Power protection in the data center is critical to maintain up time, and the increased densities in data centers is driving the need for
uninterruptible power with increased power density, power efficiency, and flexibility. The HP RP36000/3 does just that. This pre-racked
uninterruptible power systems provides 36 kilowatts (KW) of power or 24KW with N+1 redundancy. Housed in a single rack cabinet, (HP
Rack 10000 Series G2 42U) it can be expanded to 60KW with N+1 simply by installing up to 3 additional RP12000/3 UPS Modules.
Digital signal processing, UPS paralleling, and a new On-line On Demand hybrid technology answer the demands for density,
redundancy, efficiency and flexibility.

On-line On Demand combines the high efficiency of a line interactive UPS, up to 97%, with the stability of a double conversion on-line
UPS when power fluctuates beyond acceptable limits. Hot swappable batteries and electronics modules and an automatic bypass
reduce MTTER (mean time to repair) - down time in the event service is needed.
 

RP36000/3 Front

RP36000/3 Rear

QuickSpecs

HP Parallel 3 Phase Uninterruptible Power Systems

Overview

DA - 12856   Worldwide — Version 9 — June 25, 2012

Page  1

Summary of Contents for RP36000/3

Page 1: ... up to 3 additional RP12000 3 UPS Modules Digital signal processing UPS paralleling and a new On line On Demand hybrid technology answer the demands for density redundancy efficiency and flexibility On line On Demand combines the high efficiency of a line interactive UPS up to 97 with the stability of a double conversion on line UPS when power fluctuates beyond acceptable limits Hot swappable batt...

Page 2: ...000 Series G2 42U rack with front and rear doors 4 RP12000 3 UPS Expansion Modules qty3 Models HP RP36000 3 HP RP36000 3 36000VA Three Phase NA Uninterruptible Power System AF438A HP RP36000 3 36000VA Three Phase INTL Uninterruptible Power System AF439A QuickSpecs HP Parallel 3 Phase Uninterruptible Power Systems Overview DA 12856 Worldwide Version 9 June 25 2012 Page 2 ...

Page 3: ...s battery recharge time and provides advance notice of pending battery failure With Enhanced Battery Management you have a lower total cost of ownership and receive the best in the industry protection for your critical equipment State of the art UPS Paralleling Technology Configured to order the HP RP36000 3 UPS ships with three HP RP12000 3 UPS Modules the power bus bar and the wiring cabinet ins...

Page 4: ... software module ups index html Remote Emergency Power Off Feature The HP RP36000 3 UPS includes an isolated REPO Remote Emergency Power Off port The REPO feature allows the power to the UPS outlets to be switched off from a remote location For more information refer the HP RP36000 3 UPS user manual Flexible output configuration Output may be hardwired to a remote power panel such as the HP Power ...

Page 5: ...gement module can be configured to send alert traps to HP Systems Insight Manager and other SNMP management programs or used as a standalone management system This flexibility enables you to monitor and manage UPSs through the network To facilitate day to day maintenance tasks the embedded management software provides detailed system logs The HP UPS Management Module provides remote management of ...

Page 6: ...for the first year of ownership includes parts and labor Warranty standard on all HP Uninterruptible Power System UPS units extends the advantage of a HP three year limited warranty by applying it to the battery before it actually fails Specifically the Pre Failure Battery Warning ensures that when customers receive the notification from their HP UPS that the battery may fail the battery is replac...

Page 7: ...fferings customers and resellers please visit us at http www hp com hps NOTE Additional information regarding worldwide limited warranty and technical support is available at http h18004 www1 hp com products servers platforms warranty index html NOTE The information contained herein is subject to change without notice and is provided as is without warranty of any kind NOTE The warranties for HP pr...

Page 8: ...ica Japan NA JPN 3 Phase Jumper Cable 460151 015 HP 5ft IEC309 516P International INTL 3 Phase Jumper Cable 460153 005 HP 10ft IEC309 516P International INTL 3 Phase Jumper Cable 460153 010 Rackmount Power Distribution Units PDUs and PDU options North America Japan HP 24A 3PH Modular Power Distribution Unit AF512A HP Single Input 3 Phase 24A Monitored Power Distribution Unit AF504A HP Dual Input 3...

Page 9: ...even across different aisles in the datacenter 383984 B21 NOTE These kits mount on the top of the 9000 and 10000 Series rack except the S10614 rack Kit color is graphite Rack Coupling Kit 10000 Rack Coupling Kit 248929 B21 NOTE Supported by both the Rack 10000 and Rack 10000 G2 series Supports 24 in and 600 mm floor tile spacing The kit is used to join two or more 10000 series racks of the same he...

Page 10: ...nfiguration 50 or 60Hz auto detecting at startup 50 or 60Hz auto detecting at startup Frequency regulation 0 1Hz free running 0 1Hz free running Load power factor range Lagging 0 7 Leading 0 9 Lagging 0 7 Leading 0 9 Total output voltage distortion 3 with IT loads PFC power supplies 5 non linear or non PFC power supplies 3 with IT loads PFC power supplies 5 non linear or non PFC power supplies Inp...

Page 11: ...3 lb 396 kg 100 lb 46 kg Total Chassis Weight with batteries and electronics 1274 lb 578 kg 307 lb 140 kg 1274 lb 578 kg 307 lb 140 kg ERM Weight 170 lb 77 kg 170 lb 77 kg Communications and Management Software compatibility Ships with HP UPS Management Module Ships with HP UPS Management Module Control Panel Two lines by 20 characters Four menu driven interface buttons Four status at a glance LED...

Page 12: ...ww hp com go green To recycle your product please go to http www hp com go green or contact your nearest HP sales office Products returned to HP will be recycled recovered or disposed of in a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product disassembly instructi...