PRE-SPRAY AND TRAFFIC LANE APPLICATIONS:

 

Hydro-Force injection sprayers eliminate the has-

sles of measuring and mixing. We recommend you 
keep an extra 5-quart container or two on your truck 
to make sure you never run out and to facilitate quick 
changes of your chemical containers. Remember that 
Hydro-Force sprayers automatically mix at a 1 to 8 
ratio. If your 5-quart container is full then that is the 
same as holding an 11 gallon pump sprayer of regu-
lar, ready to use pre-spray. 
 

Hydro-Force injection sprayers offer better pene-

tration and overall coverage than other sprayers. It is 
therefore possible to pre-spray your jobs up to 45 
minutes before that area needs to be cleaned. An 
effective way to use the Hydro-Force sprayer for pre-
conditioning is to start at the door coming into the 
house; spraying all the traffic areas, and work your 
way to the farthest point back in your job. You have 
then completed your pre-conditioning in just seconds 
and are prepared to hook up your wand and start 
cleaning your way out.
 

On larger jobs, or jobs involving more than an 

hour of cleaning time, it is recommended that you 
pre-spray an area that will take no longer than 45 
minutes to clean. You can then hook up your Hydro-
Force again and pre-spray another large area.  

APPLICATION OF CARPET PROTECTORS: 

 

This highly profitable procedure is often passed 

up on many jobs because it is too big of a ‘hassle’. 
Operators will not mention the availability of protec-
tors because they are running short on time and must 
hurry to their next job, or they don’t want to take the 

time to rinse tanks then measure, mix and pump.
 

Hydro-Force injection sprayers bypass these has-

sles and encourage you to apply carpet protectors. Go 
to your machine, shut off the chemical and, if you pre-
fer, your heat. You should then take a 5 quart contain-
er with clean water (adding an ounce or two of acid 
or vinegar will help) to your Hydro-Force injection 
sprayer unit. Take off your traffic lane bottle and put 
on clean water. Run your Hydro-Force injection spray-
er for approximately 20 seconds or until all soap is out 
of your lines. You may then put on your 5 quart con-
tainer with carpet protector in it. Your product should 
be concentrated and diluted at 1 to 8 for application 
on damp carpet. If this is a difficult dilution to reach 
you may remove the metering tip to obtain a 1 to 4 
ratio. If you are using Scotchgard® or a Teflon® prod-
uct on dry carpet you should dilute them 1 to 1 with 
water before you use them with a Hydro-Force injec-
tion sprayer. Whether you use Maxim™ or another 
product, you will find that a 5 qt. container will go a 
long way. 5 qts. diluted 1 to 8, gives you 11 gallons of 
ready to apply protector. With a coverage rate of 300 
square. ft. per gallon, 5 qts. of protector will cover 
3,000 square ft. Keep in mind that your Hydro-Force 
injection sprayer is spraying 3 to 4 times the amount 
of product your normal pump sprayer is putting out. 
This means you must move quickly to avoid over-
applying. Protector should be applied in even, slightly 
overlapping strokes. You should proceed from the 
entrance again working your way toward the farthest 
point.

To learn how you can save time 

and money using a Hydro-Force sprayer 

call 800-637-3789 or visit www.hydroforce.com

Innovating since 1974

HYDRO-FORCE™ PRO

Injection Sprayer

Part Number: AS08

Patent Pending

www.hydroforce.com

I n j e c t i o n   S p r a y e r

PRO

PROBLEM: Will Not Draw Chemical

CAUSES

PART

SOLUTIONS

Inlet Strainer Clogged

NA0803

Clean or Replace

Wrong Teejet Size

B280

Replace

Acorn Strainer Clogged

NA0840

Clean or Replace

Metering Tip Clogged

NA0816

Clean or Replace

Water Nozzle Clogged or Worn

NA0808

Clean or Replace

Injector Valve Needs Major Rebuild

NA0849

Install Kit

Bad Injector Valve

NA0809A

Replace

PROBLEM: Container Backfills

Injector Valve Needs Rebuild

NA0841

Install Backflow Kit

Bad Injector Valve

NA0809A

Replace

PROBLEM: Does Not Shut Off or Leaks From Gun

Worn Gun

100010

Replace

Valve Needs Rebuild

NA031A

Replace

Worn Valve in Gun

NA031

Replace

TROUBLE SHOOTING GUIDE

The Hydro-Force injection sprayer is used to quickly, and evenly apply pre-spray, protector 
and other chemicals over large areas.  A specially designed valve injects chemical into the 
high-pressure water flow coming from the machine and automatically dilutes it at the 
desired ratio. A Hydro-Force injection sprayer can be used at pressures as low as 50 PSI or as 
high as 1,000 PSI. All Hydro-Force sprayers are set at the factory to be used at water pressures 
of 400 P.S.I. for a dilution ratio of 1:8, but can easily be configured to work at lower pressures 
by simply changing the metering tip (see Metering Instructions below). The water flow is 
automatically reduced as it passes through the injector valve, thus reducing the pressure 
approximately 64%. To obtain the actual working pressure of your Hydro-Force, multiply your 
incoming pressure by 36%. 