background image

Multi-Sprayer

•Carpet & Upholstery 

Pre & After Sprays 

•Ceiling Cleaning 

•Janitorial Sprays 

•Carpet Restoration 

Applications

Ideal For:

Disinfectants, Deo

-

Cleaners, Spotting 

Agents, Insecticides, 

Garden Agents & Fer

-

tilizers, Cleans Ducts, 

Ovens & Siding

Also Sprays:

OWNERS MANUAL

M1

M2

For Parts & Service Call:

www

.multi-sprayer.com

(Now also available in cordless recha

rgeable models)

APPROXIMATE RATE OF SPRAY FROM T-JETS & V-JETS 

USING 50 PSI PUMP:

TI

P

 SIZE

XX050

XX01

XX015

 

XX02

XX03

XX04

XX05

XX06

XX08

XX10

GAL

 per MIN

.055

.11

.16

.22

.33

.44

.55

.66

.88

1.10

XX - Degree of Arc of 

Spray.  Available from 0 

to 110 Degrees.

TROUBLE SHOOTING

Motor operates, but no spray:

 

• If you have M2 model, see “Getting Started” instructions    

 

  on Page 3 and on back of sprayer

 

• Restricted intake or discharge line. Clogged suction  

 

 

  strainer, kinked suction or spray hose, clogged spray tip,    

 

  broken or clogged trigger

 

• Air leak in suction hose

 

• Broken or worn pump parts; valve chamber, or diaphragm

Motor fails to run:

 

• Switch defective or loose wiring connection

 

• Defective motor

 

• Frozen cam bearing

 

• Partially clogged lines, strainers, tip or trigger

 

• Worn pump cam bearing (also excessive noise)

 

• Broken or worn pump parts; valve chamber or diaphragm

Leaking:

 

• Hole in hose, cracked pump housing, loose or broken  

 

 

  hose barb at pump inlet or outlet, loose or broken    

 

 

  hose clamp at pump inlet or outlet

Multi-Sprayer Systems, Inc.

4810 Park Glen Road, St. Louis Park, MN 55416

www.multi-sprayer.com | info@multi-sprayer.com

800-669-2469 | 952-767-3063

Page 8

MULTI-SPR

AYER DIAGRAM

Wands Shown on Page 6

Page 5

MULTI-SPR

AYER 

PARTS

KEY

*5

6

**

7

8

9

11

12

*14

15

16

17

18

19

20

21

22

23

24

25

PA

R

T#

BS

T

-1YSS

6590

6590-VIKIT

125HBL-4-4

FW

-10

SNP-2

N4MEB6

AQ115

216P-4-2

1

1375

ARD

16001

1E

UR33

13862-50

18110

SR7W

-2

2G

F17004LG

M22004LG

UR12.5

AQ115

LHA

VHA

UHA

DESCRIPTION

SSFemale Coupler, 1/8”

Brass/

V

iton 

T

rigger

T

rigger 

V

alve Repair Kit

Brass Hose Barb, 1/4” x 1/4”

Urethane Coiled Spray Hose 10” 1/4 ID

Hose Clamp, Nylon

Elbo

w

, Nylon

1

15V Motor & Pump

Brass Reducing Nipple, 1/4” / 1/8”

Rubber Hose Grommet

Base Plate Retainer Button

Electric On/O

f

f Switch

Urethane Suction Hose, 33”, 1/4 ID

Suction Hose Strainer, 50 mesh

Power Cord, 20 Feet

Power Cord Strain Relief

2 Gallon Solution Container

Female Jug QC

Male Jug QC, Cap and 90 Degree Barb

Urethane Dip 

T

ube, 12.5” 1/4 ID

1

15 

V

olt Pump Parts

Lower Head Assembl

y, 

T

riangular dia

-

phragm/CAM

V

alve Assembl

y, 3 Inlet and 2 Outlet 

V

alves

Black Poly Pump Head

*Parts #5 and #14 on M2 Model Only

If pump leaks from small triangle on black pump head, replace 

#UHA.  If pump runs but does not pump, replace VH

A

 and LHA.

