Installation Instructions

 

MX3431

Smart DC Remote Power Supply

The HySecurity Smart DC Remote Power Supply provides an optional power 

source for Smart DC gate operators that are configured for solar-power. The kit 

converts high voltage AC power into low voltage DC power which eliminates the 

need for solar panels. Low voltage wire is run out to the gate operator while the 

power supply remains in garage or shed plugged into the AC power source.

NOTE:

  To install the Smart DC operator on site, follow the separate installation 

instructions that accompany the gate operator.

To install the Smart DC Remote Power Supply, review the illustrations and the 

steps found on the following pages.

Tools required

•  Pliers for crimping
•  Wire cutter

Power Cable and Wire Connections

Follow the steps to secure power connections. Wire size and appropriate distance 

run to operator is shown in Table 1.

NOTE:

  The Smart DC Remote Power Supply must be located in a cool, dry location. 

Examples include: Off the floor in a garage or inside a weather tight shed. 

Table 1: Wire Size to Maximum Run

Wire size* 

Maximum Run 

100% Duty Cycle

Maximum Run 

50% Duty Cycle

Voltage Rating  

for Direct Buried Cable

12 AWG

400 ft (122 m)

800 ft (244 m)

300V

14 AWG

250 ft (76 m)

500 ft (152 m)

300V

16 AWG

175 ft (53 m)

350 ft (107 m)

300V

*Other cable sizes not recommended.

12

1

Run a “two conductor” power cable from the 

Smart DC Remote Power Supply location to the 

HySecurity Smart DC gate operator.

SwingSmart operator 

shown as reference only.

Trench and install in-ground cable. 
To protect cable wire, conduit is 
recommended.

Output of power supply internally set to 48VDC. 

No adjustment can be made.