background image

Filters

FIL1609-1828 / 04.19

RFD Series 

Change-Over Return Line Filter

Service and Parts

up to 343 gpm (1300 l/min), up to 362 psi (420 bar)

NOTE:

Contamination or incomplete pressure release 

on disassembly can lead to seizing of the bowl 

thread.
Filter elements which cannot be cleaned 

must be disposed of in accordance with 

environmental protection regulations.

1. Maintenance

1.1 General

Please follow the maintenance instructions.

1.2 Installation

Before installing the filter into the system, check 

that the operating pressure of the system does 

not exceed the permitted operating pressure of 

the filter.  

Refer to the type code label on the filter.

1.3 Commissioning

Check that the correct filter element is installed. 

Install lid, screw in cover plate bolts alternately. 

Switch lever to one filter side. Switch on 

hydraulic system and vent filter.

1.4  Maintenance Tools

Size

Torque value 

Nm [ft-lb]

Int. Lid Screws 

hex bolt  

Allen key

60/110

20 Nm [14]

Hex 6

160/240

20 Nm [14]

Hex 6

330

40 Nm [29]

Hex 8

660

150 Nm [110]

Hex 14

950/1300

200 Nm [147]

Hex 17

1.5  Torque Values

Type

Torque Nm[ft-lb]

VR clogging indicator 30 [22]

1.6  Torque Values for Reservoir 

Mounting Bolts

Size

Torque Nm 

[ft-lb]

Bolt 

Size

RFD 60/110

5 [3.7]

M5

RFD 160/240

8 [6]

M6

RFD 330

20  [15]

M8

RFD 660

20  [15]

M12

RFD 950/1300

25  [19]

M16

for mechanical damage.

8. Check O-rings – and replace if necessary.

2.2 Element Installation

1. Lubricate the sealing surfaces on the filter 

housing and cover plate, as well as the 

O-ring, with clean operating fluid.

2. When installing a new filter element, check 

that the designation corresponds to that of 

the old element.

3. If present, install the contamination retainer 

onto the new or cleaned filter element by 

turning clockwise.

4. Place filter element carefully on to the 

element nozzle in the housing.

5. Sizes 60-330: 

Replace cover plate and screw in cover plate 

bolts by hand; then tighten bolts alternately.

  Sizes 660-1300: 

Replace cover plate in correct position 

(dowel pin in the housing must line up with 

groove in cover plate) and turn counter-

clockwise as far as it will go. Tighten cover 

plate bolts alternately.

6. Vent filter at an appropriate point in the 

system.

7. Check filter for leakage.

2.  Element Replacement

2.1  Element Removal

1. Switch lever slowly over to clean filter side.
  

Caution when installed inline: 

Before opening the filter, slowly open the 

vent screw and release pressure. 

(release pressure in the tank, if any)

2.  Size 60-330: 

Loosen cover plate bolts and lift off the cover 

plate.

  

Sizes 660-1300: 

Unscrew cover plate bolts by approx. 2 turns 

(no need to remove completely). Turn cover 

plate clockwise until it can be lifted off by 

holding near the bolts (bayonet fitting).

3.  Pull out filter element(s) (with contamination 

retainer, if present) by the handle. Examine 

element surface for dirt residues and larger 

particles since these can be an indication of 

damage to components.

4.  Remove contamination retainer (if present) 

by turning counter-clockwise – bayonet 

fitting.

5.  Replace or clean filter element(s) (only W/HC 

and V elements can be cleaned).

6. Clean housing, cover plate and 

contamination retainer.

7. Examine filter, especially sealing surfaces, 

Summary of Contents for RFD Series

Page 1: ...ng with clean operating fluid 2 When installing a new filter element check that the designation corresponds to that of the old element 3 If present install the contamination retainer onto the new or cleaned filter element by turning clockwise 4 Place filter element carefully on to the element nozzle in the housing 5 Sizes 60 330 Replace cover plate and screw in cover plate bolts by hand then tight...

Page 2: ...92 2 x 307622 2 x 1293042 2 x 1293039 1261127 1261128 2065071 2073676 3 1 O ring element 22 x 3 5 34 x 3 5 48 x 3 68 x 5 68 x 5 97 8 x 5 33 3 2 O ring cover plate 63 09 x 3 53 91 67 x 3 53 105 x 5 142 x 6 153 x 5 175 x 5 185 x 5 3 3 O ring indicator 18 x 2 5 3 4 O ring tank seal 82 14 x 3 53 110 72 x 3 53 00405588 03170653 03170653 00405590 4 Contamination retainer RF D 00245028 00246164 00245029 ...

Page 3: ...ly designed to minimize electrostatic charge generation Model Codes Containing RED are non stock items Minimum quantities may apply Contact HYDAC for information and availability 5 Replacement Clogging Indicator VR 5 D X V Indicator Prefix VR Return Filters Trip Pressure 2 29 psid 2 bar return filters 5 72 psid 5 bar optional Type of Indicator A No indicator plugged port B Pop up indicator auto re...

Page 4: ...are parts must fulfil the technical requirements specified by the manufacturer This is always ensured when using original HYDAC spare parts Keep tools working area and equipment clean After disassembling the filter clean all parts check for damage or wear and replace parts if necessary When changing a filter element a high level of cleanliness must be observed 6 4 Interval Between Element Changes ...

Page 5: ...5 FIL1609 1828 04 19 FILTER MAINTENANCE Notes ...

Page 6: ...CORPORATION Mobile Hydraulic Division 1660 Enterprise Parkway Suite E Wooster OH 44691 1 610 266 0100 HYDAC CYLINDERS LLC 540 Carson Road North Birmingham AL 35217 1 205 520 1220 HYDAC TECHNOLOGY CORPORATION HYDAC CORPORATION Sales Office Operations 510 Stonegate Drive Katy TX 77494 1 281 579 8100 HYDAC TECHNOLOGY CORPORATION HYDAC CORPORATION NW Sales Office Operations 1201 NE 144th St Bldg B Sui...

Reviews: