background image

Instruction Manual

Thermal Imaging Camera

Dongguan Xintai Instrument Co.,Ltd.

Add: Building F, No. 22 Yuhua Street, Hongye Industrial Zone,
Tangxia Town, Dongguan City, Guangdong Province
Postcode:523710
Tel:+86-769-82612006
Fax:+86-769-82612005
Website:www.hytechcn.com.cn    www.xintest.com.cn
www.xintest.en.alibaba.com
Email:kevin@xintest.com.cn

User Manual Version 1.0. September 12

2019.

HT-A8

HT-A9

Summary of Contents for HT-A8

Page 1: ...22 Yuhua Street Hongye Industrial Zone Tangxia Town Dongguan City Guangdong Province Postcode 523710 Tel 86 769 82612006 Fax 86 769 82612005 Website www hytechcn com cn www xintest com cn www xintest en alibaba com Email kevin xintest com cn User Manual Version 1 0 September 12 2019 HT A8 HT A9 ...

Page 2: ...mage Overlapping 2 Introduction to Image Sub menu 2 1 View Image 2 2 Delete Images 22 22 23 24 25 27 28 29 29 31 29 29 29 32 35 30 24 35 3 Introduction to Color Palette Sub menu 3 1 Color Palette Description 3 2 Application of Color Palette 4 Introduction to Emissivity Sub menu 4 1 Emissivity Description 4 2 Emissivity Setting 4 3 The Emissivity Value of Common Materials 5 Introduction to Setting ...

Page 3: ... Xintai Instruments and Apparatus Co Ltd to obtain the authorization information for return Then post the product together with problem description to the service center with postage and insurance expenses prepaid Our company will not undertake any responsibility for any damage occurred during the process of transportation The product will be posted to the purchaser after repair with the transport...

Page 4: ...ge the product Don t assemble or dismantle the product without permission The product is a type of super precise equipment Don t try to dismantle assemble or remodel any part of the product Repair of the product should be made by technical personnel designated by Xintai Company Avoid damage to probe of the product Note don t put the product close to strong heat source directly such as electric iro...

Page 5: ...ous consequences Do not touch the electric wire with wet hands It is possible to cause electric shock when touching the electric wire with wet hands When pulling out the electric wire hold the electric wire head rightly to pull out the wire Don t pull off the electric wire directly Otherwise the electric wire may be broken causing electric shock and fire Forbid dip the product into water caught in...

Page 6: ...se power it off immediately Otherwise the instrument may be damaged Operation is not allowed unless the water condensation disappears For a long time infrared thermal imaging detection technology has become an important means to ensure Industrial safety in developed countries The application field includes electric power metallurgy petro chemistry machinery coal traffic fire control and national d...

Page 7: ... professional optical glasses Lens Maintenance Prevent damage of the infrared lens Clean the lens The following major functions increase the product s accuracy and usability The radiation coefficient may be adjusted to increase the measurement accuracy of objects with half reflection surface The highest temperature and lowest temperature cursor may guide the users to the areas with highest and low...

Page 8: ...will display Please charge in time through Micro USB interface www xintest com cn 11 www xintest com cn 12 Infrared image resolution Visible image resolution LCD resolution Field angle Thermal sensitivity Temperature measurement range Measurement accuracy Emissivity Frame rate of thermal images Wavelength coverage Focus mode Color palette 300000pixel Adjustable from 0 01 to 1 00 8 14um Fixed Rainb...

Page 9: ...ture Storage temperature Relative humidity Working time Built in chargeable 26650 battery Detachable Selectable 5 minutes 20 minutes not power off automatically 0 to 45 20 to 60 85 RH 3 4 hours JPG Setting command Language Unit language date time information USB Micro USB 2 0 1 www xintest com cn 13 www xintest com cn 14 Storage capacity Built in 8G Actually available 6 6G 588g 256mm 97 2mm 128 9m...

Page 10: ...f the screen Battery Micro USB Please open the cap in use 2 www xintest com cn 15 www xintest com cn 16 The highest temperature cursor used to indicate the highest temperature position in the screen area It will move with the movement of the highest temperature The cursor displays red The temperature value is displayed at bottom left corner of the screen Maximum value minimum value of field temper...

Page 11: ...ower the screen shows the thermal imaging status Witching between infrared thermal image and visible image press or key to switch the degree of fusion between inferred thermal images and visible images the degree of fusion is 0 25 50 75 and 100 Note Time adjustment may be required when you move the camera between environments with widely varying ambient temperatures Image capture Press the image c...

Page 12: ...ding mode Note If there is no operation for more than 6 seconds the image blending mode will be automatically exited The function to hide highest lowest temperature column at the screen bottom under the operation after normal start up press key and the screen bottom will display highest lowest temperature column Press can also hide it Image output The saved images through capture may be checked an...

Page 13: ... object with selection of different color palettes Press the MENU button to enter the main menu and select image in the main menu 171229 105030 171229 105031 171229 105032 171229 105033 The palette can be used to change the pseudo color display of the infrared image on the display Some tune Swatches are better suited for specific applications and can be set up as needed The palette is divided into...

Page 14: ...rect measurement value The emissivity is usually set as 0 95 when the coarse objects that are easy to give out energy For semi matte objects that give out less energy the emissivity is usually about 0 85 and the emissivity of semi gloss objects is 0 6 The shiny objects are divided into materials with low radiation coefficient The emissivity is usually set as 0 3 at the time of measurement Correct ...

Page 15: ...ect 0 85 Semi shiny object 0 60 Shiny object 0 30 According to the characteristics of the measured objects users may set the emissivity value through the self define option please refer to the table of emissivity of common materials If you select self defined emissivity press the SELECT ENTER button to enter the editing state Press keys to select the number to be changed press keys to change the v...

Page 16: ... the setting sub menu www xintest com cn 27 www xintest com cn 28 Thermal radiation 0 90 0 98 0 94 0 96 0 90 0 92 0 96 0 92 0 96 0 96 0 98 0 90 0 95 0 90 0 94 0 94 0 80 0 90 0 89 0 91 0 93 0 96 0 83 0 98 0 98 0 75 0 80 0 96 0 80 0 95 0 97 0 94 0 90 0 70 0 94 0 81 0 78 0 78 0 82 0 90 0 85 0 95 Black cloth Human skin Foam Charcoal dust Paint Matte paint Black rubber Plastic Timber Paper Chromium hem...

Page 17: ...nters the auto power off setting Can be set to not automatically shut down or 5 points The clock is turned off or turned off in 20 minutes As shown in the figure after selecting set time press in the navigation key to enter the setting time After selecting brightness press the button in the navigation key to enter the brightness setting Can be set to low or medium or bright 5 3 Language Settings A...

Page 18: ...tion After the setting is completed press key to return Press MENU key to exit from the menu 5 8 Wireless WIFI on and off As shown in the figure after selecting WiFi press the button in the navigation key to enter the WIFI setting www xintest com cn 31 www xintest com cn 32 Press key to select on or off the option Then press SELECT ENTER key to determine selection After the setting is completed pr...

Page 19: ...aximum minimum value language conversion and synchro nize to the machine The settings on the machine can also be synchronized to the mobile device Note if not converted on the mobile Refresh on the device Click on the photo on the mobile device and the image is saved on the machine as shown below Click Image in the mobile device to enter the image view press the image to download the image long pr...

Page 20: ...problems during the use process our company suggests that you familiarize with the user manual of the product first before the product is used The following conditions are not within the warranty scope 1 Unable to show the original of effective warranty voucher 2 The product installation does not comply with product requirements and relevant specification which causes damage 3 The damage is caused...

Reviews: