ...ct to this product This product is manufactured by Mitrana Group HK Ltd For general inquires about Mitrana Group HK Ltd or Honeywell Water Coolers please contact the toll free number 1 855 HWHELP1 1 855 494 3571 International rates may apply Or visit www honeywellwatercoolers com r o t u b i r t s i D S U SCA Imports LLC 848 Brickell Ave Suite 302 Miami Fl 33131 Mitrana Group HK Ltd Suite B 10 F H...

Page 2: ...Performance Data Sheet US AP 2016 09 19 HWBAP1073 ...

Page 3: ...Hot Water Funnel Antibacterial Disc 16 US AP 2016 09 19 ...

Page 4: ...US AP 2016 09 19 ...

Page 5: ...US AP 2016 09 19 60 the tank and the Antibacterial disc is adhered to the top surface of the Hot Water Funnel Fig 1 ...

Page 6: ...US AP 2016 09 19 ...

Page 7: ...US AP 2016 09 19 ...

Page 8: ...nt Challenge Concentration of 1 0 x 10 CFU ML 1 5 x 10 CFU ML actual levels remained the same within a variation from 9 57 to 2 82 Influent Challenge Native bacteria in water 20 Challenge requirement 5 3 This system has been tested according to NSF ANSI 42 for bacteriostasis The concentration of the indicated substances in water entering the system was unchanged under the permissible limits for wa...

Page 9: ...US AP 2016 09 19 14 14 ...

Page 10: ... or warranties with respect to this product This product is manufactured by Mitrana Group HK Ltd For general inquires about Mitrana Group HK Ltd or Honeywell Water Coolers please contact the toll free number 1 855 HWHELP1 1 855 494 3571 International rates may apply Or visit www honeywellwatercoolers com r o t u b i r t s i D S U SCA Imports LLC 848 Brickell Ave Suite 302 Miami Fl 33131 Mitrana Gr...

Page 11: ...US AP 2016 09 19 HWBAP1073 Ficha Técnica de Rendimiento ...

Page 12: ...US AP 2016 09 19 Disco Antibacterial ...

Page 13: ...US AP 2016 09 19 ...

Page 14: ...US AP 2016 09 19 60 la punta metálica del tanque y el Disco Antibacterial esté adherido a la superficie superior del Embudo de Agua Caliente Fig 1 ...

Page 15: ...US AP 2016 09 19 ...

Page 16: ...US AP 2016 09 19 ...

Page 17: ...ormas NSF ANSI 42 12 FICHA TÉCNICA DE RENDIMIENTO No use el aparato con agua que no sea segura o de dudosa calidad sin la desinfección adecuada antes o después del sistema En visa de que las pruebas fueron efectuadas bajo condiciones de laboratorio el rendimiento real puede variar Concentración Máxima de 1 0 x 10 CFU ML 1 5 x 10 CFU ML los valores reales permanecieron igual dentro de una variación...

Page 18: ...US AP 2016 09 19 ...