background image

HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.

P/N 0457235B

Note:  

Changed items have been underlined.

Merchandisers

®

C

D

D

A

D

B

C

M4EP

LUS

Data Sheet Set

P/N 0457235B

NSF

®

Certified

March  2005

Item

Part #

Description

Wiring Item #

F

AN

A

SSEMBLIES AND

T

HERMOSTATS

A.

9W

Fan Assembly

(1)

0047000

Fan Motor, Evaporator 

0407532

Fan Blade
embossing toward motor

C.

0137880

Optional Adjustable 

(3)

Refrigeration Thermostat

Item

Part #

Description

Wiring Item #

L

AMPS AND

B

ALLASTS

D.

0428648

Ballast, Electronic

2 lamps

(4)

D.

0428649

Ballast, Electronic

3 lamps

(4)

E.

Fluorescent Lamp

(5)

Replace with like fixtures

We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.

Summary of Contents for M4EP

Page 1: ...e embossing toward motor C 0137880 Optional Adjustable 3 Refrigeration Thermostat Item Part Description Wiring Item LAMPS AND BALLASTS D 0428648 Ballast Electronic 2 lamps 4 D 0428649 Ballast Electronic 3 lamps 4 E Fluorescent Lamp 5 Replace with like fixtures We reserve the right to change or revise specifications and product design in connection with any feature of our products Such changes do n...

Page 2: ...e between inside edges of center supports NA 44 1118 Width of external support 4 1 8 105 4 1 8 105 Stub up area between front skidrail and splashguard 4 102 4 102 Right edge of case excluding end to inside edge of external support 1 3 8 35 1 3 8 35 Electrical Service Electrical Field Wiring connection point B Right end of case to center of farthest knockout 88 3 8 2245 136 1 2 3467 Back outside of...

Page 3: ...rge Air F 31 29 Evaporator F 28 26 Unit Sizing F 26 24 Btu hr ft M4EPLUS UNLIT LIT Parallel 1095 1185 Conventional 1190 1290 For all refrigeration equipment other than Hussmann use conventional Btu values DEFROST DATA Frequency Hrs 6 Defrost Water lb ft day 8 15 based on case configuration and product loading OFFTIME M4EPLUS Time minutes 30 ELECTRIC OR GAS Not Recommended CONVENTIONALCONTROLS Low ...

Page 4: ... Fans 120V 60Hz 3 00 4 40 Export 230V 50Hz 1 72 2 48 With Energy Efficient Fans 120V 60Hz 1 72 2 48 Maximum Over Current Protection 120V 20 20 Maximum Over Current Protection 230V 15 15 Supplemental Gas Heaters NA 208V 1Φ Φ Electric Defrost NA Standard Lighting 1 Row Canopy 0 51 0 77 59 85 Optional Lighting 1 Row Canopy and 1 Rail 1 02 1 54 118 170 2 Row Canopy 1 02 1 54 118 170 2 Row Canopy and 1...

Page 5: ...ve mechanical ground and the merchandiser must be grounded CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Fan Wiring Offtime Defrost 4 6 Fans 120V NEUTRAL BROWN BAND 120V POWER Fans 1 BROWN BAND Connector Connector G Connector Connector Connector Connector Connector Optional Shelf Harness and Light Circuits for One Row of Shelves 120 V Power B W G B BL BL BL G G R R BL BL G W BL Shelf Harness Shelf Light...

Page 6: ...ot models only R Red Y Yellow G Green BL Blue B Black W White CIRCLED NUMBERS PARTS LIST ITEM NUMBERS Optional Lighting 3 Row Canopy 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B B W 4 BL R R BL BL 3 BL R R BL BL 3 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V POWER ORANGE OR TAN BAND B BL R R BL BL 3 4 4 120V NEUTRAL ORANGE OR TAN BAND W Light Switch 120V ...