background image

                                                                                                                                                                                                                         

 

 

1

  / 

12

 

Document No.

HIM-13010 

Confidential C

 

                                                                           

I-PEX Inc.

                                                                     

QKE-DFFDE09-03 REV.8

 

 
 
 

 
 
 
 
 

 

 
 
 
 
 

CABLINE

®

-VSF CONN. 

Part No.PLUG: 20645-0**T-01,3049-0**1 RECEPTACLE:

 

20455-0**E-

※※※

 

 

Instruction Manual

 

 

 

 

 

 

 

2

 

S14534

 

December 22, 2014 

H.A

 

 

E.K

 

1

 

S14257

 

June 30, 2014 

H.I

 

 

E.K

 

0

 

S13474

 

December 10, 2013 

H.Aoki 

J.Tateishi 

E.Kawabe 

Rev. 

ECN 

Date 

Prepared by 

Checked by 

Approved by 

Summary of Contents for CABLINE-VSF

Page 1: ...3 REV 8 CABLINE VSF CONN Part No PLUG 20645 0 T 01 3049 0 1 RECEPTACLE 20455 0 E Instruction Manual 2 S14534 December 22 2014 H A E K 1 S14257 June 30 2014 H I E K 0 S13474 December 10 2013 H Aoki J T...

Page 2: ...E VSF PLUG Part No 20645 0 T 01 SHELL ASS Y With LOCK BAR 3049 0 1 SHELL Without LOCK BAR Fig 1 SHELLASS Y With LOCK BAR Fig 2 SHELL Without LOCK BAR FPC assembly state FPC assembly state PCB side con...

Page 3: ...matched 3 Fig 3 2 How to mate 4 FPC As shown in Fig 4 push FPC horizontally until it is locked 4 Fig 4 SHELL LOCK BAR For the connector SHELL Without LOCK BAR FPC Insert FPC to the connector horizont...

Page 4: ...NE VSF CONN Instruction Manual Document No HIM 13010 4 12 Confidential C Cautions 5 When you push one end it might cause half mating Fig 5 5 Fig 5 NG There is gap NG 1 Push the one side 2 Push the one...

Page 5: ...er there is space between mating confirmation surfaces 6 Fig 6 LOCK BAR SHELL After mated push LOCK BAR to the PCB side and lock it to SHELL of the PCB side connector 7 Fig 7 Contents of confirmation...

Page 6: ...OCK BAR When mating in case you mate the connector pushing LOCK BAR as shown in Fig 10 there are possibilities to cause LOCK BAR deformation or the rotation axis dropping out from the connector Please...

Page 7: ...ow When you push only one side at the temporary insert condition maximum slanted degree have to be less than 5 Deformation of the connector doesn t occur if insertion angle is kept less than 5 degree...

Page 8: ...ed un mating might cause deformations of FPC or damage on FPC pattern OK horizontal un mating OK condition 11 Fig 11 NG Slanted un mating NG 5 To use this connector safely please withdraw plug up to a...

Page 9: ...described in Fig 11 Caution Except for part if you pull up the LOCK BAR towards direction LOCK BAR would have deformation or the connector would have damage Also if you use Insulated part of LOCK BAR...

Page 10: ...13 As Fig 14 please make un mating by pulling the horizontal part in parallel to PCB Caution Except for part if you pull up the LOCK BAR towards direction LOCK BAR would have deformation or the connec...

Page 11: ...C is pulled to the vertical direction or slanted direction SHELL of the receptacle connector can deform or FPC might pull out from plug Please don t pull FPC vertically or with slanted angle LOCK BAR...

Page 12: ...too much pulling force to FPC Please refrain from applying pulling force or repeated bending force to the FPC assembly part of a plug connector 15 Fig 15 16 FPC Please refrain from applying cable ret...