background image

AccuDose Series Proportioner

 Models 38741GB & 38751GB

with E-Gap Eductors

Installation and Operation:

1. Remove cabinet cover. Drill holes for the three wall anchors with an 8mm drill bit, using the cabinet back as a template

for correct spacing of the mounting screws. Install mounting anchors, and then screws in top two anchors. Slide key
holes in cabinet back over screw heads, tighten screws, then install bottom screw. Do not mount more than 1.8 metres
above the bottom of the concentrate container, nor below the highest concentrate level (never mount your
concentrate higher than the proportioner).

2. Select metering tips (up to 4) for the selector valve. (see next two sections) Push each tip firmly into a separate hose

barb extending from the selector valve. A tip with no hole (clear plastic) can be used to block any valve port not being
used. (This may be used for dispensing water only).

3. Attach the chemical suction tube assembly to the selector valve, sliding the open end of each piece of tubing over

one barb on the valve. Make sure suction tubes are on the barb far enough to prevent air from leaking into tube.

4. Slip other end of supply tube through an opening in either side of the cabinet and slide a ceramic weight over the

tube, then push a footvalve into the end of the tube. (Repeat for all eductors.)

5. Place foot valve ends of supply tubes into concentrate containers. REMEMBER TO CHECK FOOT VALVE

STRAINERS PERIODICALLY FOR CLOGGING: CLEAN IF NECESSARY.

6. A short  discharge tube is used with the 4 LPM eductor; minimum tube length is 20cm for correct operation. Longer

tubes (1.2 m) are used with a 14 LPM eductor.  Do not remove the flooding rings from inside the tubes.  Slide end
of tube with flooding ring over eductor discharge outlet. (Repeat for all eductors.) Hooks may be installed on
longertubes to allow discharge tube to  hang from dispenser when not in use.

7. Replace cabinet cover. Push the sides in, behind the latch holes, to snap the cover in place. The two screws provided

may be installed in the holes in the cabinet sides to prevent easy removal of cover.

8. Connect water supply hose of at least 13mm ID to water inlet swivel. (Minimum 1.76 Bar pressure, with water running,

is required for correct operation.) Connect opposite end of hose to water supply. Turn water supply on.

9. Push button to start flow of desired water/concentrate solution, and hold until supply tube is primed (filled). Then push

the button whenever dispensing is desired, and release button to stop flow of solution.  If you wishto be able to lock
the button in the “on” position: clip or bend  the two tabs  behind the lower front portion of the button (see diagram).
This allows the button to be pushed fully in and so lock in the “on” position. 

To unlock, PULL THE BUTTON OUT

.

Package Should Contain:

1. Proportioner unit.
2. Supply tubing 6.4m total.
3. Foot valve assemblies & weights (5).
4. Discharge tubing for each eductor.
5. Metering tip kits.
6. Mounting anchor kit.
7. Hose hook for 14 LPM eductor.
8. Instruction sheet.

Clip or bend
these tabs to
depress
button into
locked
position.

Summary of Contents for AccuDose 38741GB

Page 1: ...ICALLY FOR CLOGGING CLEAN IF NECESSARY 6 A short discharge tube is used with the 4 LPM eductor minimum tube length is 20cm for correct operation Longer tubes 1 2 m are used with a 14 LPM eductor Do not remove the flooding rings from inside the tubes Slide end of tube with flooding ring over eductor discharge outlet Repeat for all eductors Hooks may be installed on longertubes to allow discharge tu...

Page 2: ...her 2 10082835 Swivel collar moulded 3 10082816 Swivel stem moulded 10075950 O ring two per nipple 4 10075925 Pipe plug 5 10080710 Button grey standard 10080711 Button sky blue 10080712 Button red 10080713 Button green 10080714 Button light grey 10080715 Button yellow 6 10080894 Cabinet 7 10020700 Selector valve grommet 10020900 Back up ring for grommet Key Description PartNo MeteringTipSelection ...

Page 3: ...ook sky blue 10080732 Hose hook red 10080733 Hose hook green 10080734 Hose hook light grey 10080735 Hose hook yellow Hose hooks are for 14 LPM discharge tubes 15 10080957 Selector replacement kit e support clip f Suction stub g O ring h selector valve assembly 16 690014 Metering tip kit 17 500870 Tubing 6mm x 2 1m 18 509900 Weight 19 10076301 Footvalve viton EPDM also available order 10076302 NOT ...

Page 4: ... i Selector out of position i Ensure selector is in desired position 3 Excess concentrate draw a Metering tip not in place a Press correct tip firmly into barb on selector valve b Chemical above eductor b Place concentrate below the eductor 4 Failure of unit to turn off a Water valve parts dirty or a Clean or replace with valve parts kit defective b Magnet does not fully return b Make sure magnet ...