Page 4

m1-11-17.indd   1

10/1/2012   11:05:12 AM

Multi-Sprayer

•Carpet & Upholstery 

Pre & After Sprays 

•Ceiling Cleaning 

•Janitorial Sprays 

•Carpet Restoration 

Applications

Ideal For:

Disinfectants, Deo

-

Cleaners, Spotting 

Agents, Insecticides, 

Garden Agents & Fer

-

tilizers, Cleans Ducts, 

Ovens & Siding

Also Sprays:

OWNERS MANUAL

M1

M2

For Parts & Service Call:

www

.multi-sprayer.com

(Now also available in cordless recha

rgeable models)

APPROXIMATE RATE OF SPRAY FROM T-JETS & V-JETS 

USING 50 PSI PUMP:

TI

P

 SIZE

XX050

XX01

XX015

 

XX02

XX03

XX04

XX05

XX06

XX08

XX10

GAL

 per MIN

.055

.11

.16

.22

.33

.44

.55

.66

.88

1.10

XX - Degree of Arc of 

Spray.  Available from 0 

to 110 Degrees.

TROUBLE SHOOTING

Motor operates, but no spray:

 

•If you have M2 model, see “Getting Started” instructions    

 

on Page 3 and on back of sprayer

 

•Restricted intake or discharge line.  Clogged suction  

 

 

strainer, kinked suction or spray hose, clogged spray tip,    

 

broken or clogged trigger

 

•Air leak in suction hose

 

•Broken or worn pump parts; valve chamber, or diaphragm

Motor fails to run:

 

•Switch defective or loose wiring connection

 

•Defective motor

 

•Frozen cam bearing

 

•Partially clogged lines, strainers, tip or trigger

 

•Worn pump cam bearing (also excessive noise)

 

•Broken or worn pump parts; valve chamber or diaphragm

Leaking:

 

•Hole in hose, cracked pump housing, loose or broken  

 

 

hose barb at pump inlet or outlet, loose or broken    

 

 

hose clamp at pump inlet or outlet

Multi-Sprayer Systems, Inc.

3515 Hennepin 

A

venue South

Minneapolis, MN 55408

info@multi-sprayer.com

800-669-2469 | 612-825-5354

Page 8

MULTI-SPR

AYER DIAGRAM

Wands Shown on Page 6

Page 5

MULTI-SPR

AYER 

PARTS

KEY

*5

6

**

7

8

11

12

*14

15

16

17

18

19

20

21

22

23

24

25

PA

R

T#

BS

T

-1YSS

6590

6590-VIKIT

H14-2MUSBR

FW

-10

N4MEB6

AQ115

216P-4-2

1

1375

ARD

16001

1E

UR33

13862-50

18110

SR7W

-2

2G

F17004LG

M22004LG

UR12.5

AQ115

LHA

VHA

UHA

DESCRIPTION

SSFemale Coupler, 1/8”

Brass/

V

iton 

T

rigger

T

rigger 

V

alve Repair Kit

Compression and Strain Relief

Urethane Coiled Spray Hose 10” 1/4 ID

Elbo

w

, Nylon

1

15V Motor & Pump

Brass Reducing Nipple, 1/4” / 1/8”

Rubber Hose Grommet

Base Plate Retainer Button

Electric On/O

f

f Switch

Urethane Suction Hose, 33”, 1/4 ID

Suction Hose Strainer, 50 mesh

Power Cord, 20 Feet

Power Cord Strain Relief

2 Gallon Solution Container

Female Jug QC

Male Jug QC, Cap and 90 Degree Barb

Urethane Dip 

T

ube, 12.5” 1/4 ID

**

M22

Male QC

1

15 

V

olt Pump Parts

Lower Head Assembl

y, 

T

riangular dia

-

phragm/CAM

V

alve Assembl

y, 3 Inlet and 2 Outlet 

V

alves

Black Poly Pump Head

*Parts #5 and #14 on M2 Model Only

If pump leaks from small triangle on black pump head, replace 

#UHA.  If pump runs but does not pump, replace VH

A

 and LHA.

