Honeywell
Honeywell IdentIPoint
Intelligent Smartcard Readers
QUICK INSTALLATION GUIDE
95-7771
1
WARNING:
This equipment
generates, uses, and can radiate
radio frequency energy, and if not installed
and used in accordance with the Instructions
Manual, may cause interference with radio
communication. It has been tested and found
to comply with the limits for a Class B
computing device pursuant to Subpart J of
Part 15 of FCC Rules, that are designed to
provide reasonable protection against such
interference when operated in a residential
and commercial environment. Operation of
this equipment in a residential area is likely
to cause interference, in which case, users
at their own expense will be required to take
whatever measures may be required to
correct the interference. Any unauthorized
modification of this equipment may result in
the revocation of the owner's authority to
continue its operation.
WARNING:
Fire Safety and Liability
Notice: Never connect card readers
to any critical entry, exit door, barrier,
elevator or gate without providing an
alternative exit in accordance with all fire and
life safety codes pertinent to the installation.
These fire and safety codes vary from city to
city and you must get approval from local fire
officials whenever using an electronic
product to control a door or other barrier.
Use of egress buttons, for example, may be
illegal in some cities. In most applications,
single action exit without prior knowledge of
what to do is a life safety requirement.
Always make certain that any required
approvals are obtained in writing. Verbal
approvals are not valid. Wiring of door
strikes and locks would also accordingly
follow either a fail-safe or fail-secure
configuration.
WARNING:
Earth ground all
enclosures for proper installation. It is
mandatory to use body earth on the terminal
of the fingerprint reader.
WARNING:
Exit switch wiring must
be completed within the protected
area or not readily accessible outside the
protected area.
WARNING:
Use suppressors on all
door locks. Use 14507020-001 diode
suppression network. Honeywell
recommends only DC locks.
CAUTION:
If the bus wiring enters or
exits the building, the protectors listed in
Installation Manual must be used. Bus length
for RS485 must not exceed 500m end-to-
end.
This equipment complies with FCC radiation
exposure limits set forth for an uncontrolled
environment .This equipment should be installed
and operated with minimum distance 20cm
between the radiator& your body.