background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Operation / Installation Instructions 

 
 
 
 
 
 
 
 
 
 
 

HEATMAX

ELECTRIC POOL AND SPA HEATER

MODELS:

HEATMAX  RHS-5.5KW

5500W HEATER

HEATMAX  RHS-11.0KW

11,000W HEATER

Summary of Contents for HEATMAX Series

Page 1: ...Operation Installation Instructions HEATMAX ELECTRIC POOL AND SPA HEATER MODELS HEATMAX RHS 5 5KW 5500W HEATER HEATMAX RHS 11 0KW 11 000W HEATER ...

Page 2: ......

Page 3: ... 1 a reinforced concrete slab for support 2 a ground plate provided beneath the hot tub or spa or 3 a permanent ground connection that is acceptable to the local inspection authority DANGER RISK OF ELECTRICAL SHOCK Do Not permit any electrical appliance such as a light telephone radio or television within 5 feet 1 5m of a spa or hot tub To reduce the risk of injury a The water in a spa or hot tub ...

Page 4: ...hermostat are intended for reference points only They do not reflect the actual temperature of the water Make small adjustments until the desired temperature is achieved Allow several hours between adjustments for the temperature to stabilize Use an accurate thermometer to monitor the water temperature HIGH LIMIT The purpose of this switch is to shut off the heater if the water temperature reaches...

Page 5: ... the potential for electrical hazard and may void the warranty CAUTION Use only approved pressure type wire splicing or connectors suitable for the size and type of wiring used 240 VOLT INSTALLATION 1 Provide the proper voltage and circuit from the service panel as detailed above 2 Open the access panel on the RHS control box to expose wire connections 3 Using copper conductors only connect input ...

Page 6: ...ment of the pressure switch Follow the system start up procedures leaving the thermostat in the OFF position CAUTION Remove all power to the unit prior to completing the steps below WATER LEVEL INSTALLATION LEVEL FT WATER WEIGHT LB 1 Shut off power to the HEATMAX System Pump prior to attempting any adjustments to the pressure switch 2 Remove wires from pressure switch terminals 3 Place an Ohm mete...

Page 7: ...rial and workmanship for a period of two year from the date of purchase HYDROQUIP will repair or replace the part which in our opinion is defective This warranty excludes damage as a result of normal wear freezing low voltage chemical abuse accident negligence alteration improper installation use or care This warranty does not extend to and is void for any products that are used in non residential...

Page 8: ...85 0116 Rev 5 02 18 ...