Page 4

m1-11-17.indd   1

10/1/2012   11:05:12 AM

**

Cap & 90

Cap and 90 degree panel mount

• Male and/or female QC on jug failure

Summary of Contents for M1 Multi-Sprayer

Page 1: ... Service Call www multi sprayer com Now also available in cordless rechargeable models m m Multi Sprayer Carpet Upholstery Pre After Sprays Ceiling Cleaning Janitorial Sprays Carpet Restoration Applications Ideal For Disinfectants Deo Cleaners Spotting Agents Insecticides Garden Agents Fer tilizers Cleans Ducts Ovens Siding Also Sprays OWNERS MANUAL M1 M2 For Parts Service Call www multi sprayer c...

Page 2: ... SPRAY COM BUSTIBLE FLUIDS PLUG INTO 115 120 VOLT 50 60 CYCLE GROUNDED 3 PRONG RECEPTACLE Page 2 m1 11 17 indd 2 T A in B INTRODUCTION The Multi Sprayer replaces pump up sprayers The Multi Sprayer is a tough compact and versatile electric sprayer equipped with a SOLVENT COMPATIBLE VITON PUMP It was designed to be easily transported to the job taking up limited space On the job its 20 foot electric...

Page 3: ...ical compatibility Chemical damage to the pump is not covered by the warranty GETTING STARTED Page 3 e 5 5 GETTING STARTED Slant your 2 gallon container of solution into the Multi out connect the male female cap quick connect system Then push the container into the Multi Sprayer To remove container push the silver tab on the female quick connect tip out of container and remove Plug in turn on swit...

Page 4: ... black pump head replace UHA If pump runs but does not pump replace VHA and LHA Page 4 M MULTI SPRAYER PARTS KEY 5 6 7 8 11 12 14 15 16 17 18 19 20 21 22 23 24 25 PART BST 1YSS 6590 6590 VIKIT H14 2MUSBR FW 10 N4MEB6 AQ115 216P 4 2 11375 ARD 160011E UR33 13862 50 18110 SR7W 2 2G F17004LG M22004LG UR12 5 AQ115 LHA VHA UHA DESCRIPTION SSFemale Coupler 1 8 Brass Viton Trigger Trigger Valve Repair Kit...

Page 5: ...MULTI SPRAYER DIAGRAM Wands Shown on Page 6 Page 5 b MULTI SPRAYER DIAGRAM Wands Shown on Page 6 Page 5 b ...

Page 6: ...ge 6 1 2 3 2 1B 24 2A 25 1A 2 2A 3 25 G S o T c o P IF 1 q 2 th 3 s M A lo a c w Y ra p w S C tu p G M1 WAND KEY 1 2 3 PART H1 8DT 8004 SS20 AB110CA DESCRIPTION Female Thread Brass V Jet Nozzle Threaded S S Wand Tube Brass Hex Nipple 1 4 Male 1 8 Female M2 WANDS WAC WACS KEY 1A 2 2A 24 3 25 2 1B 24 2A 25 WAC TPU8004SS CP1325 CP1335 4193 A 10 50SS SS20 BST N1SS WACS CP1325 TPU50015 4193 A 20 50SS C...

Page 7: ...from inside of solution container compartment B Remove bottom plate to access pump Page 7 10 1 2012 11 05 12 AM TO REMOVE PUMP A Remove nylon tabs by tapping out from inside of solution container compartment B Remove bottom plate to access pump Page 7 ...

Page 8: ...5416 www multi sprayer com info multi sprayer com 800 669 2469 952 767 3063 Page 8 APPROXIMATE RATE OF SPRAY FROM T JETS V JETS USING 50 PSI PUMP TIP SIZE XX050 XX01 XX015 XX02 XX03 XX04 XX05 XX06 XX08 XX10 GAL per MIN 055 11 16 22 33 44 55 66 88 1 10 XX Degree of Arc of Spray Available from 0 to 110 Degrees TROUBLE SHOOTING Motor operates but no spray If you have M2 model see Getting Started inst...

Reviews: