background image

13 

 

1 of 13 

RDI 

Technical Data Sheet 

 
 

Rev A

Specialty Products 

RDI 

    

  

 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

 
These merchandisers are manufactured to meet ANSI/National Sanitation 
Foundation Standard #7 requirements.  

We reserve the right to change or revise specifications and 
product design in connection with any feature of our 
products.  Such changes do not entitle the buyer to 
corresponding changes, improvements, additions or 
replacements for equipment previously sold or shipped. 

REFRIGERATION DATA 

Note: This data is based on store temperature and 
humidity that does not exceed 75F and 55% R.H.

 

 

 

 

 

 

Discharge Air (F) 

30 

 

 

Evaporator (F) 

20 

 

Note: Not recommended to control temp by regulating 
coil temp allow t-stat to cycle and control temp. 

 

 

 

 

 

 

 

 

 

Btu/hr/ft 
Parallel   

    750

 

   
Conventional             863 
 
 

 

*For all refrigeration equipment other than Hussmann, 
use conventional Btu values. 
 

DEFROST DATA 

Frequency Hrs  

 

 

OFFTIME  
Temp Term °F 

54 

Failsafe Minutes  

20 

          

 

ELECTRIC or GAS     Not Recommended 

 

 

 

PHYSICAL DATA 

Merchandiser Drip Pipe (in.) 

1 ½* 

Merchandiser Liquid Line (in.) 

3/8* 

Merchandiser Suction Line (in.) 

5/8* 

 

Estimated Charge (lb)*** 

4ft 1.2 
5ft 1.5 
6ft 1.8 
 

*Dependent on case length and refrigerant type. 

 

*** This is an average for all refrigerants types.  Actual 
refrigerant charge may vary by approximately half a 
pound. 

GLYCOL REQUIREMENTS 

   

 

 

 

  GPM           PSI 

 

 

 NA 

 

NA   

 

 

  NA         

NA 

 

 

 

  NA         

NA 

 

  

   

 

 CUL Listed

 

 

 

 

 

 

 

 

 

  

 

     UL Sanitation

 

 

 

Reviews: