background image

MAJ   :   16.09.11   

   

   

1   

 

 

 

THERMOSTAT 
I WARM 760 
 
OPERATION MANUAL 

 
 
 
Content 

Important information for safe usage 

Introduction 

Function 

 

Controls and display   

Buttons 

 

Start-up of the thermostat 

 

Menu structure of the thermostat 

Basic settings  

Set the language 

 

Set the date and the time 

Daily program 

Setting the daily program 

 

Weekly program 

 

Setting the weekly program   

Control of the heating system operating conditions  

Setting of the common parameters of the thermostat 

 

Output of energy saving statistics data 

 

Warranty 

 

Apendix 

 

Delivery set 

Installation manual 

 

Tools and materials required for thermostat installation: 

 

Installation of floor-mounting temperature sensor 

Thermostat installation 

Preparation of electrical connections 

 

Connection diagram   

Installation of the Thermostat 

Technical data 

 
 

Important information for safe usage 
 

Thermostat:  

Manufacturer's guarantee does not cover malfunctions caused by mechanical damage, improper installation, or exploitation for 
purposes,  or  under  conditions,  not  provided  by  the  User-  and  Installation  Manual.  Please  keep  in  mind  that  the  Installation 
Manual and the Connection Diagram are no replacement for the professional skill of the device installer.  
We  recommand  that  you  apply  for  professional  service  for  the  thermostat  and  heating  system  installation.  Only  qualified 
electricians should perform the connections and power networking of the device. Switch off power before connecting wiring to 
the thermostat or disconnecting the device for testing .  
Start-up: Don't turn the newly built heating system on before the tile fixing mixture or cement -sand mortar layer are hardened. 
You  can  get  the  different  hardening  times  from  the  manufacturer  of  your  chosen  building  material.  Turning  on  the  heating 
system prematurely can lead to damage of the floor decorative cover and heating mats, or sections outage. In case of doubt 
contact your dealer or heating system manufacturer. 
 

Introduction  

Thank  you  for  choosing  the 

I-WARM  760© 

electronic  regulation  device,  the  new  intelligent  heating  control  system.  With  this 

product you will see how easy it is to maintain your comfort at a lower cost; it will take care of keeping your home warm and 
cozy all the time. Designed with innovation and inspiration, the new thermostat is highly reliable, and easy to set and use. 
Separate settings can be programmed for different times of the day, whether or in or out. This unit allows programming in half 
hour time periods over a seven day period providing maximum operating choice. 
 

Before you start the installation, please read this manual carefully! 
 
 
 
 

Summary of Contents for 760

Page 1: ...l skill of the device installer We recommand that you apply for professional service for the thermostat and heating system installation Only qualified electricians should perform the connections and power networking of the device Switch off power before connecting wiring to the thermostat or disconnecting the device for testing Start up Don t turn the newly built heating system on before the tile ...

Page 2: ...display Start up of the thermostat The thermostat can be turned on after wiring connections are complete and tested To turn the I WARM 760 ON OFF press the middle button for not less than 3 seconds Turning ON OFF is accompanied by an appropriate animation on the display After the I WARM 760 is turned on the basic indication appears on the highlighted display The larger numbers 20 C indicate the ac...

Page 3: ...rm the settings until the device will return to the main Menu To return to the basic indication choose the submenu Save settings and exit and press the Menu button Set the date and the time Entering the correct date and time ensures the correct operation in the daily and the weekly program modes To set the date and time press the Menu button while in the basic mode and choose the Set date and time...

Page 4: ...change them Setting the daily program To set the daily mode press the menu button to access the daily program while the thermostat operates in the main mode Browse by using the selection buttons to the subdivision program setting then press the menu button Then select the Program day item and press the menu button The submenu Program day appears Activate is for starting the daily mode with prior s...

Page 5: ...s while the thermostat operates in the main mode Activate the subdivision program settings with the menu button Then select the Program week item and press the menu button The submenu Program week appears Activate is for starting the weekly mode with prior set parameters The view item allows you to view the heating diagram without being able to edit it The edit item enables you to set a heating sc...

Page 6: ...r heating program within one minute the device will return to operate in the previously chosen mode the data you entered will not be saved Control of the heating system operating conditions The I WARM 760 thermostat permanently controls the operating condition of the heating system If the heating of the floor surface to the preset temperature appears to be impossible the ATTENTION sign is displaye...

Page 7: ...Save settings and exit and press the menu button The I WARM 760 will return to its current operation and indication mode Warranty During the warranty period the customer has the right to get the product repaired or replaced due to faulty materials from the manufacturer on the condition that the manual guides to Installation and Operation of this device have been followed The warranty policy does n...

Page 8: ...e in the floor and lead its other end to the place chosen for the thermostat or junction box location Thermostat installation Preparation of electrical connections Install the plastic junction box into the wall where the location of the thermostat is planned Lead the power supply cable the cold leads of the heating mat or section and the temperature sensor cable into the box First of all disassemb...

Page 9: ... sensor connection cable 2 m Allowable ambient air temperature 5 up to 45 C Allowable relative air humidity 80 Maintaining temperature range 5 up to 35 N Factory preset 25 N ACCEPTANCE TEST CERTIFICATE The thermostat I Warm 760 passed the test Name Street ZIP code city Country Phone E Mail Date of purchase Installer Installation date Signature installer If you have questions please contact INNOV H...