background image

INSTALLATION

LD16 encoder is built in a 1U chassis for convenient rackmount installation.
Follow safety precautions when selecting installation location for your LD16 encoder. 

1.  Using supplied screws to secure the provided rack brackets to the LD16 unit, then 

install your LD16 encoder into the server rack.

2.  Make sure the Power Switch is in the OFF position.
3.  Connect your HD-analog or CVBS analog inputs to the 16 BNC connectors on the 

encoder.

4.  Plug in the network cable into the LAN connector on the rear panel of the encoder 

and then plug it into the Gigabit switch.

5.  Connect the provided 12V power supply to the 12V DC Power Supply connector and 

then plug in the supplied Power Cable into the provided power supply.

6.  Plug the power cable into the power source. Use of the UPS (Uninterrupted Power 

Supply) is highly recommended by i3 for added reliability and longevity of your encoder.

7.  Return the Power Switch into the ON position. The encoder will power on and the 

front panel LEDs turn on.

LD16

16-channel Encoder

Quick Start Guide

i3-TRNG-ENCR-

LD16

.indd

QR Code for 

Documentation & ACT

Scan this QR code or visit 

ftp.i3international.com

 to view 

and download 

Annexxus Configuration Tool v2.1.2.19

.  

 

Contact our Technical Support team at: 

1.877.877.7241 

or

 

support@i3international.com

 if you have any questions 

or concerns regarding camera installation or if you require 

software services or support.

ENCODER PARTS AND DEFINITIONS

Thank you for purchasing i3 International’s LD16 16-channel encoder. Your encoder is 

compatible with HD-TVI, HD-AHD, HD-CVI and CVBS analog inputs. 

To pair with SRX-Pro software, purchase enough analog licenses, which can be purchased 

individually or in bundles of 4.

SAFETY

When installing your LD16 encoder be sure to avoid:

•  excessive heat, such as direct sunlight or heating appliances

•  contaminants such as dust and smoke

•  strong magnetic fields

•  moisture and humidity

•  areas with mechanical vibrations

•  temperatures below -10°C (14°F) and above 50°C (122°F).

POWER SUPPLY

Power requirement: 110-120VAC, up to 20W. 

Power adapter (12VDC/5A) included.

Ensure the supplied voltage meets the power consumption requirements of this encoder 

before powering the encoder on. Incorrect voltage may cause irreparable damage to the 

device and will effectively void the encoder warranty.

SERVICING

To avoid electrical shock and to preserve the product warranty, DO NOT disassemble the 

encoder. Refer servicing to qualified personnel only.

PACKAGE CONTENTS

Ensure that the items received match those listed on the order form and the packing 

slip. In addition to this manual and a fully assembled encoder, the encoder packing box 

includes:

1.  12V DC Power Supply adapter

2.  Power Cable

3.  Rackmount brackets (2 pcs) with screws (4 pcs). 

Attach to the encoder if installing into a server rack.

No. Active Component Description

1

VIDEO IN

16 x BNC connectors for HD analog or CVBS inputs

2

LAN2

CAT5 LAN connection. Connect to the switch or to 

the NIC card on the Media Control Centre.

3

LAN1

Not in use. CAT5 WAN connection. 

4

12V Power Input

12V DC Power Supply connector (included)

5

Power Switch

Power switch for turning encoder ON/OFF

6

GND

Ground

CONNECTING LD16 ENCODER TO i3 SRX-PRO SERVER

SRX-Pro Server is capable of supporting up to 4 (four) LD16 encoders.

Each encoder supports up to 16 HD-analog or CVBS analog inputs, however, the number 

of inputs that can be added to the SRX-Pro Server is determined by the number of 

purchased licenses. When purchasing LD16 encoder, make sure to purchase enough 

“Analog Channel” licenses to support all your HD-analog or CVBS cameras.

When purchasing LD16 encoders together with an i3 Server, the NVR will be equipped 

with a single or dual PCI NIC card, respectively. Connect the encoders to the single or 

dual PCI NIC card labeled “LD16” (not the on-board NIC) on your NVR.

When purchasing more than 2 LD16 encoders together with a single i3 Server, connect 

2 encoders to the PCI NIC card labeled “LD16” and the remainder of the encoders - to 

an i3-recommended Gigabit switch.

If purchasing separately from i3 NVR, connect all encoders to the switch.

i3 SRX-Pro Media 

Control Centre

Connection Type 1

(when purchasing 1-2 LD16 together with NVR):

Connection Type 3

(when purchasing LD16 separately from NVR):

CAT5e/6

1

2 3

5 6

Note: Unmarked components are not in use.

CAT5e/6

Connection Type 2

(when purchasing 3-4 LD16 together with NVR):

LAN

Via Gigabit Switch

CAT5e/6

CAT5e/6

LAN

Via Gigabit Switch

Rev. 230721

1

2

3

4

5

6

7

8

16

15

14

13

12

11

10

9

4

     i3 SRX-Pro Media 

Control Centre

     i3 SRX-Pro Media 

Control Centre

Reviews: