Assembly, Servicing & User Instructions
Warning: Only for outdoor use
The Hotspot Patio Heater Range
Spiral
Bullet
TECHNICAL DATA
Heat input
14kw (50) 11kw (37)
Gas consumption
0.9 kg/h
Category:
Main injector
Injector
Pilot injector
Inlet pressure
size
identification
size
I3B/P 1.95mm
0.25mm 30mbar
I3B/P 1.65mm
0.25mm 50mbar
I3+ 1.95mm
0.25mm
28/37mbar
APPLIANCE IDENTIFICATION
Material group:
11.02 Radiant heater
Manufacturer:
Hotspot
Trade name:
Hotspot
Type:
Bullet, Evolution and Terrace
Category and
DK, FI, NL, NO, SE
I3B/P – 30 mbar
country of
AT, DE
I3B/P – 50 mbar
destination
BE, ES, FR, GB, GR, IE, IT, LU, PT
I3+ – 28 / 37 mbar
Appliance Pin Number: 048BM - 0022 (conical) 048BM - 0018 (straight)
For UK use 37 mbar regulator with Propane Gas