background image

Installation Instructions for the

PX2 Series Heavy Duty Transducers

Issue 8

50052336

Sensing and Control

CAUTION

PRODUCT DAMAGE

  

Ensure torque specifications are determined for the specific

    application. Values provided are for reference only. NPT ports 
    are not specified with torque values. Correct installation 
    is based on the number of Turns From Finger Tight (TFFT).  
    (Mating materials and thread sealants can result in  
    significantly different torque values from one application to 
    the next.)

•  

When using NPT ports in stainless steel manifolds, use 

    a thread sealant with anti-seize properties to prevent thread 
    galling. Ensure the sealant is rated for the application.

•  

Use appropriate tools (such as an open ended wrench or 

    deep well socket) to install transducers.

•  

Always hand-start transducers into the hole to prevent cross 

    threading and damage.

•  

Do not subject the transducer to high temperatures from 

    soldering, brazing, or welding of the system plumbing 

Failure to comply with these instructions may result in 
product damage.

Ratiometric voltage devices require either a regulated 3.3 Vdc (AA 
and AB) or a regulated 5.0 Vdc supply (AC and AD), (see Table 2). 
All other versions can use an unregulated supply within the ranges 
noted under the excitation specifications. Ensure the power supply 
is off while wiring.

ELECTROMAGNETIC ENERGY/NOISE

CAUTION

PRODUCT DAMAGE/ERRATIC OPERATION

•  Do not use in areas where electromagnetic energy may affect

 

    transducer operation.

Failure to comply with these instructions may result in 
product damage.

The PX2 Series has been rated for high immunity to electrical 
noise; however, care should be taken when used around high 
voltage sources that emit high levels of radiated electromagnetic 
energy like variable frequency motor drives, solenoids, radio 
transmitters and engine ignition systems. The use of shielded 
cable and grounding of pressure port is also recommended.

FUNCTIONAL TEST

1.   Connect the transducer to a dc voltage supply (off). The supply 
      voltage should be set within the range specified for the model. 
2.   Based on the transducer’s specified output, connect the output 
      lead(s) to a digital dc or mA meter. 
3.    With no pressure on the transducer, turn on the power supply 
      and read the output signal on the voltmeter. The reading  
      should correspond to the specification indicated for null offset.  
      If not, check the connections, wire color code and the setting 
      of the power supply.

GENERAL INFORMATION

Honeywell’s PX2 Series Heavy Duty Pressure Transducer is 
a portfolio of highly configurable pressure sensors that use 
piezoresistive sensing technology with ASIC (Application Specific 
Integrated Circuit) signal conditioning in a stainless steel housing. 
The PX2 Series is fully calibrated and compensated for offset, 
sensitivity, temperature effects and non-linearity using the on-
board ASIC. 

OVERPRESSURE

CAUTION

PRODUCT DAMAGE

  Do not exceed the overpressure.

Failure to comply with these instructions may result in 
product damage.

If the overpressure rating is exceeded, the life of the PX2 Series 
may be reduced and electrical failure may occur. Both static 
and dynamic overpressure must be considered, particularly in 
hydraulic system applications. Hydraulic pressure fluctuations 
can have very high and very fast peak pressures, as in a water 
hammer effect. 

An oscilloscope is recommended for determining if high-pressure 
transients exist in a system. If system pressure pulses are 
expected, choose a transducer with a pressure rating high enough 
to allow continuous operation at the highest expected pressure 
spikes.

A pressure ‘snubber’ may be used to reduce the peak pressure 
applied to the transducer.

MEDIA COMPATIBILTY

CAUTION

PRODUCT DAMAGE

•  

Use non-abrasive, chemically compatible media to prevent 

    damage to diaphragm or port materials.

Failure to comply with these instructions may result in 
product damage.

The PX2 Series fluid path is an assembly of 304 stainless steel, 
epoxy, alumina, glass, and silicon.

•  

INSTALLATION

Table 1. Compatible Media

Refrigerants

Other Media

R410A
R134A

R123ZE

mixture of R245Fa and transdichloroethylene

engine oil 10W30

brake fluid DOT3 

hydraulic fluid

tap water

compressed air

Summary of Contents for PX2 Series

Page 1: ... supply voltage should be set within the range specified for the model 2 Based on the transducer s specified output connect the output lead s to a digital dc or mA meter 3 With no pressure on the transducer turn on the power supply and read the output signal on the voltmeter The reading should correspond to the specification indicated for null offset If not check the connections wire color code an...

Page 2: ...m4 2 kOhm Absolute voltage ratings5 minimum6 maximum6 maximum applied to output pin short circuit protection 7 16 V 16 V Vs 16 V 30 V 16 V 30 V 12 V EMC rating8 CE compliance electrostatic discharge radiated immunity fast transient burst immunity to conducted disturbances radiated emissions 4 kV contact 8 kV air per IEC 61000 4 2 10 V m 80 MHz to 1000 MHz per IEC 61000 4 3 1 kV per IEC61000 4 4 3 ...

Page 3: ...to the product for it to remain in specification once pressure is returned to the operating pressure range Exposure to higher pressure may cause permanent damage to the product 6 Burst Pressure The maximum pressure that may be applied to the product without causing escape of the pressure media The product should not be expected to function after exposure to any pressure beyond the rated burst pres...

Page 4: ...n See Figure 3 Wetted materials port substrate adhesives electronics 304 stainless steel alumina ceramic epoxy glass silicon External materials housing connector UL 94 HB standard UL 94 V 0 optional cable jacket 304 stainless steel PBT 30 GF black PBT 30 GF natural beige TPE Installation torque per pressure port type See Figure 4 Table 5 Pressure ReferenceTypes Pressure Reference Description Absol...

Page 5: ...EC 61076 2 101 Mating Connector 4 POS TYPE D IP Rating1 IP65 IP67 absolute sealed gage versions IP65 vented gage versions Connector EN 175301 803C Mating Connector EN 175301 803C DIN 43650C 8MM IP Rating1 IP65 all versions Pin Voltage Output Current Output Pin Voltage Output Current Output Pin Voltage Output Current Output A GND RTN 1 V supply 1 GND RTN B V supply 3 GND RTN 2 V supply C Vout NC 4 ...

Page 6: ...onnector 24 AWG with TPE jacket Mating Connector Flying leads IP Rating1 IP65 IP67 IP69K absolute sealed gage versions Pin Voltage Output Current Output Wire Color Voltage Output Wire Color Current Output 1 GND RTN red V red supply 2 Vout NC black GND black RTN 3 V supply white Vout Notes 1 IP rating is determined by the electrical connector type chosen 2 Three wire cable is required for ratiometr...

Page 7: ...metry ISO 1179 1 Installation torque1 25 N m 18 4 ft lb Seal2 3 O ring Mating geometry ISO 6149 1 Installation torque1 25 N m 18 4 ft lb N1 1 4 18 NPT N2 1 8 27 NPT Seal pipe thread Mating geometry ANSI B1 20 1 Installation torque1 2 to 3 Turns from finger tight Seal pipe thread Mating geometry ANSI B1 20 1 Installation torque1 2 to 3 Turns from finger tight S1 9 16 18 UNF SAE J1926 3 S2 7 16 20 U...

Page 8: ... 401 Building No 5 JiuGe Business Center Lane 2301 Yishan Rd Minhang District Shanghai China Sales Direct 86 21 6401 6692 Email amall ameya360 com QQ 800077892 Skype ameyasales1 ameyasales2 Customer Service Email service ameya360 com Partnership Tel 86 21 64016692 8333 Email mkt ameya360 com ...

Reviews: