background image

i

Specifications:-

 

 

 

b) Output LED

 

 

                 i) T - Time LED

   

Display

   

6 Digit 7 segment LED

 

                                 b) Buzzer Output

Range

 

 

:

 

Ref. SET Mode

 

 

 

c) Status LED

Supply

   

:

 

90 to 270 VAC

Sensor Supply

 

:

 

12VDC (+10%) @ 30mA

Mounting

  

:

 

Panel

 

LED Indication

 

:

             

 a) Mode LED

 

 

 

i)B - Batch, ii) L - Length, iii) P - Preset

 

 

 

 

 i) 1 - Output 1, ii) 2 - Output 2

Outputs

   

:

 

a) Two 5Amp @ 230VAC Relay

Accuracy 

:

 

0.05% Full Scale

Memory

   

:

 

Non-Volatile (Flash)

Memory Retention:

 

Up to 10 years

Housing

   

:

 

ABS Plastic

Humidity

  

:

 

95% RN(Non Condensing)

Operating Temp.

 

:

 

0 ~ 55°C

Mechanical

 

:

  

See Table:1 (On Page 2)  

Operating Mode

 

:

              a) Mode 1

Dimension

 

 

 

 

c) Preset Type

Configuration Parameters:-

 

 

 

b) Mode 2 

Output 2 Function  :

              a) As 2nd Set Point

 

 

 

c) As Auxiliary Output

Leading Zero

 

:

 

Enable / Disable (Selective)

Count Mode

 

:

              a) Batch Type

Front Reset

 

:

 

Enable / Disable (Selective)

 

 

 

b) As Batch Output

Input Frequency

  

:

              a) Very Low 

b) Low

 

 

 

c) Medium 

 d) High

 

 

 

e) Very High

 

 

 

d) Output is Off

 

 

 

b) Length Type

User Lock

 

:

 

It can be Set Between 1 to 9999 

USER’S  OPERATING  MANUAL  FOR  BATCH,   LENGTH  &  PRESET   COUNTER

(Models :BL-886) 

ELECTRICAL

v

The  controller  must  be  wired  as  per  wiring  diagram  &  it  must   

comply with local electrical regulation.

v

  The  controller  is  generally  part  of  control  panel  and  in  such  a   

case  the  terminals  should  not  remain  accessible  to  the  user  after 
installation.

v

The  controller  in  its  installed  state  must  be  protected  against   

e x c e s s i v e  e l e c t r o s t a t i c  o r  e l e c t r o m a g n e t i c  i n t e r f e r e n c e s .   

 

Ventilation holes provided on the chassis of the instrument are meant 
for thermal dissipation hence should not be obstructed in the panel.

GENERAL

v

Care  must  be  taken  not  to  connect  AC  supplies  to  low  voltage   

sensor input.

v

The  Controller  in  its  installed  state  should  not  be  exposed  to   

carbon dust, salt  air, direct sunlight or radiant  heat.

v

Circuit    breaker    and    appropriate    fuses    must  be  used  for   

driving  high  voltage  loads  to  protect  the  controller  from  any  possible 
damage due to short circuit on loads.

v

To  minimize  pickup  of  electrical  noise,  the  wiring  for  low     

voltage  DC  and  sensor  input  must  be  routed  away  from  high   
current power cables. Where it is impractical to do this, use shielded 
ground at both ends.

v

  The  controller  must  be  configured  correctly  for  intended     

operation.  Incorrect  configuration  could  result  in  damage  to  the 
equipment  or  the  process  under  control  or  it  may  lead  personnel 
injury.

MECHANICAL

v

The  Controller  in  its  installed  state  must  not  come  in  close   

proximity  to  any  corrosive/combustible  gases,  caustic  vapors,  oils, 
steam or any other process by products.

This controller is meant for Batch & Length counter applications. It is 
important  to  read  the  manual  prior  to  installing  or  commissioning  of 
controller. All safety related instruction appearing in this manual must 
be followed to ensure safety of the operating personnel as well as the 
instrument.

v

Circuit  breaker  or  mains  s/w  with  fuse  (275V/1A)  must  be   

 

installed  between  power  supply  and  supply  terminals  to  protect  the 
controller from any possible damage due to high  

voltage  surges  of 

extended  duration.

v

The Electrical noise generated by switching inductive loads  might 

create momentary Fluctuation in display, alarm latch  

up,  data  loss 

or  permanent  damage  to  the  instrument. To  reduce  this  use  snubber 
circuit across  the load.

SAFETY INSTRUCTION

v

Ambient  temperature  and  relative  humidity  surrounding  the   

controller  must  not  exceed  the  maximum  specified  limit    for  proper 
operation of the controller.

v

The  controller  should  not  be  wired  to  a  3-Phase  supply  with   

unearthed star connection. Under fault condition such supply  

could 

rise above 264 VAC which will damage the controller.

1

OIM BL-886 V1.2 Page 1 of 6

BL - 886 

Display height (PV)

Model no.

White

Display Colour

0.56”

BL-886

Reviews: