Part Number: 

Quick Start

HUAWEI NIP6830 Network Intelligent Protection System

31508202

Summary of Contents for NIP6830

Page 1: ...Issue 04 Date 2018 11 07 Part Number Quick Start HUAWEI NIP6830 Network Intelligent Protection System 31508202 ...

Page 2: ...e or email your comments about a document to us Notice The purchased products services and features are stipulated by the contract made between Huawei Technolo gies Co Ltd and the customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and reco...

Page 3: ... Cables Connecting AC Power Cables Connecting DC Power Cables Installing Fiber Spools Installing Boards and Daughter Cards Mounting and Grounding Installing Cabling Racks and Mounting Ears Installing Floating Nuts and Guide Rails 5 Configuring Console Access Power On Check AC Power Power On Check DC Power Installation Checklist 2 ...

Page 4: ...dundancy Airflow clearance The spacing between the air intake of the cabinet and neighboring objects must exceed 75 mm If the air intake of the cabinet is next to another communication device the spacing must exceed 150 mm Maintenance clearance The spacing between the rear of the cabinet and neighboring objects must exceed 350 mm for maintenance Aisles in the equipment room 1000 mm aisles between ...

Page 5: ...Requirements Installing Floating Nuts and Guide Rails DC cabinet AC cabinet 1U Location of floating nuts for guide rails M6 The third hole in rack unit 3 for device The first hole in rack unit 6 for device The second hole in rack unit 7 for fiber spool The second hole in rack unit 8 for fiber spool 1U Location of floating nuts for guide rails M6 The third hole in rack unit 3 for device The first h...

Page 6: ... racks Distance L is between 90 mm to 100 mm Distance L is between 115 mm to 120 mm L 1 Before installing the mounting ears measure the distance L between mount ing bar and the front door The way the mounting ear is installed depends on distance L as shown in the following figures Install the mounting ears 2 M4 Note M4 M4 5 ...

Page 7: ... ground resistance is zero ohm The NIP6830 is heavy and requires two people to lift and move Use the handles on the chassis sides when moving the device Do not use the handles of modules to avoid damages to the device Do not step on the air filter at the bottom of the cabinet Warning Mounting and Grounding 18kg 39 7 1b M6 6 ...

Page 8: ... insert the board fully into slot and rotate the ejector level to the front of the board so that the board is fully inserted in the slot Use a Phillips screwdriver to tighten the captive screws to the board Remove the filler panel from the board Smoothly insert the daughter card into the board along the guide rail Use a Phillips screwdriver to tighten the captive screws to the board 2 3 1 1 3 2 a ...

Page 9: ...ls based on the device arrangement in the cabinet The fiber spools cannot be too close to device operation area to avoid hampering board insertion or removal or cabling and the fiber spools cannot be too far away from the device to facilitate fiber spool operation Note Installing Fiber Spools Install the fiber spool left Install the fiber spool right M6 M6 8 ...

Page 10: ...of cable routing The air filter can not be covered by cables 请按示意图走线 线缆不得遮挡防尘网 STATUS Don t touch the fan leaves before they slow down 严禁在风扇高速 旋转时接触扇叶 RUN NEG RTN ALM ON OFF OFF ON 48 60V 42A RUN NEG RTN ALM ON OFF OFF ON 48 60V 42A Power A A1 A1 A2 A2 B1 B1 B2 B2 Power B Power A A1 PWR0 NEG PWR0 RTN Power A A1 Power B B1 PWR1 NEG PWR1 RTN Power B B1 From To Power A A1 Power A A1 PWR0 RTN PWR0 NEG...

Page 11: ...wer cables ensure that the device is adequately grounded Before connecting the power cable switch power off on the power distribution box and power module Do not work on cables with power to avoid bodily injury or fire Connecting AC Power Cables OFF ON OFF ON OFF ON Power A Power B C19 straight female PI angle male 16A 250V PD 013 PWR0 PWR1 Power A PWR0 Power B PWR1 From To a b b HUAWEI R4850G 100...

Page 12: ...CT MPU NIP MPU X3 RUN ALM ACT RESET OFL LINK CLK TOD MGMT ETH CONSOLE T X 5 4 R X S T A T U S 0 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3 0 1 1 0 1 2 2 2 2 3 1 1 1 3 NIP 24XGE SFP When handling optical fibers do not stand close to or look into the optical fiber outlet directly without eye protection Warning Connecting Optical Fibers and Network Cables Management ter...

Page 13: ...t touch the fan leaves before they slow down 严禁在风扇高速 旋转时接触扇叶 RUN NEG RTN ALM ON OFF OFF ON 48 60V 42A RUN NEG RTN ALM ON OFF OFF ON 48 60V 42A Rear view of the DC cabinet PWR0 PWR1 RUN ALM ON OFF OFF ON RUN Green steady on Red off ALM STATUS Blinking green STATUS Turn on the circuit breakers of external DC power supplies A and B Measure the input voltage of the device with a multimeter and ensure ...

Page 14: ...通信网络之前均须先接地 Air Filter STATUS Don t touch the fan leaves before they slow down 严禁在风扇高速 旋转时接触扇叶 PWR0 PWR1 Front view of the AC cabinet Rear view of the AC cabinet OFF ON RUN Green steady on ALARM Red off STATUS Blinking green STATUS Turn on the external AC power supplies A and B Measure the input voltage of the device with a multimeter and ensure that the voltage falls within the range of 90 V AC t...

Page 15: ...and daughter cards are installed in correct slots Pass Fail 5 Cable racks mounting ears and fiber spools are installed as required Pass Fail 6 The AC or DC power cable is correctly connected to the device Pass Fail 7 Fiber and network cables are correctly connected to the device Pass Fail 8 After the device is powered on indicators of all modules are normal Pass Fail 9 Filler panels are installed ...

Page 16: ...avigation tree on the left and configure the serial connection parameters Set Serial line to connect to according to the model of your PC Click Open to access the CLI 2 Click Enter on your PC and enter the user name admin and password Admin 123 to access the configuration view 3 b a c a b c COM3 COM3 AUX ACT LINK CLK TOD MGMT ETH CONSOLE 4 5 3 2 1 HUAWEI R4850G OFF ON 100 120V 200 240V 50 60Hz 16A...

Page 17: ...e larger than 150 mm the door thickness must be smaller than 25 mm and the spacing between the mounting rails and the door must be larger than 125 mm The cabinets can be accessed from both the front and rear doors and the porosity of the doors must be greater than 50 The cabinets must have necessary accessories such as guide rails floating nuts and bolts Determine the cable outlet locations based ...

Page 18: ... 200 mm and the cables must be fixed to the cabinet The cables must be labeled 20 mm away from both ends Label location Ports 20mm 1 A01 2 A 09 TO 1 A01 2 A 08 TO 1 A01 2 A 07 TO 1 A01 2 A 06 TO Cable Fold to the right Fold upward Labeling process Sticky side Cable Cable 1 A01 2 A 06 TO Do not tie cables at bends Do not cut ties in a way that creates pointed ends Cables must be neatly tied Cable m...

Page 19: ...Huawei Technology Co Ltd Huawei Industrial Base Bantian Longgang Shenzhen 518129 P R China www huawei com ...