INSTRUCTION MANUAL  

DEHUMIDIFIERS 

AADHC100P & AADHC60P

Summary of Contents for AADHC100P

Page 1: ...INSTRUCTION MANUAL DEHUMIDIFIERS AADHC100P AADHC60P ...

Page 2: ...ax condenser pressure 3 6 MPa 3 6 MPa Max evaporator pressure 1 2 MPa 1 2 MPa Freon type capacity R410a 390g R410a 400g Grade of waterproof IP X1 IP X1 Weight 73lbs 77lbs Operating ambient temperature 41 F 95 F 41 F 95 F Test conditions 86 F RH80 86 F RH80 WARNINGS Please follow the below safety guidelines when using the dehumidifier Unplug the power supply when cleaning or storing the unit Do not...

Page 3: ...pening for draining pipe Water tank handle Power cord PRODUCT DRAWINGS INSTRUCTION MANUAL FRONT FRONT OPEN BACK Outer cover Front cover Wheel Handle Control panel Power cord Front panel hinges Hot air vents Power cord ...

Page 4: ...e The end of the drainage pipe should not be higher than the water tank outlet If the drainage pipe end is higher than the outlet water will not drain properly and could damage components DRAINAGE INSTALLATION DRAINAGE WITH THE BUILT IN WATER TANK The unit is designed to use the built in water tank for drainage by default When the tank is full the screen will display FULL and also make a buzzing s...

Page 5: ... Press the POWER button to start the machine The screen will display Run and Current the present humidity Run 2 To set the desired humidity press the TIMER MODE button The screen shows Set and the machine enters into the set mode When in the set mode you can increase or decrease the humidity from the default setting to your desired level by using the or buttons Run Set ATTENTION The machine defaul...

Page 6: ...3 while the machine remains in the standby mode since it is within the 3 minute delay protection period This usually happens in the condition that the ambient humidity is high It is not a machine malfunction Timed dehumidifying operation to the desired humidity level When the timer is set the machine will operate according to the humidity set point see page 5 step 2 only after the Timing On time a...

Page 7: ...d Continuous Operation set points will not be remembered when power failure occurs They must be reset when the power is restored The Automatic Restart feature allows the unit to be used with controllers and timers On Off Delay If the system is turned off after running and you wish to turn it on again there is a 3 minute delay before restart as protection to the working components of the unit MAINT...

Page 8: ...ion Contactyourretailertoreplace thesensor Machinerunsbutdoes notdehumidify Thehumiditysetpointishigher thantheambienthumidity Resetthehumiditytoalowersetpoint orpoweroffthe machineifthedesiredhumiditylevelhasbeenreached Reduceddehumidifier capacity Filtermeshisjammed Cleanthefiltermeshaccordingtomanual Air inand orAir outlouversare jammed CleartheblockagefromAir inand orAir outlouvers Noairinlet ...