K

DM-III Multitest Power Quality Recorders

Features:

 • True RMS (TRMS)  • Measures 

and records broad spectrum of power quality 
parameters: AC current, AC voltage to 600V 
including sags and surges, harmonics (THD 
and individual up to 49th),  active, reactive and 
apparent power and energy, peak demand, 
power factor, frequency measurement and 
phase sequence  • Works with single and three 
phase systems  • Detects and records voltage 
anomalies, sags and surges  • Built in scope 
displays waveforms  • Phase sequence indication  
• Records up to 64 parameters simultaneously  
• Man ual and programmable recording start  • Line 
or battery powered  • Megohmmeter functions: test insulation of wires, cables, 
transformers and electrical motors  • Safety ratings: CAT III 600V phase to 
phase, CAT III 300V phase to ground

Includes:

 • CTs  • Voltage leads  • Ground probes and leads  • PC software 

and download cable

705-1026-ND

 

(DM-III MULTITEST F) . . . . . . . . . . . . . . . . . . . . . . . . . .

$3484.20

Test Equipment

 

(Cont.)

INSULATION

3Ø Power Quality Recorder

Ground Resistance Tester / Megohmmeter

TEST

LOW Ω

GROUND
TEST

POWER
QUALITY

F1

F2

F3

F4

SAVE

MENU

ESC

HOLD
ENTER

Start
Stop

AMPROBE

DM-III MultiTest

R

DM-4 Power Quality Recorder

Features:

• True RMS (TRMS)  • Works with single (two and 
three wire) and three phase systems (Y and Delta)  
• Detects and records voltage spikes 100nS or slower  
• Detects and records voltage sags and surges  • Built 
in scope displays waveforms  • Records all parameters 
simultaneously  • Manual and programmable recording 
start  • Safety rating: CAT III 600V

Includes:

• Carrying case  • CTs  • Test leads  • PC software and 
download cable  • Remote User Interface (PDA) with 
protective hard case and interface cable

705-1024-ND

 (DM-4) 

. . . . . . . . . . . . . . . .

$3695.68

RS232

DM-4

Power Quality Recorder

Fast Blink* - Urgent message, connect to recorder immediately!

Note: Allow 10 seconds of start-up time (Fast Blink), after unit is turned on.

IR

TM

R

ON/OFF LED

Unit-ON-AC Power

MAX

RESET

ON/OFF

RECORD

CAT III 600V/CAT II 1000V

!

COM

V1

I1

I2

I3

V2

V3

1V~

AMPROBE

Unit-ON-Battery Power

Red Solid

Record

Low Battery

Slow Blink

Low Memory

Green Solid

STATE

RECORD LED

12V

Spike-E

DGC-1000A Clamp-on Ground
Resistance Tester

Features:

• Accurate ground resistance measurement from 
0.025Ω ~ 1500Ω  • TRMS current measurement  
• Continuity beep if the resistance is lower than 40.00Ω  
• Data logging capability: 116 records  • Individual 
data point recording  • User selectable high and low 
Ω audible alarms  • Auto power off  • Low battery 
indicator  • Large LCD display  • Safety rating: CAT III 
300V, CAT II 600V

705-1023-ND

 (DGC-1000A) 

. . . . . . . . .

$1479.33

HOLD
OFF

FUNC

REC

TMULD-300 Leak
Detector Kit

Features:

 • Locates arcing in an electrical 

system  • Transmitter “pressurizes” area 
with ultrasonic sound enabling the ULD-
300 to pinpoint leaks  • Applications include 
air tightness of cars or houses  • Useful 
in finding the ends of buried PVC pipes  
• Detects any pressurized gas leak regardless 
of type CFC’s, HFC’s, Nitrogen, etc.

Includes:

 • Ultrasonic transmitter  • Flexible 

tubing adapter  • Tubular extension   •  Pa rabola  
• Headphones

705-1037-ND

 (TMULD-300) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

$422.92

RANGE

OI

ULTRASONIC

LEAK DETECTOR

Model

ULD-300

BATTERY 
GREEN-OK
RED-LOW

X1
X10
X100

HIGH
LOW

10

8

6

4

2

7
6

8

HIGH
MED
LOW

POWER

ULTRASONIC

TRANSMITTER

MODEL
UT-300

MODE

OFF
ON

TH-2A Digital
Thermo Hygrometer

Features:

• Temperature readings
• Relative humidity measurement
• Max/Min with time stamp
• Data hold function 
• Selectable °C and °F readout
• Dual LCD display with bargraph indication
• Auto power off

705-1033-ND

 (TH-2A) 

. . . . . . . . . . . . . .

$84.54

MX/MN

HOLD

°C/°F

%RH

TEMP

Digital

i

TH-2A

Thermo

Hygrometer

R

AMPROBE

0   

       

     2 0

            

  4 0              60  

%RH

ºF

THWD-2 Digital Sling
Psychrometer

Features:

• Temperature readings
• Relative humidity measurement
• Dew point and wet bulb readings
• Max/Min with time stamp
• Selectable °C and °F readout
• Data hold function
• Dual LCD display with bar graph indication
• Auto power off

705-1034-ND

 (THWD-2) 

. . . . . . . . . . . . . .

$116.26

MX/MN

MEM

HOLD

READ

°C/°F

%RH

TEMP

DEW
WET

Digital

i

THWD-2

Sling

Psychrometer

R

AMPROBE

0   

      

     20

           

  4 0              6 0 

%RH

ºF

RC-120S Remcon Relay Switch

Features:

• Switches AC power ON and OFF using low voltage 
control circuit  • Built in transformer, no step down 
transformers necessary  • Single relay can be controlled 
by multiple switches and multiple relays can be 
controlled by a single switch  • AC voltage from 105V ~ 
125V  • AC current up to 6.5A

705-1032-ND

 (RC-120S) 

. . . . . . . . . . . . . . . . . . . . . .

$42.24

REMCON SOLID STATE

R

R

AMPROBE

R

CAT .  NO:  RC - 120 S

THIS  DEVICE   GENERATES  HEAT
READ  INSTALLATION   INSTRUCTIONS!

LOAD

HOT

NEUT.

UL

IND.

CONT.

EQ.

9 57 B

LISTED

120    VOLTS   AC  60HZ

A United Union Company

6.5   AMPS  RESISTIVE  LOAD
6.5   AMPS  TUNGSTEN LOAD
6.5   AMPS  BALLAST LOAD
1/4   HP  MOTOR LOAD

PATENT NO.

4,751,401

OTHERS 

PENDING.

PRM-3 Phase Sequence and
Motor Rotation Tester

Features:

• Use for phase sequence 
testing, three phase motor 
installation and maintenance  
• Checks motors for rotation 
direction  • Identifies the 
phase sequence of the three 
phase electrical system 

 

•   I n d i c a t e s   n o r m a l   o r 
reversed phases as well as 
loss of the phase

705-1031-ND

 (PRM-3) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

$105.69

A

V

PHASE

CAT  III 600V

NORMAL

LOW

ON/OFF

50V to 600V~

!

PHASE to PHASE

REVERSE

BATTERY

(ABC)

LOSS

B

C

PRM-3

Phase Sequence & Motor

Rotation Tester

R

AMPROBE

GP-2 Ground Resistance and
Resistivity Tester

Features:

• Measure earth ground resistance; 3 point or 2 point 
tests  • Automatically calculates resistivity; 4 point 
test  • Automatic voltage measurement prevents false 
measurements  • Automatically applies three testing 
frequencies for the most accurate readings  • Auto 
ranging  • 999 internal memory locations to store 
measurements  • RS-232 download to a personal 
computer  • Safety rating: CAT III 250V

Includes:

• Test leads  • Auxiliary electrodes  • Software  • Carrying Case

705-1027-ND

 (GP-2) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

$1585.07

DISP

OFF

EARTH
2 WIRES

EARTH
3 WIRES

RS

232

AVG

DIST

CLR

RCL

SAVE

ESC

GO

AMPROBE

GP - 2     GeoTest

R

AT-1000 Advanced Tracer

Features:

• Trace energized lines up to 300VAC 
or VDC  • Trace unenergized and open 
conductors  • Identifies breakers and 
fuses without powering down  • Locates 
shorts  • Identifies wires in a bundle  
• Identifies control, alarm and telephone 
system wiring  • Traces coaxial cable 
shield  • Receiver range 1 to 3 feet from a 
cable being traced

Includes:

• Receiver  • Transmitter  • Carrying case  • 110V pigtail cordset  • Alligator 
clip cordset (2 pcs.)  • CT-326 type adaptor

705-1018-ND

 (AT-1000) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

$370.04

AT-3000 PRO Underground Hawk Buried Wire 
and Pipes Tracer

Features:

• Locates underground energized 
and de-energized wires, cables and 
pipes  • Depth measurement up to 10 
feet  • Visual (LCD) and audible (with 
loudspeaker) indicators  • Rugged 
durable construction  • Backlight  
• Real Sound Technology - the sound 
is derived from the signal radiating 
from the cable or pipe  • Ready for use 
with receiver, transmitter, connection 
cable, ground stake and ground 
cable  • Allows user to pinpoint the 
path of the underground traced object  
• Weatherproof and drop resistant

705-1019-ND

 (AT-3000 

PRO) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

$2638.26

R-3000 PRO

R-3000 PRO

G-3000 PRO

R

AMPROBE

BT-250 

Break’r Trac’r™

Features:

• Identifies circuit breaker location  
• Works on all electrical systems from 
90 to 250 VAC  • Automatic sensitivity 
adjustment  • Quick and easy to use  
• Extremely accurate reading always 
finds the right breaker  • Safety rating: 
UL approved

Includes:

• Transmitter  • Carrying case  • Test leads  
• Socket adapter 

705-1022-ND

 (BT-250) 

. . . . . . . .

$105.69

Made in the USA

ON

OFF

Break’r

Trac’r

BT-250R

AC circuit

breaker identifier

AUTO

SENSITIVITY

ADJUSTMENT

Made in the USA

Transmitter for

Break’r Trac’r

Use on 90-2250VAC
25/ 50/60 Hz Circuits

C

US

LISTED

CIRCUIT TESTER

82X5

BT-250T

Megohmmeters

AMB-25

Features:

• Test insulation of wires, cables, transformers and 
motors  • Comes as a complete kit including test 
leads  • Internal memory

Specifications:
• Insulation resistance with 250, 500 and 1000 VDC 
test voltages:

 0 ~ 4.000 / 40.00 / 400.00 / 4000MΩ  

• 

Resistance:

 0 ~ 9999Ω

AMB-45

Features:

• Test insulation of wires, cables, transformers 
and electrical motors  • Comes as a complete 
kit including test leads and PC software  • Pro-
grammable timer  • Internal memory  • Safety rating: 
CAT III 600V

Specifications:
• Insulation resistance with 250, 500 and 1000 VDC 
test voltages:

 0 ~ 4.000 / 40.00 / 400.00 / 4000MΩ  

• 

Re sistance:

 4000Ω  

• AC/DC Voltage:

 600.0V

AMC-2

Features:

• Test insulation of wires, cables, transformers 
and electrical motors  • Does not require 
batteries or any external power supply, always 
ready for use  • Ohmmeter

Specifications:
• 500VDC Test Voltage: 

0 ~ 100MΩ ±5% Rdg 

@ (0.1 ~ 50MΩ) ±10% Rdg @ > 50MΩ

AMB-5KV-D

Features:

• Test insulation of wires, cables, 
transformers, electrical motors and 
generators  • Comes as a complete kit 
including test leads and PC software  
• Built in automatic voltmeter up 
to 5000V warns against hazardous 
energized systems  • Programmable 
setups of test voltages and timers

Specifications:
• Voltages: 

100V ~ 5000V

  • Resistance:

 100kΩ ~ 500GΩ  

• Voltmeter: 

0 ~ 

5000V ± (10% Rdg = 10 LSD) @ 0 ~ 500V ± (10% Rdg + 5 LSD) @ 500V ~ 
5000V  

• Memory: 

20 programmable setup configurations

705-1014-ND

 (AMB-25) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

$317.17

705-1015-ND

 (AMB-45) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

$475.79

705-1017-ND

 (AMC-2) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

$687.27

705-1016-ND

 (AMB-5KV-D) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

$2379.14

VG

K
M

RE

ME

AD

M

s

AC

m:

HOLD

MegaTest 1

MEG-OHM

MEG-OHMS

OHMS

MODEL

AMC-3

AMPROBE INSTRUMENT

MΩ : 1000V.

Ω : 6V.

OHM

200

100

5

0

20

10

5

2

1

0

.5

0.2

0

50

0

2

00

10

0

5

0

2

0

10

5

2

1

0

.5

0

TIF300HV Tic Tracer -
AC Voltage Detector

Features:

• Use to check fuses, break panels, power outlets,  
transmission lines, etc.

• Safety rating: UL, CE and MSHA Approved

705-1035-ND

 (TIF300HV) 

. . . . . . . . . . . . . . . .

$73.97

705-1036-ND

 

48” Hot Stick (TIF410A) . .

$105.69

AT-4004/AT4005 Advanced Wire Tracers

Features:

• One universal transmitter; automatically switches to work with either 
energized or non-energized systems  • Receiver not position sensitive  
• Traces live wires buried or hidden behind walls  • Locates breakers, neutrals 
and ground lines  • Pinpoints shorts, ground faults and broken wires  
• Clamp-on attachment injects signal for non-contact operation  • Safety rating: 
CAT III 600V

Includes:

• Hard carrying case  • Receiver  • Transmitter  • 110V pigtail - banana plug 
cord set  • Alligator clip - banana plug cord set  • Grounding test lead, 25 ft. 
with alligator clip  • Clamp-on transmitter accessory  • Rechargeable battery 
pack and battery pack recharger (AT4005CON Only)

705-1020-ND

 (AT-4004CON) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

$793.01

705-1021-ND

 (AT-4005CON) 

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  

$951.63

CAT III 600V MAX

SIGNAL LEVEL

ON/OFF

SIGNAL LEVEL

T-4000

TRANSMITTER

R

AMPROBE

R

R

MODE

SENSITIVITY

HI
MID
LOW

OPEN

LOW BATT

ON

SHORT

SIGNAL LEVEL

CON

ON/OFF

R-4000

RECEIVER

R

AMPROBE

AMPROBE

AT-4005CON