INSTALLATION

PROJECT:

LOCATION:

SUBMITTED BY:

FAN MODEL

DOWNROD

WALL CONTROL

VARIABLE FREQUENCY DRIVE

NOTES

*Available upon request.
Fan(s) will be located at the nearest location(s) as per building plans.
Wall control location(s) to be identified by owner at time of installation.
IF INSTALLATION IS TO BE PERFORMED BY OTHERS: Installation and site preparation to be performed by others at owner’s request.
IF GOLD LEVEL INSTALLATION: Basic mechanical installation includes: scissor lift rental (if necessary), mounting all fans and equipment, routing all
communication cables, connecting fans and controls (if applicable) to power supply, and factory authorized startup and commissioning.
**CUSTOMER IS RESPONSIBLE FOR PROVIDING POWER SUPPLY TO 15’ FROM EACH FAN LOCATION PRIOR TO FAN INSTALLATION*
IF PLATINUM LEVEL INSTALLATION: Full turnkey installation includes: routing all electrical wire and conduit from each fan location to electrical
panel, terminating electrical connections with NEMA rated receptacles, scissor lift rental (if necessary), mounting all fans and equipment, routing all
communication cables, connecting fans and control (if applicable) to power supply, routing low voltage fire relay cable from each fan location to security
panel (if fire relay tie-in is required – Customer’s fire/security company to land final connections), and factory authorized startup and commissioning.

DIAMETER

COMMENTS

P: 629.333.7100  |  F: 615.232.3891  |  TOLL: 1.844.591.FANS (3267)

 

180 THREET INDUSTRIAL ROAD, SMYRNA 37167

  | 

HUNTERFAN.COM/INDUSTRIAL

24"

36"*

48"*

To Be Performed By Others

Gold Level Installation (Basic Mechanical)

Platinum Level Installation (Premium Turnkey)

7'8 '

10 '

12 '

14 '

Summary of Contents for XP 10

Page 1: ...PPLY TO 15 FROM EACH FAN LOCATION PRIOR TO FAN INSTALLATION IF PLATINUM LEVEL INSTALLATION Full turnkey installation includes routing all electrical wire and conduit from each fan location to electrical panel terminating electrical connections with NEMA rated receptacles scissor lift rental if necessary mounting all fans and equipment routing all communication cables connecting fans and control if...

Page 2: ...INCLUDED CERTIFICATIONS ETL Intertek certified to ANSI UL 507 and CSA C22 2 No 113 in North America Limited Lifetime on Airfoils 2 year Warranty parts only Rigid Mount with pre wired downrod Control Panel Install Manual Airfoils 350 Series Fan Controller Wall Control Mounting Hardware Kit Communication Kit 3 and 4 Rigid Mount downrod Additional Control Cable Lengths Glulam brackets WARRANTY1 1 See...

Page 3: ...olders when installing or cleaning the fan DO NOT insert foreign objects in between rotating fan blades Installation Adjustment Repair or Maintenance Must Be Performed By Qualified Personnel Follow all safety practices and instructions during the installation operation and servicing of the fan Failure to apply these safety practices could result in death or serious injury If you do not understand ...

Page 4: ...ctory and are ready to use No user adjustments are available Follow the included installation instructions when installing this device to ensure proper operation Do not make any changes to any part of the fan without first consulting Hunter Industrial Fan Installation is to be in accordance with ANSI NFPA 70 National Electrical Code and local codes The user is responsible for compliance with all i...

Page 5: ...g structure to withstand double the maximum hanging weight of the fan a professional structural engineer should perform a thorough evaluation of the building prior to purchasing the fans Hunter Industrial Fan provides guidelines for mounting fans however it is the sole responsibility of the building owner and installer to ensure the safety of the mounting system and Retention Cable the building st...

Page 6: ...rson cannot reach the rotating blades in any way Position fans so that the tips of the blades are at least 5 feet away from any area where a person may be able to extend outward to reach them Lights and Skylights If possible avoid mounting fans directly below lights or skylights to avoid any strobe effect caused by moving blades There should be a minimum of 2 feet between the blades and any light ...

Page 7: ...AMETER MINIMUM CLEARANCE FAN PLACEMENT FAN SPACING CHART A MIN MAX DIA A B XP 35ft 56ft 10 67m 17 07m 14ft 427cm 10ft 305 cm 12ft 366cm 8ft 244 cm 7ft 213 cm 25ft 40ft 7 62m 12 19m 30ft 48ft 19 14m 14 63m 20ft 32ft 6 10m 9 75m 18ft 28ft 5 49m 8 53m B ...

Page 8: ...hot water or regular cleaning solutions DO NOT use chlorine or any chemicals containing chlorine or the blades may be damaged Retention System Check Each fan is installed with a retention system Every 12 months check that the Retention Cable is properly attached to the building structure Inspect the visible portions of the Retention Cable for damage including fraying The Retention Cable is an impo...

Page 9: ...9 IN THE BOX FAN COMPONENTS A B C A 1 Downrod B 1 Motor C 4 Blades D 1 Control Panel E 1 Standard Control F 1 Communication Cable G 1 Installation Manual not shown D E F ...

Page 10: ...tion Can be daisy chained to control up to 5 fans 3 5 LCD Touchscreen Alert Readouts Plug n Play design Standard junction box Simple flush mounting 2 73 69 31 2 00 50 80 3 95 100 31 3 05 77 44 3 55 90 14 0 203 4 places 5 16 2 06 52 26 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERFAN COM INDUSTRIAL ...

Page 11: ...ly from screen Most cost effective network controller NUMBER OF FANS CONTROLLED ACTIVE DISPLAY AREA RESOLUTION DIMMING PROTECTION CLASS INPUT VOLTAGE UP TO 10 FANS 4 3 DIAGONALLY 480 X 272 DIAGONAL DIMMABLE TO 0 IP66 100 VAC 240 VAC 4 3 TOUCHSCREEN 430 SERIES TOUCHSCREEN CONTROLLER 4 30 109 31 5 88 149 31 UP TO 10 FANS 3 59 91 20 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTE...

Page 12: ...cheduling grouping and fan naming Fan diagnostics directly from screen NUMBER OF FANS CONTROLLED ACTIVE DISPLAY AREA RESOLUTION DIMMING PROTECTION CLASS INPUT VOLTAGE UP TO 30 FANS 7 DIAGONALLY 480 X 272 DIAGONAL DIMMABLE TO 0 IP66 100 VAC 240 VAC 700 TOUCHSCREEN 5 18 131 60 7 69 195 20 4 04 102 70 CONTROL 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERFAN COM INDUSTRIAL ...

Page 13: ...and BACnet IP IP67 BTL CE FCC CLASS B C PART 15 UL 60950 IC CANADA ROHS AND WEEE COMPLIANT PTCRB AND CTIA OPERATING ENVIRONMENT TEMPERATURE OPERATING ENVIRONMENT HUMIDITY INPUT VOLTAGE ENCLOSURE RATING CERTIFICATIONS 20 TO 70 C 4 TO 158 F 10 95 RH NON CONDENSING 24VAC 125MA 12 24VDC 250MA 12VDC BACNET GATEWAY 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERFAN COM INDUSTRIAL ...

Page 14: ...802 3AB 802 3X FOR GIGABIT ETHERNET CE CSA EICC UL E200031 ROHS 2 COMPLIANT OPERATING ENVIRONMENT TEMPERATURE OPERATING ENVIRONMENT HUMIDITY INPUT VOLTAGE MAX POWER ENCLOSURE RATING CERTIFICATIONS 40 TO 75 C 40 TO 167 F 10 95 RH NON CONDENSING CLASS 2 POWER SUPPLY 12 48VDC 18 30VAC 50 60HZ BACNET GATEWAY OPTIONS FOR CONTROLS 14 180 THREET INDUSTRIAL ROAD SMYRNA TN 37214 1 844 591 FANS 3267 HUNTERF...

Page 15: ...er voltage Breaker Size Chart Electrical Plug Requirements Voltage 110 120V L5 15R L5 15P Plug Receptacle A Plug and Receptacle are included with each fan XP AMP DRAW Fan Diameter AC 1PH 100 120V 50 60Hz Recommended Breaker Size 14 7 5A 6 2A 10A 12 8 4A 7A 15A 10 9 1A 7 6A 15A 8 5 2A 4 2A 10A 7 6 7A 5 5A 10A ...

Page 16: ...Connect a wire from terminal S to SB on the Fire Relay Terminal Strip Connect a wire from terminal C to C on the Fire Relay Terminal Strip Apply 12 40VDC from Fire Panel to Fire Relay Input Relay has a 20mA draw NORMALLY ENERGIZED On the Terminal Strip mounted to the outside of the VFD enclosure a Jumper will be in place on terminals S and C Remove the Jumper from terminals S and C Connect a wire ...

Page 17: ...MAXIMUM Normally Energized Unenergized Dry Contacts VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure with Fire Relay Fire Panel 10 40VDC VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay VFD Enclosure without Fire Relay Fire Panel Normally Closed 17 ...

Page 18: ...18 XP 10 2 0 10 0 0 5 10 0 ...

Reviews: