P/N 0475958

Item Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

7W

Fan Assembly

(1)

Fan Motor, Evaporator

0058698

Standard (120V, 60Hz) 

0439052

Energy Efficient Fan (120V, 60Hz)

0436516

Export (230V, 50 Hz)

0142780

Fan Blade, embossing toward motor

B. 0411744

Standard Non-adjustable

(2)

Defrost Thermostat

C. 0353949

Optional Adjustable 

(3)

Refrigeration Thermostat

Item Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D. 0466234

Ballast, Electronic

2 lamps

(4)

D. 0466235

Ballast, Electronic

3 lamps

(4)

D. 0466236

Ballast, Electronic

4 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

HUSSMANN CORPORATION, Bridgeton, MO  63044-2483  U.S.A.

Note: Changed items have been underlined.

E2V

Data Sheet Set

P/N  0475958

NSF

®

Certified

October  2005

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Summary of Contents for IMPACT Elite E2V

Page 1: ...g Item LAMPS AND BALLASTS D 0466234 Ballast Electronic 2 lamps 4 D 0466235 Ballast Electronic 3 lamps 4 D 0466236 Ballast Electronic 4 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures HUSSMANN...

Page 2: ...l 5 3 4 146 5 3 4 146 5 3 4 146 5 3 4 146 Electrical Service Electrical Field Wiring connection point B Length of electrical raceway 18 3 8 467 18 3 8 467 37 940 37 940 C RH End of case to center of f...

Page 3: ...F 18 21 Unit Sizing F 16 19 Btu hr ft Parallel 945 920 Conventional 1030 1000 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA Frequency hr 6 Defrost Water...

Page 4: ...Cycling Anti sweat Heaters NA Minimum Circuit Ampacity With Standard Fans 120V 60Hz 0 70 1 20 1 20 1 70 With Energy Efficient Fans 120V 60 Hz 0 46 0 72 0 72 0 98 With Export Fans 230V 50Hz 0 48 0 76 0...

Page 5: ...must have mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 2 3 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Case...

Page 6: ...nts in 12 foot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W BL...

Page 7: ...locations It is critical to case performance that no product shelf or stop extend beyond the load limit as shown in this illustration This configuration supports the air curtain and provides optimal...

Reviews: