(white)
(Black)
(Purple)
(Grey)
120/240V (RETRO) CONNECTIONS
Make input connections according to diagram below.
INPUT: 100-277VAC
(white)
(Black)
REMOTE DRIVEN (SERIES) CONNECTIONS
Make input connections according to diagram below.
DRIVER OUTPUT:
CONSTANT
CURRENT 700mA
Max, 37Vdc
POSITIVE
NEGATIVE
NOTE: THESE INSTRUCTIONS MUST NOT CONTRAVENE YOUR
LOCAL ELECTRICAL AUTHORITY REGULATIONS, WITH WHICH
ALL INSTRUCTIONS HERE IN MUST COMPLY.
PLEASE KEEP INSTRUCTIONS FOR FUTURE REFERENCE.
ULTRA 35 Pole Spot
Installation instructions
Warning: Do not connect secondary side (output) of a live driver to
the Fixture. This will cause a spike in voltage that can damage the LED.
When connecting or disconnecting the fitting always insure the
120/240V power supply is disconnected.
When using a photocell and/or timer we recommend using devices
with relay outputs as opposed to electronic. The high frequency of
electronic devices can lead to failure of the LED driver.
Follow the diagram opposite to correctly instal Ultra 35 Pole spot.
Remove the Pole Spot head from the pole by un-doing the three fixing
screw at the top of pole. This will allow you to pull the head with
bracket and top cap free.
We recommend casting the pole into the ground with concrete to a
minimum depth of 300mm (12”). Be sure to place free draining
material
in the base of the hole. This will allow water to drain away and stop the
water level building up in the pole.
NB. top of the pole is indicated by the 3 grub screw holes
Once ground works are complete and the pole is correctly set into
place draw power supply and dimming cables up through pole. Allow
for 200mm (8”) extra above top of the pole. Make waterproof
connections to the luminaire input cable and dimming cable. A non
waterproof connection will allow water to ingress into power supply
and/or fixture head which can lead to failure.
See diagrams below for correct wiring
Finish installation by securing the Luminaire Head/Cap to the top of
pole with the three fixing screws.