background image

965520 Rev. E

5/02

Package Contains:

1. Proportioner with U-clamp for mounting

2. Float with chain

3. Suction tube with foot valve -- 9 ft.

4. Discharge tube -- 2 ft.

5. Metering tip kit (14 tips)

6. Production information sheet

HydroMinder Model 511

protective clothing and eyewear when dispensing chemicals or other materials.
observe safety and handling instructions of the chemical manufacturers.
direct discharge away from you or other persons or into approved containers.
dispense cleaners and chemicals in accordance with manufacturer's instructions. Exercise

CAUTION

 when maintaining your equipment.

equipment clean for proper operation.
protective clothing and eyewear when working in the vicinity of all chemicals, filling or emptying

equipment or changing metering tips.
re-assemble equipment according to instruction procedures. Be sure all components are firmly

screwed or latched into position.
only to tap water outlets (85 PSI maximum).

WEAR

THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS

Hydro Systems manufactures quality chemical proportioners. Please use this equipment carefully and observe all

warnings and cautions.

****************************************************************

NOTE

 ************************************************************

ALWAYS
ALWAYS
ALWAYS

KEEP

WEAR

ALWAYS

ATTACH

Through proper care and maintenance, this equipment will serve your toughest cleaning jobs.

Installation:

1. Mount the unit in a level position on the side of a reservoir. The U-clamp may be repositioned or removed as necessary.

2. Install a minimum ½" ID water hose between the inlet threads and the water spigot. Minimum water pressure required

to properly operate the proportioner is 25 PSI (flowing).

3. Attach the end of the discharge tube with the clamp and flooding ring to the discharge barb on the eductor.

4. Insert the foot valve end of the suction tube into the concentrate container. (The level of the concentrate must be below

the level of the eductor, or the proportioner will continue to siphon concentrate after it is turned "off".)

5. Select a metering tip (see next two sections) and screw it into the suction stub on the eductor body.

6. Slide the open end of the suction tube over the suction stub.

7. Adjust the bead chain length to position the float at the desired level of solution. To prevent foaming, be certain that the

solution level will always be above the point of discharge. Be sure float mechanism is not hampered by water turbulence

caused by discharging solution. It may be necessary to baffle the float from the discharge in order for the unit to work

properly.

Metering Tip Selection:

The final concentration of the dispensed liquid is related to both the size of the metering tip opening (orifice) and the viscosity

of  the  liquid  being  siphoned.  If  product  viscosity  is  noticeably  greater  than  that  of  water,  consult  the  procedure  for

Measurement of Concentration on the next page to achieve your desired water-to-product ratio. For water-thin products,

use the chart below as a guideline. Because such factors as inlet water pressure and temperature can affect dilution ratios,

the figures listed below are only approximate. Test the actual dilution you are achieving using the Measurement of

Concentration procedure for best results. Two undrilled, clear tips are supplied for drilling sizes not listed.

Approx. Ratio @ 40 PSI,

 Tip Color

Drill Size

   water-thin viscosity

No tip

4:1

Gray

30

5:1

Black

40

6:1

Beige

50

8:1

Red

55

17:1

White

57

23:1

Blue

60

25:1

Tan

65

36:1

Green

70

48:1

Orange

72

64:1

Brown

74

75:1

Yellow

76

90:1

Purple

80

120:1

Pink

87

240:1

Approx. Ratio @ 40 PSI,

Tip Color

Drill Size

   water-thin viscosity

Reviews: