background image

P.O. Box 60080 

 16555 East Gale Ave.

City of Industry, California 91716-0080

626/968-56

66 • FAX 

626/330-3861

Revised 

7

/

16

/10        ECN 

100715008

        Status 6 Part No. 95642

INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR INJURY TO PERSONS

IMPORTANT SAFETY INSTRUCTIONS!

WARNING:  Fixtures must be grounded in accordance with local codes or the National Electrical Code.

Failure to do so may result in serious personal injury.  All work should be done by a qualified electrician.
SAFETY WARNING:  Lighted lamp is HOT!  Do not touch lens, guard, or enclosure.  Do not operate 

luminaire with missing or damaged lens.

MAINTENANCE:  For optimum performance a regularly scheduled maintenance program should be followed.

See page 3 for furthur maintenance instructions.  KEEP THIS SHEET FOR FUTURE REFERENCE.

LTV57
LTV58
LTV757
LTV758

Tools Required: 

J

" Hex Socket Wrench

F

" Hex Socket Wrench

K

" Open End Wrench

Philips Screwdriver

Silicone Grease

IMPORTANT:

Condensation inside the fixture is a common occurrence due to the expanding and condensing of the

trapped air inside the fixture as it is cycled on and off.  When the lamp is energized during the evening hours, moisture
on the inside of lens will burn off as fixture heats up.  It will reappear after power is shut off and the inside air condenses
during cooling.  A large majority of this moisture can be avoided by following the installation guide lines as described in
the housing installation instructions.  Always relamp fixture during low humidity periods.  Before closing fixture, remove
desiccant from zip lock bag and place in reflector compartment. Energize the lamp for approximately five (5) minutes to
dry air inside fixture.  Install lens and lens frame as described below.

LENS FRAME / REFLECTOR INSTALLATION: 

Make certain electrical supply is 

OFF

before starting fixture installation.

!

1. Remove debris shield from

housing & discard.  (Shield is
aluminum, please recycle.)

2. Place dessicant package inside

housing before connecting quick-
disconnect.

!

LIGHTVAULT

®

- LTV Lens Reflector

Installation Instructions

!

3. Connect housing quick-disconnect

to reflector assembly quick-
disconnect.