background image

DBP, DBRP 01, 03

ISLAND PRODUCE

P/N IGIP-DBP, DBRP 01, 03-0508

INSTALLATION & OPERATION GUIDE

/CHINO

DBP

, DBRP

 01, 03

ISLAND PRODUCE 

RE

v. 0508

Installation 

 

& Operation 

 

Manual

Summary of Contents for DBP-03

Page 1: ...DBP DBRP 01 03 ISLAND PRODUCE p n IGIP DBP DBRP 01 03 0508 INSTALLATION OPERATION GUIDE CHINO DBP DBRP 01 03 ISLAND PRODUCE Rev 0508 Installation Operation Manual...

Page 2: ...s Information on DBP DBRP 01 03 Island Produce Cases Shipping Damage All equipment should be thoroughly examined for shipping damage before and during unloading This equipment has been carefully inspe...

Page 3: ...ain Ref 6 24 16 26 1 8 DBRP 03 Shown with Optional Ref High Center Divider and Refrigerated Lighted Shelves Scale 3 8 30 Optional Ref High Center Divider and Ref Lighted Shelves Optional Base Display...

Page 4: ...ty are maintained at or below 75 F and 55 relative humidity DO NOT allow air conditioning electric fans ovens open doors or windows etc to create air currents around the merchandiser as this will impa...

Page 5: ...and outside rear mullion on both cases to be joined 5 Apply liberal bead of case joint sealant butyl to dotted area shown in figure first case Apply heavy amount to cover entire shaded area DO NOT US...

Page 6: ...means to prevent freezing The water seal should be insulated to prevent condensation Hose Reel If an optional hose reel is ordered it will be installed at the factory The water supply valve is locate...

Page 7: ...rator outlet 2 From a refrigerant pressure temperature chart determine the saturation temperature at the observed suction pressure 3 Measure the temperature of the suction gas at the thermostatic remo...

Page 8: ...in and around the case area free of foreign gasses and fumes or food will rapidly deteriorate 3 Maintain the display merchandisers temperature controls as outlined in the refrigerator section of this...

Page 9: ...orescent Lamps Fluorescent lamps are furnished with a shatterproof protective coating The same type of lamp with protective coating must be used if replaced This lamp has been treated to resist breaka...

Page 10: ...that no outside doors or windows are open allowing moisture to enter store FOR PROMPT SERVICE When contacting the factory be sure to have the Case Model and Serial Number handy This information is on...

Page 11: ...01 CASES W0500000 CROWN CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH T...

Page 12: ...00001 2 POINT CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 0...

Page 13: ...OINT CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01 0329 BU...

Page 14: ...SES W0500003 8 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125...

Page 15: ...004 10 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01 0329...

Page 16: ...S W0500005 12 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 0...

Page 17: ...6 14 CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01 0329 BU...

Page 18: ...07 9 OCTAGON CASE WIRING DIAGRAM 115 VAC 50 60 Hz L1 N BUNDLE COLOR BLACK WHITE T STAT SUCTION SOLENOID VALVE FIXTURE LITHONIA SM132 125 02 1072 FIXTURE LITHONIA SM125 125 02 1073 SWITCH TOGGLE 125 01...

Page 19: ...SSMANN CORPORATION 13770 RAMONA AVENUE CHINO CA 91710 909 590 4910 LIC 644406 1 2 3 1 1 04 08 05 T WIRESCHEMATICS NEW WIRING DBRP 03 8 W0500008 DBRP 03 8 COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 2...

Page 20: ...N CORPORATION 13770 RAMONA AVENUE CHINO CA 91710 909 590 4910 LIC 644406 1 2 3 1 1 04 08 05 T WIRESCHEMATICS NEW WIRING DBRP 03 32 W0500020 DBRP 03 32 COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 225...

Page 21: ...HRH 561536 COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 225 02 0040 M M TERMINAL BLOCK 125 01 0295 L1 L2 L3 N G DEFROST TIMER PARAGON 8045 20 208 V 60 Hz 125 01 0715 M YELLOW C 2 1 3 R S POWER 208 230...

Page 22: ...HRH COIL PGS 2 3 6 115V 1 PHASE 50 60HZ 1 34 AMP 225 02 0040 M M TERMINAL BLOCK 125 01 0295 L1 L2 L3 N G DEFROST TIMER PARAGON 8045 20 208 V 60 Hz 125 01 0715 M YELLOW C 2 1 3 R S POWER 208 230 VAC 6...

Page 23: ...6B GE FAN 9W 4 125 01 0615A 60A CONDENSING UNIT COPELAND FJAM A150 CFV 020 225 03 7510 RLA 10 9A MCC 15 7A LRA 56 A M C R CONDENSING UNIT SAFETY SWITCH FLOAT SWITCH FISHER EVAPOWAY DM20WW 3D 2000W 240...

Page 24: ...installer should perform a complete start up evaluation prior to the loading of food into the refrigerator which includes such items as a Initial temperature performance Coils should be properly fed...

Page 25: ...product 2 Is the product loaded beyond the Safe Load Line markers 3 Are the return air ducts blocked 4 Are the entering air ducts blocked 5 Is a dumped display causing turbulent air flow and mixing wi...

Page 26: ...temperature recovery Food store refrigerators are not food chillers nor can they reclaim quality lost through previous mishandling d Care must be taken when cross merchandising products to ensure that...

Page 27: ...___________________________ _______________ ___________________________________________________________________________________________________ _______________ ________________________________________...

Reviews: