background image

Region: Global       AP040510       REV1.3       © 2023 Hoymiles Power Electronics Inc.

01

2. Installation Steps

1. Accessories

Step 1. Plan and install the Microinverter

All accessories above are not included in the package and should be purchased separately.

The order of Step 1 and Step 2 can be reversed according to your planned needs.

- Use the AC Trunk Connector Unlock Tool to 

unlock the connector upper cover.

1 )

  Disassemble the AC Trunk Connector and remove the cable.

2 )

  Install the AC Trunk End Cap at one side of AC Trunk Cable (The end of AC Trunk Cable)

- Loosen the three screws with screwdriver. 

Untighten the cap and remove the cable.

*Note: 

HMS-2000D-4T Series Quick Installation Guide

A )

  Mark the position of each microinverter on the rail, according to the PV module layout.

Step 2. Plan and build the AC Trunk Cable

AC Trunk Cable is used to connect the microinverter to distribution box.

A )

  Select the appropriate AC Trunk Cable according to the spacing between microinverters. The connector spacing of 

the AC Trunk Cable should be close to spacing between microinverters to ensure that they are well-matched. (Hoymiles 

provides AC Trunk Cable with different AC Trunk Connector spacing.)

B )

  Determine how many microinverters you plan to install on each AC branch and prepare AC Trunk Connectors 

accordingly.

C )

  Take out segments of AC Trunk Cable as you need to make AC branch. 

B )  

Fix the screw on the rail.

C )  

Hang the microinverter (as shown on 

the right) on the screws, and tighten the 

screws. 

- Insert the AC Trunk End cap and screw the 

cap back to port, then tighten the cap.

- Plug the upper cover back to the Trunk 

connector.

4.0±0.5N·m

Mounting Torque : 9 N·m

click

Item

Description

A

AC Trunk Cable, 12/10 AWG Cable

B

M8 x 25 screws (Prepared by the installer)

C

AC Trunk Connector

D

AC Trunk Port Cap

E

AC Trunk Port Disconnect Tool

F

AC Trunk End Cap

G
H

AC Trunk Connector Unlock Tool

Grounding Accessory 

3. Leave at least 2 cm of space around the microinverter enclosure to ensure ventilation and heat dissipation.

4. Mounting torque of the 8 mm screws should be 9 N·m.Please do not over-torque.

5. Do not pull or hold the AC cable with your hand. Hold the handle instead.

Note:
1. There is an earth wire inside the wire cable and the grounding can be done directly by this wire.             
If external grounding is needed, the grounding accessories, as shown on the right, can be used to bond 
the mounting bracket to the racking. Torque each grounding cleat screw to 2 N•m.
2. Install the microinverter and all DC connections beneath the PV module to avoid direct sunlight, rain 

exposure, snow buildup, UV, etc. 

*Applicable to HMS-1600D/1800D/2000D-4T microinverters

A

B C

D

E

F

G

H

Reviews: