INSTALLATION INSTRUCTIONS

69-2471EF-01

VR9105V, F and VR9205V, F

Direct Ignition Gas Control with 

Integrated 1:1 Regulator

APPLICATION

The VR9105V, F and VR9205V, F series gas controls with 
1:1 gas/air regulator have been developed for application 
in domestic appliances with premix burners and automatic 
ignition. They have been optimized for direct ignition 
applications. VR9105V and VR9205V series gas controls 
with 1:1 gas/air regulator can be used alone in direct 
burner ignition application. A plug with an integrated 
rectifier circuit then has to be used on the gas control 
when working with AC voltage.

VR9105F and VR9205F series gas controls with 1:1 gas/
air regulator and integrated venturi manifold are gas/air 
mixing units that allows modulation of a premix burner with 
constant gas/air ratio. The modulation is accomplished by 
changing the fan speed. The venturi generates a negative 
pressure against ambient pressure by which the gas is 
drawn through the gas valve outlet. Detailed information 
about the Venturi Manifold can be found in the installation 
instructions 69-2484EF.

• Valve capacities are shown in Table 1.
• For suffix letter designation, see Table 2.

a

Capacity based on 1000 Btu/ft

3

, 0.64 sp gr natural gas at 1 in. wc pressure drop (37.3 MJ/m

3

, 0.64 sp gr natural gas 

at 0.25 kPa pressure drop).

b

Minimum and Maximum regulation is at the max fire. Minimum regulation at low fire is 18 KBtu/h at 0.7 in. WC outlet 
pressure.

a

For detailed information about Venturi Manifold see Installation Instruction sheet 69-2484EF.

SPECIFICATIONS

Body Pattern: 

See Fig. 1 anFig. 2.

Electrical Ratings:

Voltage and Frequency: 24 Vrac, 50/60 Hz.
Current Draw: 0.42 A.

Capacity: 

See Table 1.

Regulation Range: 

See Table 1.

Natural-LP Gas Conversion Kits: 

Valve is not 

convertible.

Approvals:

CSA Design Certificate. File # 158158

Table 1. Valve Capacity.

a

Model

Inlet x Outlet 

Size (in.)

CSA Certified 

Capacity 

CSA Certified Minimum 

Regulation

CSA Certified Maximum 

Regulation

KBtu/h

KBtu/h

KBtu/h

VR9105V, F

1/2 x END

140

40

b

200

VR9105V, F

1/2 x SIDE

VR9205V, F

1/2 x END

VR9205V, F

1/2 x SIDE

Table 2. Model Number Suffix Letter Designation.

Model Number 

Suffix Letter

Ambient Temperature 

Range

Pressure Regulator Type

V

32 °F to 158 °F

(0 °C to 70 °C)

Standard opening with integrated 1:1 regulator

F

Standard opening with integrated 1:1 regulator and Venturi manifold

a

Summary of Contents for VR9105F

Page 1: ...uctions 69 2484EF Valve capacities are shown in Table 1 For suffix letter designation see Table 2 a Capacity based on 1000 Btu ft3 0 64 sp gr natural gas at 1 in wc pressure drop 37 3 MJ m3 0 64 sp gr natural gas at 0 25 kPa pressure drop b Minimum and Maximum regulation is at the max fire Minimum regulation at low fire is 18 KBtu h at 0 7 in WC outlet pressure a For detailed information about Ven...

Page 2: ...cial steps may be required to prevent nuisance shutdowns and control failure due to frequent cycling severe environmental conditions related to moisture corrosive chemicals dust or excessive heat These applications require Honeywell Combustion Engineering review contact your Honeywell Sales Representative for assistance Review the following conditions that can apply to your specific installation a...

Page 3: ... shielding should be provided by the appliance manufacturer verify proper air circulation is maintained when the appliance is installed INSTALLATION When Installing this Product 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for y...

Page 4: ...to Control All piping must comply with local codes and ordinances or with the National Fuel Gas Code ANSI Z223 1 NFPA No 54 whichever applies Tubing installation must comply with approved standards and practices 1 Use new properly reamed pipe that is free from chips If tubing is used make sure the ends are square deburred and clean All tubing bends must be smooth and without deformation 2 Run pipe...

Page 5: ...former and other controls as required 3 Connect the control circuit to the gas control terminals 4 Ensure combustion chamber is free of gas before startup 5 Adjust thermostat heat anticipator to the rating stamped on valve operator Electrical Connection VR9105V F and VR9205V F can be connected to any standard direct ignition control with 110 Vac output by using rectifier plug 45900441 039 or 24 Va...

Page 6: ...er than to the appliance being checked Other appliances must remain off with the pilots extinguished or deduct their consumption from the meter reading Convert flow rate to Btuh as described in form 70 2602 Gas Controls Handbook and compare to Btuh input rating on appliance nameplate 3 IF CHECKING GAS INPUT WITH MANOME TER Make sure the plug is not connected to the coil connector before removing o...

Page 7: ...one complete cycle to make sure all controls operate properly MAINTENANCE Under normal circumstances no maintenance or service is required WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Do not disassemble the gas control it contains no replaceable components Attempted disassembly repair or cleaning can damage the control resulting in gas leakage SERVICE WARNING F...

Page 8: ...formation below describes a typical control application but the specific controls used and the procedures outlined in your appliance manufacturer instructions can differ requiring special instructions To Turn ON Appliance STOP Read the Warnings Above Before Proceeding 1 The lighting sequence on this appliance is automatic do not attempt to manually light the main burner 2 If the appliance does not...

Page 9: ...sont illustrées dans le Tableau 1 Pour le suffixe de référence consulter le Tableau 2 a Capacité basée sur 1000 Btu pied3 gravité spécifique de 0 64 gaz naturel chute de pression de 1 po c e 37 3 MJ m3 gravité spécifique 0 64 gaz naturel et chute de pression de 0 25 kPa b Régulation minimum et maximum à combustion maximum La régulation minimum à basse combustion est de 18 KBtu h à une pression de ...

Page 10: ...pes spéciales sont requises pour éviter les coupures intempestives et les pannes de régulateur dues à des mises en marche et arrêts fréquents des conditions environnementales rigoureuses liées à l humidité des produits chimiques corrosifs de la poussière et une chaleur excessive Ces applications nécessitent d être révisées par le département d ingénierie de la combustion de Honeywell contacter le ...

Page 11: ...ante maximum autour du régulateur ne dépasse pas les conditions de température de fonctionnement du régulateur Si l appareil fonctionne à de très hautes températures utiliser un isolant une protection et assurer une circulation d air adéquate pour protéger le régulateur Une isolation ou une protection adéquate doit être fournie par le fabricant de l appareil vérifier qu une circulation d air adéqu...

Page 12: ...n ventilée Monter le régulateur suffisamment haut au dessus du bas de l armoire pour éviter l exposition à des déversements ou des éclaboussures d eau Veiller à ce que la température ambiante ne dépasse pas les valeurs de température ambiante nominales pour chaque organe Couvrir le régulateur à gaz si l appareil est nettoyé à l eau à la vapeur ou avec des produits chimiques et pour éviter l accumu...

Page 13: ...structions générales ci dessous Si ces instructions diffèrent de celles du fabricant de l appareil suivre celles du fabricant RÉGULATEUR À GAZ RÉGULATEUR À GAZ HORIZONTAL COLONNE DESCENDANTE ALIMENTATION EN GAZ TUYAU ALIMENTATION EN GAZ TUYAU ALIMENTATION EN GAZ TUYAU 76 MM 3 PO MINIMUM 76 MM 3 PO MINIMUM COLONNE MONTANTE RÉGULATEUR À GAZ HORIZONTAL COLONNE DESCENDANTE 76 MM 3 PO MINIMUM COLONNE M...

Page 14: ...pourraient causer un retour de flamme dans le vestibule de l appareil 4 Avec le brûleur principal allumé appliquer une solution savonneuse épaisse sur les joints du tuyau y compris les douilles et l entrée et la sortie du régulateur 5 Si une autre fuite est détectée éteindre le régulateur à gaz et serrer les joints et les raccords du tuyau 6 Remplacer la pièce si la fuite ne peut pas être réparée ...

Page 15: ... allumeur à incandescence immédiatement ou suite au prébalayage Voir les spécifications du module d allumage direct 4 Minuter la durée de l étincelle Voir les spécifications du module d allumage direct 5 Après le verrouillage du module connecter l obturateur au connecteur de serpentin et s assurer qu il n y a pas de débit de gaz vers le brûleur principal 6 Régler le thermostat à une température in...

Page 16: ... chauffage Les informations ci dessous décrivent une application typique mais les régulateurs spécifiques utilisés et les procédures décrites dans les instructions du fabricant de l appareil peuvent différer nécessitant des instructions spéciales Pour mettre l appareil en marche STOP Lire les avertissements ci dessus avant de continuer 1 La séquence d allumage de cet appareil est automatique ne pa...

Reviews: