INSTRUCTION MANUAL TRIAC DIMMER [R,L] – 879 410 LED
Technical Features
Safety instructions
Supply voltage
230 V, 50 Hz
CAUTION!! DANGER OF LIFE / RISK OF FIRE AND ELECTRIC SHOCK!!
Installation and assembly of electrical equipment must be carried out only by
professional electrician!
Connect to supply voltage/frequency as stated on the product!
Disconnect device from power supply for wiring and installation purposes! Check power supply is disconnected!
Defective devices have to be put out of service immediately!
Warranty void if housing opened by unauthorized person!
Electronic circuit is protected against a wide range of external influences. Incorrect operating may occur if external influences exceed certain limits!
Installation and assembly of electrical equipment must be in accordance with local building and electrical codes!
Important note
When calculating the max. load please take into account power dissipation of transformers: For conventional transformers ~20% power dissipation /
For electronic transformers ~2% power dissipation.
For all transformers and lamps, please take into account the specifications of the manufacturer!
Intended use
The device fits for the particular use of the following tasks: dimmer for the previously defined lamps.
Operate the device in a closed room only! The regulation of the brightness operates as described in the instruction manual.
The device is equipped with a overheat protection and short-circuit protection.
Power consumption
3 VA
Type of lamps
dimmable LED lamps
LOAD
S
Dimmable 230 V LED lamps
for leading edge
4 - 1200 W
Max. number of pushbuttons
unlimited
(no illuminated pushbuttons)
Dimensions
87,5 x 87,5 x 60 mm
Weight
400 g
Working temperature
0 º … +40 ºC
Storage temperature
-30 º … +70 ºC
Type of protection
IP20 nach DIN EN 60529
According to the norm
DIN EN 60669-2-1
Description / Installation
Operation
Description / Intended use
TRIAC dimmer for DIN-rail mounting
Use with dimmable LED lamps
For leading edge
The device is equipped with a overheat protection and short-circuit protection.
Unlimited number of pushbuttons (no illuminated pushbuttons), potentiometer (internal or external) or 0 - 10V
signal.
Seven basic functions (MEM, NO MEM, MEM PLUS, 0 - 10V, SLAVE, int. & ext. potentiometer).
Check the technical specification of the lamps! For all transformers and lamps, please take into account the
specifications of the manufacturer!
Installation
CAUTION!
You must select the correct type of connected load in order to avoid damages of the
dimmer or the lamps!
1. Set an operating mode with the lateral rotary knob.
2. Disconnect device from power supply for wiring and installation purposes! Check power supply is
disconnected!
3. Mount the dimmer on the DIN-rail of the electric cabinet. Avoid placing it next to other sources of heat.
4. Carry out the wiring according to the selected operating mode.
5. Reconnect the power supply. The dimmer is ready for operation.
Anti-panic function
If you open the contact between the two terminals, the dimming function
overloads and the installed load/loads illuminate with maximum power.
You need this function especially in emergency situations. With removing
the bridge, the dimmer goes to maximum load and does not react to standard commands. If you do not use this
function, you have to keep the bridge between the terminals closed. The dimmer works in the standard mode
then.
Operation / functionality
The dimming can be performed with different controls, depending on the
configuration selected:
SLAVE Master-Slave Mode
Potentiometer (intern or extern)
MEM Pushbutton operation – Memory function
NO MEM Pushbutton operation – No memory function
MEM PLUS Pushbutton operation – Memory function with
additional safety function in case of power failure
0-10V Signal 0 - 10V
Protection against over heat
Protection against over heat switches off the lamps.
Note:
If the dimmer is switched off due to over heat protection, please try to:
Reduce the output load.
Install the dimmer inside an electric cabinet with forced ventilation or without other heat sources,
or place it in the lower part of the cabinet, where the accumulation of heat may be lower.
Selector switch for LED lamp type
The device has a selector switch with 3 modes of operation: LEDA, LEDB, LEDC.
Change the selected mode if you notice that the LED lamps blink or change light level
suddenly at
some point of the dimming. Select the mode that fits to the characteristics of your LED
lamp best.