background image

v1
February 2004
Printed in the U.S.A.

Smart Array (A9890A) Cable Routing

The purpose of this document is to provide cable routing information when a Smart Array PCI-X RAID card (A9890A) 
is used to drive the embedded hard disk drives. The existing SCSI cable connected to the Channel A connector on the 
system board is relocated to the Channel A connector on the Smart Array PCI-X card installed in slot 1 (full-length slot) 
of the PCI cage. 

The SCSI cable is routed from the PCI cage under the power supply bracket and over the IDE cable, if installed, avoiding 
blocking the airflow of the chassis fans.

Refer to the 

hp integrity rx1600 Operation and Maintenance Guide

 for detailed instructions on powering down the 

server, extending the server from a rack, and removing and replacing covers and components. 

1. Disconnect the SCSI cable from the Channel A connector on the system board by pulling on the cable release strap. 
See figure 1.

Figure 1.  SCSI Channel A Connector on System Board

2. Remove the PCI cage from the server.

3. Remove any accessory card installed in PCI slot 2 (half-length slot).

4. Install the Smart Array PCI-X RAID card (A9890A) in PCI slot 1 (full-length slot).

5. Orient the PCI cage with the installed PCI-X RAID card component-side-up allowing routing of the SCSI cable.

See figure 2.

Figure 2.  Cable Routing on Smart Array Card and PCI Cage 

NOTE

If an optional management processor card is installed in the server, follow the 
instructions provided in the 

hp integrity rx1600 Operation and Maintenance Guide

 to 

remove the card, allowing access to the Channel A connector. Reinstall the card after the 
SCSI cable has been disconnected.

Channel A 

connector

Around heatsink

Exit parallel to 

connector

Channel A1

Under slot 2 connector