background image

1

USER MANUAL 

GLT80TDC

User manual for 24-42V
Direct Current Compressor GLT80TDC

Summary of Contents for cubigel GLT80TDC

Page 1: ...1 USER MANUAL GLT80TDC User manual for 24 42V Direct Current Compressor GLT80TDC ...

Page 2: ...either on holidays at work or in any other cir cumstance where a DC powered air conditioner is utilised The GLT80TDC is designed to operate silently efficiently and reliably even up to angles of tilt of 20º and works with the refrigerant R134a Its design is based on Cubigel Compressors L series which has been successfully present in the market since 1964 and has had sales of more than 200 million ...

Page 3: ... to be programmed so Smart Speed can be easily used in all appliances with no design efforts FDC3 electronic driver includes Sleep and Sleep Energy Saving as programming option which are plug in systems specially conceived for mobile air conditioners avoiding any other electronic device Sleep and Sleep Energy Saving make the air conditioner work for four hours since start up Sleep Energy Saving ma...

Page 4: ...tion RECOMMENDED POSITIONS NOT RECOMMENDED POSITIONS β max 20º α max 15º Fig 1 Maximum tilt angle If compressor has been stopped during a certain period of time with an inclination higher than 15º it is strongly recom mended to not start up the compressor immediately after coming back to the correct position We recommend wait ing at least 30 minutes before starting up the compressor Off road appli...

Page 5: ...L AS THE APPLIANCE FRAME A FUSE MUST BE PLACED BETWEEN THE POLE OF THE BATTERY OR DC POWER SUPPLY AND THE POWER INPUT TERMINAL OF THE ELECTRONIC DRIVER 12V SYSTEMS 30A FUSE 24V SYSTEMS 30A FUSE 42V SYSTEMS 20A FUSE In some special vehicles chassis is connected to ter minal of the battery instead of terminal positive refer ence systems In such cases should be understood as and vice versa In systems...

Page 6: ...the FxC programming package hardware and software pro vided by Huayi Compressor Barcelona under request Op tionally the SPI can be configured to Install a LED to display the intervention of any alarm Set up either the compressor speed or the battery protec tion level through physical connections between IN1 IN2 and COM Connect the electronic driver as slave to an Electronic In tegral Manager of th...

Page 7: ...4V Special programming option The compressor can be powered by a variable DC source as for instance a photovoltaic panel in which the output voltage strongly depends on the intensity of sunlight radia tion In these special cases the driver should be programmed with rated minimum and maximum voltages These values should be within the allowable DC voltage power supply 10 V to 42 4V Rated voltage and...

Page 8: ...means of the serial port of a PC connected to the SPI port of the electronic driver using the FxC programming package provided by Huayi Compressor Barcelona under request In that option cut out and cut in values must re spect the rule defined by Table 2 In Table 2 ΔV is the difference between cut out and cut in that is the cut in value is the result of adding ΔV to the cut out value Externally usi...

Page 9: ...o or greater than the maximum nominal voltage 14V 28V and 42V for 12V 24V and 42V systems respectively A linear function of the battery voltage in the range between the cut in and the maximum nominal voltages This option is particularly useful for eutectic plates systems If external switching is programmed the speed is set up by the connection of the SPI connector terminals IN1 and IN2 to COM for ...

Page 10: ...g mode Compressor will run during four hours During first hour com pressor will run at selected speed During next three hours speed will decrease up to 2 000 r p m Programming Sleep Energy Saving is done in the same way as Sleep Slave mode Under this mode variable speed is controlled by an Electron ic Integral Manager of the appliance EIM permanently con nected to the electronic driver FDC3 throug...

Page 11: ...speed selection is incompatible with external battery protection step 8 2 7 2 Smart Speed mode Select maximum fixed speed or external switcher connected to SPI and proceed as de scribed in 7 1 1 or 7 1 2 respectively 7 3 Sleep and Sleep Energy saving modes Select maximum fixed speed or external switcher connected to SPI and pro ceed as described in 7 1 1 or 7 1 2 respectively 7 4 Slave mode 8 Sele...

Page 12: ... attempts to restart is unlimited Once the sequence of automatic attempts to restart the compressor is finished the unit will remain permanently un able to operate until it is switched off and on again from the power supply The intervention of the thermostat during the sequence of automatic restart attempts interrupts and resets the sequence The SPI can be configured in a way that a LED can be con...

Page 13: ...kg 10 2 Oil type ISO VG 22 ESTER Oil charge cm3 330 Reliability GLT80TDC pass following reliability tests High Temperature according with CECOMAF GT 4002 standard Wear according with CECOMAF GT 4003 standard ON OFF according with CECOMAF GT 4004 standard Vibrations according with ASTM 5728 Level I standard Application Application MBP HBP A C Refrigerant R134a Evaporation temp range ºC 25 to 10 Exp...

Page 14: ...ure Compressor overload Electronic driver overheat Programmable running modes Standard Smart Speed Sleep Sleep Energy Saving Slave Setup by default Running mode Standard Speed selection external switcher Lower higher speed 2000 3500 r p m Battery protection fixed voltage level standard system Cut out 12 24 42 V systems 12 22 38 5 V Cut in 12 24 42 V systems 10 8 20 0 36 2 V 3 minutes thermostat de...

Page 15: ...20 pieces pallets r p m T evap 25ºC T evap 10ºC T evap 7 2ºC Q kCal h COP Q kCal h COP Q kCal h COP 2 000 100 1 15 228 1 64 497 2 34 2 500 123 1 13 285 1 62 613 2 26 3 000 145 1 11 341 1 58 725 2 17 3 500 166 1 09 392 1 54 834 2 07 r p m T evap 25ºC T evap 10ºC T evap 7 2ºC W I A W I A W I A 2 000 101 4 21 162 6 75 247 10 3 2 500 127 5 29 204 8 5 315 13 1 3 000 152 6 33 251 10 5 388 16 2 3 500 177...

Page 16: ...16 Huayi Compressor Barcelona S L Antoni Forrellad 2 08192 Sant Quirze del Vallès BCN Spain Phone 34 93 710 60 08 Fax 34 93 710 69 58 www huayicompressor es USER MANUAL GLT80TDC 08 2021 ...

Reviews: