background image

Users manual

EN

01.11.2020 / 97-9705

www.hwam.com

3740

3760

Summary of Contents for 3740

Page 1: ...Users manual EN 01 11 2020 97 9705 www hwam com 3740 3760 ...

Page 2: ......

Page 3: ...of contents Drawings 4 8 HWAM SmartControlTM 9 Installation 10 Firing manual wood 15 Firing in general 18 Maintenance 19 Operational problems 21 Declaration of Performance 22 Product information EcoDesign 23 ...

Page 4: ...d by Configuration name Item Status Scale D Model HWAM 3740 manual Thickness mm 4 3 2 I 4 5 I 4 3 I C Sheet1 A 27 04 2020 nis Frigivet Frigivet nis 04 05 2020 B Comment Init Date Rev Frigivet nis 07 05 2020 C nis 21 04 2020 DS EN 22768 m 1 10 A3 Com Released Created date Format Ite kg Part Weight Tolerance HWAM A S Nydamsvej 53 55 DK 8362 Hørning Tel 45 86 92 18 33 Fax 45 86 92 22 18 Material Crea...

Page 5: ...Page 5 of 20 pages D1 D2 ...

Page 6: ...Page 6 of 20 pages D3 ...

Page 7: ...Page 7 of 20 pages E 6 2 1 3 4 5 ...

Page 8: ...Page 8 of 20 pages F ...

Page 9: ... manuals for the app IHS Smart ControlTM or in the Quickguide Your new wood burning stove and the HWAM SmartControlTM will ensure the cleanest possible com bustion as well as a good fuel economy regardless of external conditions such as the type of firewood used the chimney the user s experience and other external circumstances The HWAM SmartControlTM consists of the following components Air box t...

Page 10: ...bustion air to the room where the stove is to be installed The woodburning stove uses approx 4 15 m3 of air per hour A window that can be opened or an adjustable air valve will be sufficient It must not be possible to block the adjustable air valve grate In newly built airtight dwellings we recommend that a fresh air system should be installed for the direct supply of external air to the combustio...

Page 11: ...cient draught and prevent any smoke nuisance As a general rule satisfactory draught conditions are achieved if the chimney is 4 m above the stove and at least 80 cm above the ridge If the chimney is placed at side walls the top of the chimney should always be higher than the ridge or the tallest point of the roof Always be aware of any national and or local regulations applying to thatched roofs a...

Page 12: ...talling the top plate of the stove 8 Place the top plate 8 on the fittings and secure it with the two screws 9 14 Installing the internal heat shield 6 Replace the heat shield 6 at the back of the stove 15 Installing the rear plate 3 Place the rear plate 3 on the guide pins at the back of the bottom plate of the stove then press it in towards the stove Lift the rear plate and press it lightly inwa...

Page 13: ...ront and the 2 screws 14 on each side of the front 18 Installing side Put the side 16 on the guide pins in the bottom plate of the stove and press it in towards the stove Lift the side and press it lightly inwards until it engages with the guide pins Secure the side with the two screws 17 19 Installing the top plate of the stove 8 Place the top plate 8 on the fittings and secure it with the two sc...

Page 14: ... temperature sensor Chimney The chimney is the engine of the stove and it is crucial for the functioning of the woodburning stove The chimney draft provides a partial vacuum in the stove This vacuum removes the smoke from the stove sucks air through the dampers in the Air box for the so called glass pane rinse which keeps the glass free of soot and for the combustion The chimney draft is created b...

Page 15: ...d give off more embers Light types of wood such as birch maple spruce and pine are more easy to light up They burn faster and give off fewer ambers You may therefore take advantage of the light types of wood for lighting and use the heavier types of wood to ensure a longer burning time Banned fuel types It is not allowed to stoke a fire with the following printed matter plywood plastic rubber flui...

Page 16: ...d when the stove is in use Otherwise the HWAM SmartControlTM does not function The door should only be opened when lighting up when restoking and when cleaning the stove Never leave a stove before there are lasting flames in the wood after firing TheThermostat Function The HWAM SmartControlTM will in general have an environmentally friendly combustion and adapt to the desired room temperature The ...

Page 17: ... wood that is used for restoking should be adjusted based on the current heat demand In terms of combustion technique you should always stoke the stove with at least two pieces of wood at a time even if you only use a small amount of wood You can also choose not to restoke After a while the stove will then automatically go in stand by mode During combustion the outer surfaces of the stove will bec...

Page 18: ...ve has been approved for intermittent use Typical re firing interval Typical re firing interval at nominal performance Wood 45 min 0 89 kg Long burning times You achieve the slowest combustion by setting the desired room temperature at level 0 At this level the combustion takes place with the lowest possible flue gas temperature and the ember phase will be drawn out as long as possible How to achi...

Page 19: ...ed twist the safety fittings for transportation off the two hooks by using pliers or a screwdriver TThe smoke shelf and baffle plate is to be removed from the stove before cleaning Drawing E First lift the smoke shelf 1 out of the steel rail 2 at the back of the combustion chamber Next lower it beneath the holders 3 and slide it out Lift each half of the steel smoke plate 4 off the holder 5 behind...

Page 20: ... however be remedied with spray paint which can be bought from your stove retailer Guarantee The guarantee does not cover damage due to insufficient maintenance Maintenance Alarms If a maintenance alarm goes off you can continue using the wood burning stove but contact your dealer as soon as possible Your stove could be affected by impure combustion ...

Page 21: ...may be closed Open the grate Insufficient chimney draft See section on chimney or contact chimney sweep Soot door leaking or dislodged Replace or refit Never open the door when there are still flames on the wood Uncontrollable combustion Faulty seal in door or ash pan Fit new seal Safety Alarms In case the safety alarms go off you must not use the stove Contact your retailer as soon as possible At...

Page 22: ...Page 22 of 20 pages Declaration of Performance The DoP can be downloaded from our website via the following links www hwam com dop 3700ihs ...

Page 23: ...tems correctly i e separate the parts to be disposed of in material groups 4 5 0 015 0 012 0 0015 83 4 111 A Specific Precautions during Assembling Installing Maintenance Product End of Life Recycling Always dispose of items in a way that is as sustainable as possible and that is in line with the current environmental protection reprocessing recycling and disposal technology Space heating performa...

Page 24: ...www hwam com ...

Reviews: